    Www.2n.Cz version 2n ® helios ip force security ip intercom installation manual 2.1.

  • Page 2: Content

    The 2n telekomunikace a.S. Is a czech manufacturer and supplier of telecommunications equipment. The product family developed by 2n telekomunikace a.S. Includes gsm gateways, private branch exchanges (pbx), and door and lift communicators. 2n telekomunikace a.S. Has been ranked among the czech top c...

  • Page 3: Content

    Content 1. Product overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 1.1 components and associated products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 1.2 terms and symbols . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 4: 1. Product Overview

    4 2n telekomunikace a.S., www.2n.Cz ® 1. Product overview here is what you can find in this section: 1.1 components and associated products 1.2 terms and symbols basic features 2n ® helios ip force is a highly resistant and reliable ip door access intercom provided with a lot of useful above-standar...

  • Page 5: Advantages of Use

    5 2n telekomunikace a.S., www.2n.Cz ® 2n ® helios ip force can also be provided with rfid card reader modules. 2n ® helios ip force is very easy to install. All you have to do is connect the system into your lan via a network cable and feed it from a 12 v power supply or your poe supporting lan. Con...

  • Page 6: Basic Units

    6 2n telekomunikace a.S., www.2n.Cz ® 1.1 components and associated products components and associated products: 2n ® helios ip force basic units part no. 9151101 1 button part no. 9151101c 1 button with camera 9151101w part no. 1 button, 10 w loudspeaker, ip69k part no. 9151101cw 1 button with came...

  • Page 7

    7 2n telekomunikace a.S., www.2n.Cz ® part no. 9151101kw 1 button with keypad, 10 w loudspeaker, ip69k part no. 9151102r 2 buttons, card reader ready part no. 9151102cr 2 buttons with camera, card reader ready part no. 9151102crw 2 buttons with camera, card reader ready, 10 w loudspeaker, ip69k part...

  • Page 8: Flush Mounting Box

    8 2n telekomunikace a.S., www.2n.Cz ® flush mounting box 9151001 part no. Brick flush mounting box 9151002 part no. Plasterboard flush mounting box voip telephones 91378351 part no. Grandstream gxv3140 voip video telephone 91378354 part no. Grandstream gxv3175 voip telephone electric locks 932070e p...

  • Page 9: Power Supply

    9 2n telekomunikace a.S., www.2n.Cz ® power supply part no. 91378100e part no. 91378100us poe injector 91341481e part no. Adapter 12 v / 2 a a stabilised power supply has to be used if the ethernet (poe) power supply is not available. Part no. 932928e 12 v transformer additional modules 9151010 part...

  • Page 10

    10 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 11: 1.2 Terms and Symbols

    11 2n telekomunikace a.S., www.2n.Cz ® 1.2 terms and symbols the following symbols and pictograms are used in the manual: safety abide by this information to prevent persons from injury. Always warning abide by this information to prevent damage to the device. Always caution important information fo...

  • Page 12

    12 2n telekomunikace a.S., www.2n.Cz ® 2. Description and installation here is what you can find in this section: 2.1 before you start 2.2 mechanical installation 2.3 electric installation 2.4 extending module connection 2.5 button tags.

  • Page 13: 2.1 Before You Start

    13 2n telekomunikace a.S., www.2n.Cz ® 2.1 before you start product completeness check before you start please check the contents of your delivery: 2n ® helios ip force 1× 2n ® helios ip force 1× frame (of the corresponding colour) 1× torx 10 / torx 20 double-ended wrench bushings (enclosed): 1× big...

  • Page 14: 2.2 Mechanical Installation

    14 2n telekomunikace a.S., www.2n.Cz ® 2.2 mechanical installation mounting type overview refer below for a list of mounting types and necessary components. Flush mounting – classic bricks what you need: a precisely cut hole or, optionally, the brick flush mounting box, part no. 9151001 hole: (132 ×...

  • Page 15: Common Mounting Principles

    15 2n telekomunikace a.S., www.2n.Cz ® wall mounting (concrete and steel structures, entry barrier columns, etc.) what you need: just your unit 2n ® helios ip force common mounting principles caution the warranty does not apply to the product defects and failures arisen as a result of improper mount...

  • Page 16

    16 2n telekomunikace a.S., www.2n.Cz ® flush mounting – classic bricks if you use the brick flush mounting box, follow the instructions included in the box. If you do not use the mounting box, follow the instructions below: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. Make a hole using the template. Suppose that ...

  • Page 17

    17 2n telekomunikace a.S., www.2n.Cz ® flush mounting – thermally insulated wall cut out the thermal insulation layer using the template (the same as for classic brick wall). Suppose that all the required cables have been carried into the drilled hole. Now follow the instructions applicable for clas...

  • Page 18: Wall Mounting

    18 2n telekomunikace a.S., www.2n.Cz ® flush mounting – hollow bricks suppose you intend to install your unit into a wall made of 2n ® helios ip force hollow bricks. Note that the external side of the bricks gets damaged by cutting and the dowels cannot practically be fixed into the thin internal pa...

  • Page 19

    19 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 4. 5. 6. Select position with respect to the supply cables. Where the cables are installed inside a structure or wall, use the hole at the intercom bottom. Drill holes of the depth of 70 mm for dowels in the wall as shown in the figure. Push or hammer ...

  • Page 20: 2.3 Electric Installation

    20 2n telekomunikace a.S., www.2n.Cz ® 2.3 electric installation this subsection describes how to connect into your local area 2n ® helios ip force network (lan) and how to connect supply voltage and the electric lock. Pcb connectors picture shows the lay-out of connectors on the printed circuit 2n ...

  • Page 21

    21 2n telekomunikace a.S., www.2n.Cz ® connectors, pcb version 555v2 figure: 2n ® helios ip force.

  • Page 22: Lan Connection

    22 2n telekomunikace a.S., www.2n.Cz ® connectors, pcb version 555v3 figure: 2n ® helios ip force lan connection 2n ® is connected to the lan via a rj-45 terminated (connector x11) helios ip force utp/stp cable (of category cat 5e or higher). The system is equipped with the auto-mdix function and so...

  • Page 23: Electric Lock Connection

    23 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 4. 5. 6. External power supply an external 12 v power supply is connected to terminal block x19. Use a 12 v ± 15 % dc power source dimensioned to current intake of 2 a at least (part no. 91341481e) to ensure a reliable function of your device. Poe supp...

  • Page 24: Mounting Completion

    24 2n telekomunikace a.S., www.2n.Cz ® 1. 2. Normal operation default setup configuration jumpers x6, pcb version 555v2 figure: mounting completion having connected all the wires, make sure that the bushings, if used, are tightened properly and the rj-45 connector is inserted in the pcb connector. R...

  • Page 25: Additional Switch

    25 2n telekomunikace a.S., www.2n.Cz ® 2.4 extending module connection 2n ® helios ip force allows to connect following extending modules: additional switch internal rfid card reader 125 khz internal rfid card reader 13.56 mhz security relay wiegand isolator additional switch the (part no. 9151010) ...

  • Page 26

    26 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. A. B. C. 4. 5. 6. 7. A. B. C. 8. 9. Module mounting: switch off the intercom. Remove the front panel from the intercom. According to your model if you are mounting the switch into a two-nameplate model, demount the button pcb (1) and remove the right-h...

  • Page 27

    27 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 28

    28 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 29

    29 2n telekomunikace a.S., www.2n.Cz ® module settings: refer to the for details. 2n helios ip configuration manual ® connection: internal rfid card reader 125 khz the (part no. 9151011) is used for reading internal rfid card reader 125 khz rfid card ids in the 125 khz band. This module is intended ...

  • Page 30

    30 2n telekomunikace a.S., www.2n.Cz ® specifications: card reader compatible with em4100 / em4102 / hid prox rfid cards ® operating frequency: 125 khz minimum reading distance: 10 mm above cover 2n ® helios ip force relay output switching contact 30 v / 2a ac/dc active output 12 v / 700 ma transist...

  • Page 31

    31 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Mounting guide: switch off the intercom. Remove the front panel (7) from the intercom. Mount antenna board (8). Use two enclosed self tapping screws (9). Plug enclosed cable (11) to the antenna board connector. Dem...

  • Page 32

    32 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 33

    33 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 34

    34 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 35

    35 2n telekomunikace a.S., www.2n.Cz ® module setting: refer to the for details of wiegand, outputs 2n helios ip configuration manual ® and reader. Refer to the 2n ® for details of input, red helios ip automation manual led and tamper function and use. Connection:.

  • Page 36

    36 2n telekomunikace a.S., www.2n.Cz ® internal rfid card reader 13.56 mhz the (part no. 9151016) is used for reading internal rfid card reader 13.56 mhz rfid card ids in the 13.56 mhz band. This module is intended for mounting into the model 9151102cr, 9151102r, 9151101crp and 9151101rp. 2n ® helio...

  • Page 37

    37 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. Passive mode – requires external contact only (jp2 jumper on) u = approx. 8.3 v in1 u = approx. 8.3 v in2 i = approx. 0.5 ma loop signalling output internal red led under reader window pwr for external rfid card re...

  • Page 38

    38 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 39

    39 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 40

    40 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 41

    41 2n telekomunikace a.S., www.2n.Cz ® module setting: refer to the for details of wiegand, outputs 2n helios ip configuration manual ® and reader. Refer to the for details of input, red 2n ® helios ip automation manual led and tamper function and use. Connection:.

  • Page 42: Security Relay

    42 2n telekomunikace a.S., www.2n.Cz ® security relay the (part no. 9159010) is used for enhancing security between the security relay intercom and the connected electric lock. The is 2n helios ip security relay ® designed for any intercom model with firmware versions 1.15 and 2n helios ip ® higher....

  • Page 43: Wiegand Isolator

    43 2n telekomunikace a.S., www.2n.Cz ® the device also supports a departure button connected between the ‘pb’ and ‘- heliosip’ terminals. Press the departure button to activate the output for 5 seconds. Status signalling: green led red led status blinking off operational mode on off activated output...

  • Page 44

    44 2n telekomunikace a.S., www.2n.Cz ® the is designed for galvanic isolation of two 2n helios ip wiegand isolator ® devices with separate power supply and interconnected via the wiegand bus. The 2n ® protects the interconnected devices against helios ip wiegand isolator communication errors and/or ...

  • Page 45

    45 2n telekomunikace a.S., www.2n.Cz ® connection:.

  • Page 46

    46 2n telekomunikace a.S., www.2n.Cz ®.

  • Page 47: 2.5 Button Tags

    47 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 2.5 button tags this subsection describes work with button tags in . 2n ® helios ip force tag printing every delivery includes a sheet of translucent foil, which 2n ® helios ip force can be laser-printed. Cut the printed foil and insert the tags in the na...

  • Page 48: 3. Function and Use

    48 2n telekomunikace a.S., www.2n.Cz ® 3. Function and use in this section we describe the basic and extending functions of the 2n ® helios ip product. Force here is what you can find in this section: 3.1 configuration 3.2 control 3.3 maintenance.

  • Page 49: 3.1 Configuration

    49 2n telekomunikace a.S., www.2n.Cz ® 3.1 configuration use a pc equipped with any web browser to configure : 2n ® helios ip force launch your web browser (internet explorer, firefox, etc.). Enter the ip address of your intercom (http://192.168.1.100/, e.G.). Log in using the user name and password...

  • Page 50

    50 2n telekomunikace a.S., www.2n.Cz ® static ip address setting for 4-button models follow the instructions below to enable the static ip address mode: connect to the power supply (or, disconnect and 2n ® helios ip force reconnect it if already connected). Wait for the first acoustic signal . Press...

  • Page 51

    51 2n telekomunikace a.S., www.2n.Cz ® the acoustic signal indicates mode switching. Wait until the device is restarted automatically. 2n ® helios ip force gets the ip address upon restart only if the dhcp server is configured properly. Mode switching with 1 or 2-button models in case your device is...

  • Page 52

    52 2n telekomunikace a.S., www.2n.Cz ® the static ip address mode will be switched into the dynamic ip address mode and vice versa upon restart. Caution the 15 times 1 sequence must be entered within 30 seconds after the first sound signal for security reasons. The inter-digit delay may be 2 s at mo...

  • Page 53: 3.2 Control

    53 2n telekomunikace a.S., www.2n.Cz ® 1. 2. 3. 4. 3.2 control this subsection describes how to control when viewed by an 2n ® helios ip force external user. Speed dial buttons press the speed dial buttons on the basic unit to make quick dialling for the first 1, 2 or 4 positions (depending on the m...

  • Page 54

    54 2n telekomunikace a.S., www.2n.Cz ® answering and rejecting incoming calls if the automatic incoming call answering function is off, signals 2n ® helios ip force an incoming call with loud ringing. Push the button to answer the call and the to reject the call. This function is available in models...

  • Page 55: 3.3 Maintenance

    55 2n telekomunikace a.S., www.2n.Cz ® 3.3 maintenance cleaning if used frequently, gets dirty. To clean it, use a piece of soft 2n ® helios ip force cloth moistened with clean water. We recommend you to obey the following principles while cleaning: never use aggressive detergents (such as abrasives...

  • Page 56: 4. Technical Parameters

    56 2n telekomunikace a.S., www.2n.Cz ® 4. Technical parameters signalling protocol sip (udp, tcp, tls) buttons button design: transparent, white backlit buttons with easily replaceable name tags count of buttons: 1, 2 or 4 numerical keypad: optional audio microphone: 2 integrated microphones amplifi...

  • Page 57: Video Stream

    57 2n telekomunikace a.S., www.2n.Cz ® video stream protocols: rtp/rtsp/http codecs: h.263+, h.263, h.264, mpeg-4, m-jpeg ip camera function: yes interface power supply: 12 v ±15 % / 2 a dc or poe poe: poe 802.3af (class 0 - 12.95 w) lan: 10/100base-tx s auto-mdix, rj-45 recommended cabling: cat-5e ...

  • Page 58: Rfid Card Reader

    58 2n telekomunikace a.S., www.2n.Cz ® rfid card reader optional includes besides card reader itself: wiegand interface, tamper switch, active output, relay, two inputs supported cards on 125 khz version, 9151011 em-40xx (125 khz) hid proximity (125 khz, 26-bit) supported cards on 13.56 mhz version,...

  • Page 59: 5. Supplementary Information

    59 2n telekomunikace a.S., www.2n.Cz ® 5. Supplementary information here is what you can find in this section: 5.1 troubleshooting 5.2 directives, laws and regulations 5.3 general instructions and cautions.

  • Page 60: 5.1 Troubleshooting

    60 2n telekomunikace a.S., www.2n.Cz ® 5.1 troubleshooting for the most frequently asked questions refer to . Faq.2n.Cz.

  • Page 61: Europe

    61 2n telekomunikace a.S., www.2n.Cz ® 5.2 directives, laws and regulations europe 2n ® helios ip force conforms to the following directives and regulations: directive 1999/5/ec of the european parliament and of the council, of 9 march 1999 – on radio equipment and telecommunications terminal equipm...

  • Page 62: Fcc

    62 2n telekomunikace a.S., www.2n.Cz ® fcc note: this equipment has been tested and found to comply with the limits for a class b digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference in a residential installatio...

  • Page 63

    63 2n telekomunikace a.S., www.2n.Cz ® 5.3 general instructions and cautions please read this user manual carefully before using the product. Follow all instructions and recommendations included herein. Any use of the product that is in contradiction with the instructions provided herein may result ...

  • Page 64

    64 2n telekomunikace a.S., www.2n.Cz ® electric waste and used battery pack handling do not place used electric devices and battery packs into municipal waste containers. An undue disposal thereof might impair the environment! Deliver your expired electric appliances and battery packs removed from t...

  • Page 65

    65 2n telekomunikace a.S., www.2n.Cz ® 2n telekomunikace a.S. Modřanská 621, 143 01 prague 4, czech republic phone: +420 261 301 500, fax: +420 261 301 599 e-mail: sales@2n.Cz web: www.2n.Cz en2065_v2.0.3.