3i Dualnet-6 Instruction Manual

Manual is about: Combined Hardwired and Wireless Control Alarm Panel with Incorporated Telephone diallers GSM, PSTN & Digital

Summary of Dualnet-6

  • Page 1

    Pag. 1 dualnet—6 instruction manual english instruction manual tre i systems s.R.L. Via del melograno n. 13 - 00040 ariccia, roma italy tel:+39 06 97249118 fax: +39 06 45557618 e-mail m.Tomasino@treisystems.Com website: www.Treisystems.Com dualnet-6 combined hardwired and wireless control alarm pane...

  • Page 2

    Pag. 2 dualnet-6 manual english summary page description ........................................................................................................................... 3 general characteristics ................................................................................................

  • Page 3

    Pag. 3 dualnet—6 instruction manual english description: tre i systems thanks you for having selected the new concept dual communication control panel for the protection of your home, business and belongings. The dualnet-6offers the end user the most modern data transmission technology present in to...

  • Page 4

    Pag. 4 dualnet-6 manual english control panel description: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 z7 gnd z8 z9 gnd z10 z11 gnd z12 z13 gnd z14 2 3 1 4 6 7 8 9 5 fig.1 ext. Pulse no +12v rx tx gnd mic2n mic2p beep aux z1 gnd z2 z3 gnd z4 z5 gnd z6 relay siren on ni...

  • Page 5

    Pag. 5 dualnet—6 instruction manual english pcb component description number description of functions (see fig. 1) 1 s1: connector for tamper button (see note “a” below) 2 led cpu: led which indicates the microprocessor status 3 sim card socket: to insert local sim card. 4 led 2: front panel power l...

  • Page 6

    Pag. 6 dualnet-6 manual english keypad description: terminal block connection to mother board backside view wall attachment slide keypad reset keys for programming and functions program up key & hold-up trigger program down key & fire trigger medical distress key confirmation key led indicators touc...

  • Page 7

    Pag. 7 dualnet—6 instruction manual english brief description of the panel status on keypad display: while panel is not armed press or to have the gsm status information; after 20 seconds the keypad will return to normal status. Note: in the case you see, on keypad, “no sim card” even if the sim car...

  • Page 8

    Pag. 8 dualnet-6 manual english brief description of keypad commands: (*) note: the control of the hardwire zones (from 1 to 14) is active only if the program is set in “zone ready” and “yes” is selected. (see page 22). In any case the zones that are triggered when the panel is armed, will be automa...

  • Page 9

    Pag. 9 dualnet—6 instruction manual english description of panel sounder: description of the alarm triggers: a burglary alarm trigger during “day” mode arming (see par.09 “zone settings” page 19 option “zone type 2”). The siren will be triggered only if the panel is armed in day mode (see page 27). ...

  • Page 10

    Pag. 10 dualnet-6 manual english 00 password management: how to change the end user password (factory setting is 1111) with control panel disarmed, on keypad press: on display will appear: to change the end user password, on the display select “user code”, and confirm with on the display will appear...

  • Page 11

    Pag. 11 dualnet—6 instruction manual english how to change the emergency password (see paragraph 21 page 29) with panel in disarmed status on the keypad press: on the display will appear: to change the emergency password = “distress code”, confirm with on the display will appear: digit the installer...

  • Page 12

    Pag. 12 dualnet-6 manual english how to navigate in the dualnet-6 progamming menu the following keypad buttons are used to navigate with-in the program. 01. To enter into progamming mode be sure that the control panel is disarmed before you digit on the keypad enter the factory installed password (1...

  • Page 13

    Pag. 13 dualnet—6 instruction manual english 02. To insert the automatic dialler telephone numbers after having interring the programming mode, nr. ( telephone number) will flash. Press the key to enter into the menu of telephone number programming. On the display will appear: with the keys or selec...

  • Page 14

    Pag. 14 dualnet-6 manual english 03. To record the voice message enter the programming menu and go to the window “rec. Message” press the key the display will show: with the keys or select “ yes” and confirm with ; on the display will appear: record a 10 sec. Message by speaking clearly into the mic...

  • Page 15

    Pag. 15 dualnet—6 instruction manual english 04. How to set the entrance delay time enter the programming menu and go to the window “entry delay” press the key on the display will appear: inter the entry time desired form 00 to 59 seconds. Use always 2 figures. At the end press the key to return to ...

  • Page 16

    Pag. 16 dualnet-6 manual english 06. Setting the siren trigger time enter the main menu and go to the “siren duration” press key on the display will appear: set the “emergency” siren duration time; you may set from 00 to 59 minutes. This time must be memorize always using 2 digits as seen above 00 a...

  • Page 17

    Pag. 17 dualnet—6 instruction manual english 5 t 07. Management of central monitoring station (cms) enter the programming menu and go to the window “cms options” press the key on the display appears: inter your account number from 0000 to 9999. This number must be supplied by the cms. If this number...

  • Page 18

    Pag. 18 dualnet-6 manual english in order that this function be active you must set the display so that it will show 00010 to 99999 minutes, if the display shows this test is not in function. (from 00001 to 00009 is not accepted.) at the end press the key to return to the preceding menu or the key t...

  • Page 19

    Pag. 19 dualnet—6 instruction manual english 09. Attributing the zones enter the programming menu and go to the window “zone attribute” press the key on the display will appear: to select the zone number to which you wish to attribute the sensor, you must press the key and digit the number of the zo...

  • Page 20

    Pag. 20 dualnet-6 manual english indication of how to define a zone (*) example: if the hardwire zone expansion module (dn-8z) is not used you must by-pass the zone 07 to 14. (**) see page 19 under 09 attribute the zones. Table no. 1 sensor codes sensor code test shown on keypad & sms cid displays c...

  • Page 21

    Pag. 21 dualnet—6 instruction manual english hardwired zone 01 02 03 04 05 06 zone type bypass delay sensor code 01 01 01 01 01 01 zone type 0 no no hardwired zone 07 08 09 10 11 12 13 14 zone type bypass delay sensor code 01 01 01 01 01 01 01 01 zone type 0 no no table 2 : factory settings for the ...

  • Page 22

    Pag. 22 dualnet-6 manual english on the display will appear: if you select “yes” and i proceed to arm the panel after i have exited the programming mode and this zone is triggered the control panel will indicate on the display that the zone is “not ready” “check” and immediately there after you will...

  • Page 23

    Pag. 23 dualnet—6 instruction manual english note: if the end user wishes to know which sensor has triggered the alarm, low battery or tamper, it is best to memorize only 1 sensor in each zone. Group 0-1-2-3 = this means that each zone may memorize up to 4 sensor codes and the number 0 to 3 will ind...

  • Page 24

    Pag. 24 dualnet-6 manual english . 13 . Alarm reports enter in the main menu and go to “alarm history” press the key on the display you will see: by pressing the key the display will show number date and hour of the event. With the keys or the end user or installer may go up and down in the event lo...

  • Page 25

    Pag. 25 dualnet—6 instruction manual english 15 . Hour setting enter the main menu and go to the window “hour setting” press the key on the display you will see: to change the hour ii is necessary to press and insert the new time.. Then press to confirm. At the end press the key to return to the mai...

  • Page 26

    Pag. 26 dualnet-6 manual english 1 to arm in day mode 2 to arm in night mode 3 for total disarm 4 for listen-in function 17. Management of panel from remote: to activate the option of remote settings of the dualnet-6 with sms commands from a cellular telephone, you must, in the main menu, go to the ...

  • Page 27

    Pag. 27 dualnet—6 instruction manual english 18. Panel functions: with the control panel disarmed, it is possible to arm by pressing the correct number on the keypad or wireless with a coded peg-3 transmitter that has been learned by the control panel to arm the panel in day mode with keypad: the in...

  • Page 28

    Pag. 28 dualnet-6 manual english 19. Alarm trigger sequence: in the case of an alarm trigger the control panel will go throw the following sequence: 1. The installed sensors will sense an intrusion and trigger the panel and all sirens connected. 2. The control panel will send an alarm trigger messag...

  • Page 29

    Pag. 29 dualnet—6 instruction manual english 21. Hold-up alarm trigger procedure (distress code): in case of (hold-up or medical distress) it is possible to disarm the control panel with an emergency code : after having entered this emergency password, all sirens both hardwired and wireless will be ...

  • Page 30

    Pag. 30 dualnet-6 manual english technical characteristics: • power supply: maximum regulated 14 vdc. • current drain in disarmed status: • current drain in alarm trigger status: • approved transceiver module gw transk 1120 ® : 433.92 mhz. • c e approved gsm four band module zte mg2639. • pstn telep...

  • Page 31

    Pag. 31 dualnet—6 instruction manual english zone description burglary fire and gas configuration of zone 1 immediate delay day night 2 immediate delay day night 3 immediate delay day night 4 immediate delay day night 5 immediate delay day night 6 immediate delay day night 7 immediate delay day nigh...

  • Page 32

    Pag. 32 dualnet-6 manual english latest revision: 03-10-2014 made in italy tre i systems s.R.L. ® via del melograno 13 - 00040 ariccia, rome - italy tel: +39 06 97249118 fax: +39 06 45557618 e-mail m.Tomasino@treisystems.Com w ebsite: http://www.Treisystems.Com : tre i systems ® installed by: teleph...