3M 718 User Manual

Other manuals for 718: Instruction Manual
Manual is about: Static Sensor/ Air Ionizer Test Kit

Summary of 718

  • Page 1

    User’s guide 3m ™ static sensor 718, 3m ™ air ionizer test kit 718a.

  • Page 2

    1 table of contents section page safety information..................................................................................... 2 1 description ................................................................................................ 3 2 power requirements and battery installation .....

  • Page 3

    2 safety information intended use: the 3m ™ static sensor 718 is a portable, handheld instrument designed for measuring voltages associated with electrostatic charge. Its intended use is for measuring the amount of voltage, in a range from 19,900 kilovolts, associated with an electrostatic charge bu...

  • Page 4

    3 1.0 description the 3m ™ static sensor 718 is a portable handheld instrument used for locating and measuring electrostatic charges. It can beused to locate esd trouble-areas, and is a valuable tool for the esd-control engineer. Used in conjunction with the 3m ™ air ionizer test kit 718a (available...

  • Page 5: Supplemental Notes:

    4 2.3 the 3m ™ static sensor 718 has a low battery indicator. Once the battery is depleted to approximately 6.5 volts, the instrument will show bat in the display. At this time, the static sensor 718 will not produce accurate results and the battery should be replaced. 2.4 the 3m ™ charger 718a also...

  • Page 6

    5 the 3m ™ static sensor 718 is a precision electronic instrument. Improper use or rough treatment can damage the unit, and render it incapable of providing accurate measurements.2.2.4 replace the cover. 2.3 the static sensor 718 has a low battery indicator. Once the battery is depleted to approxima...

  • Page 7: Zero Adjustment: The 3M

    6 and return to floating measurement, momentarily press the hold switch once again. Please note that during hold condition the distance indicating led’s are turned off. 3.5 zero adjustment: the 3m ™ static sensor 718 has a zero adjustment function, which sets a zero reference point for all subsequen...

  • Page 8

    7 3.7 continuous output: an output jack is provided on the front of the 3m ™ static sensor 718. This output can be used to feed a continuous signal into a data storage device for continuous monitoring of measured voltages. Please use a 3/32 inch (2.5 mm) mono-phone plug to connect into the output ja...

  • Page 9

    8 indicate a positive or negative charging voltage (1.1kv minimum). If a voltage of less than ±1.1kv is displayed, check to see if the low battery indicator on the 3m ™ charger 718a is illuminated. If illuminated, replace the battery in the charger. If the unit continues to supply an incorrect volta...

  • Page 10: Calibration: The 3M

    9 5.2 calibration: the 3m ™ static sensor 718 and 3m ™ air ionizer test kit 718a products are supplied by the factory pre-calibrated. 3m does not specify a minimum calibration cycle for the static sensor 718 or air ionizer test kit 718a products. The user, usually according to internal quality proce...

  • Page 11

    10 6.0 physical characteristics (all values typical) (at 1 inch (2.54 cm) distance from sensor to target) 3m ™ static sensor 718 description typical value dimensions 0.85" h x 2.4" w x 4.2" l 2.2 cm h x 6.1 cm w x 10.6 cm l weight 4.4 oz. (125 g) with battery operating conditions 41º f - 95º f (5º c...

  • Page 12: Static Sensor 718

    11 7.0 parts included static sensor 718 1 ea. Static sensor 718 1 ea. 718/718a user’s guide air ionizer test kit 718a 1 ea. Charge plate assembly 718a 1 ea. Charger 718a 1 ea. 718/718a user’s guide 3m ™ air ionizer test kit 718a description typical value charge plate assembly per esd association dra...

  • Page 13: Weee Statement

    12 regulatory information weee statement the following information is only for eu-members states: the mark shown to the right is in compliance with waste electrical and electronic equipment directive 2002/96/ec (weee). The mark indicates the requirement not to dispose the equipment as unsorted munic...

  • Page 14

    Important notice all statements, technical information, and recommendations related to 3m’s products are based on information believed to be reliable, but the accuracy or completeness is not guaranteed. Before using this product, you must evaluate it and determine if it is suitable for your intended...