ABB SafeRing Installation And Operating Instructions Manual

Manual is about: SF6 insulated ring main unit and compact switchgear

Summary of SafeRing

  • Page 1

    Nopowsr 5976 gb 1 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions nopowsr 5976 gb safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions nopowsr 5976 gb.

  • Page 2: Safering / Safeplus

    Nopowsr 5976 gb 2 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions contents 1. General description ........................................................ 3 1.1 table of locations ................................................

  • Page 3: Safering / Safeplus

    Nopowsr 5976 gb 3 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions safering / safeplus with vacuum circuit-breaker in compliance with iec 60056 with this unit the transformer will be protected by a vacuum circuit breaker combi...

  • Page 4: Safering / Safeplus

    Nopowsr 5976 gb 4 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 1. Lifting lugs 2. Capacitive voltage indication (additional equipment) 3. Short circuit indicator (additional equipment) 4. Pressure indicator (additional equ...

  • Page 5: Safering / Safeplus

    Nopowsr 5976 gb 5 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions nhp 102103 1-way 3 7 1 2-way 6 9 6 3-way 1021 4-way 1346 5-way 1671 unit m m 1.2 dimensional drawings.

  • Page 6: Safering / Safeplus

    Nopowsr 5976 gb 6 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 2. Transport and handling the units are delivered from the factory ready for installation. Weight table for standard safering 2-way dv 252 kg 2-way df 260 kg 3...

  • Page 7: Safering / Safeplus

    Nopowsr 5976 gb 7 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 3.1 electrical data 3. Technical data c-module f-module v-module safering switch downstream vacuum circuit disconnector earthing switch switch fuse earthing sw...

  • Page 8: Safering / Safeplus

    Nopowsr 5976 gb 8 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions ny tabell kommer transformer rating (kva): cef 7,2 kv 12 kv 17,5 kv 24 kv un (kv) 25 50 75 100 125 160 200 250 315 400 500 630 800 1000 1250 1600 3 16 25 25 40...

  • Page 9: Safering / Safeplus

    Nopowsr 5976 gb 9 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 4. Installation the base must be flat and fitted with anchor bolts in accordance with the dimensional drawing for the number of modules or units as appropriate...

  • Page 10: Safering / Safeplus

    Nopowsr 5976 gb 10 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 4.1 cable compartment removal of cable cover: nb! The cable cover can be supplied with interlocking to earthing switches. When interlocking is fitted, the cab...

  • Page 11: Safering / Safeplus

    Nopowsr 5976 gb 11 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 4.2 cable connection safering/ safeplus is equipped with external bushings which comply with din47636t1 & t2/edf hn 525-61 for termination of cables. All bush...

  • Page 12: Safering / Safeplus

    Nopowsr 5976 gb 12 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions the cable shielding is led back through the centre hole and earthed. 4.3 current transformers for relay protection installing current transformers. The cable ...

  • Page 13: Safering / Safeplus

    Nopowsr 5976 gb 13 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 4.4 gas pressure safering / safeplus contains sf 6 gas with a nominal pressure of 1.4 bar at 20 o c. Safering/ safeplus is «sealed for life» and is fitted wit...

  • Page 14: Safering / Safeplus

    Nopowsr 5976 gb 14 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 5.2 operation all switches can be operated with the included operating handle. Internal mechanical interlocking between the switch disconnector/isolator and t...

  • Page 15: Safering / Safeplus

    Nopowsr 5976 gb 15 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 5.3 installation and replacement of fuses a red indicator below the fuse symbol on the lower front panel indicates a fuse trip. Fuses are replaced as shown in...

  • Page 16: Safering / Safeplus

    Nopowsr 5976 gb 16 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 7. Fix the fuses to the fuse cover using the contact screw - the striker must point out from the fuse canister for the fuse to function properly. Fuse striker...

  • Page 17: Safering / Safeplus

    Nopowsr 5976 gb 17 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 6.1 low-voltage connections auxiliary contacts (2no+2nc) can be supplied to indicate switch positions on all switches/breakers. Access to the low-voltage conn...

  • Page 18: Safering / Safeplus

    Nopowsr 5976 gb 18 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 6.3 capacitive voltage indication socket for capacitive voltage ondication hr-module iec 61243-5 phase balance check capacitive voltage indicator type catu vo...

  • Page 19: Safering / Safeplus

    Nopowsr 5976 gb 19 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 6.6 cable testing voltage testing and locating cable faults can be performed in two ways: 6.5 motor operation cable switches, vacuum circuit-breakers and eart...

  • Page 20: Safering / Safeplus

    Nopowsr 5976 gb 20 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 6.7 external busbar safering and safeplus can be equiped with an external busbar. See seperate instruction manual nopowsp 6006 gb. 6.8 arc-suppressor an arc-s...

  • Page 21: Safering / Safeplus

    Nopowsr 5976 gb 21 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 7. Maintenance all components in the sf 6 tank are maintenance-free for the declared life expectancy of the product. The tank is made of stainless steel. If t...

  • Page 22: Safering / Safeplus

    Nopowsr 5976 gb 22 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions 7.2 environmental certification 1. Life expectancy of product the product is developed in compliance with the requirements denoted by iec 298. The design inco...

  • Page 23: Safering / Safeplus

    Nopowsr 5976 gb 23 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions.

  • Page 24: Safering / Safeplus

    Nopowsr 5976 gb 24 abb / ptmv safering / safeplus sf6 insulated ring main unit and compact switchgear installation and operating instructions nopowsr 5976 gb edition 4 - june 2001 - 6000 oluf rasmussen as, skien abb as power technology medium voltage p. O. Box 108, sentrum n-3701 skien norway tel: +...