Abrelex EnerSolis ES 10000 User Manual

Manual is about: EnerSolis Series Grid Tie Solar Inverter Three-Phase , 6 / 8 / 10 /12 kW

Summary of EnerSolis ES 10000

  • Page 1

    Version 1.1 grid tie solar inverter enersolis series es 6000 es 8000 es 10000 es 12000 three-phase , 6 / 8 / 10 /12 kw user’s manual 1 contents 1 foreword ........................................................................................................... 2 2 important safety instructions ......

  • Page 2

    2 1 foreword thank you for purchasing the enersolis es 6000(es 8000/es 10000/es 12000) grid tie solar inverter. Many years of experience in the design of power devices have gone into the construction of this device. We hope that it will give your solar power system many years of trouble-free operati...

  • Page 3

    4 ■ warning below warning symbols are described according to related sections: symbol description caution, risk of electric shock ! Caution, risk of danger ! Caution , hot surface ! The pv inverter surface temperature of the casing can exceed +70 °c . Caution, risk of electric shock energy storage t...

  • Page 4

    6 3 overview 3.1 3.1 3.1 3.1 external dimensions model number dimensions (mm) es 6000 es 8000 es 10000 es 12000 w 451 451 451 451 h 595 595 595 595 d 247 247 247 247 7 3.2 3.2 3.2 3.2 external features 1. Lcd and led display: shows operation information and status. 2. Solar array input: plug-and-pla...

  • Page 5

    8 4 installation warning: be sure to read the safety instructions on pages 3 and 4 before installing the pv inverter. 4.1 4.1 4.1 4.1 unpacking inspect the pv inverter upon receipt. The packaging is robust, but accidents and damage may still occur during shipment. Notify the forwarder and dealer if ...

  • Page 6

    10 (2) the pv inverter is designed to be mounted on a vertical wall. If installing the unit outdoors make sure that it is not slanting forward. We advise against installing the unit in a horizontal position outdoors. (3) when choosing the installation site ensure that there is enough space for heat ...

  • Page 7

    12 4.3.1 4.3.1 4.3.1 4.3.1 using the mounting bracket method i: use the backplane to fix the unit step 1. Put the backplane position paper on the intended spot of the wall. Drill holes based on the diameter of the backplane to fix holes. Finally , fix the backplane on the wall. Step 2. Screw the nut...

  • Page 8

    14 4.4 4.4 4.4 4.4 electrical installation caution ! Risk of electric shock ! ■ make sure the ac breaker or switch installed between the pv inverter and the grid (ac utility). Note : please use ue: 690vac / ie:25a circuit breaker. ■ make sure the dc breaker or switch installed between the pv inverte...

  • Page 9

    16 step 4. Insert the utility cable through the cable gland. Connect the wires to the terminal block as shown in figure 3. Figure 3 step 5. Reattach the cover, and evenly tighten the four screws. Warning: to prevent risk off electric shock ensure that the ground (pe) wire is properly earthed before ...

  • Page 10

    18 4.4.3 4.4.3 4.4.3 4.4.3 connecting the pv array (dc) 4.4.3.1 4.4.3.1 4.4.3.1 4.4.3.1 pv array requirements the es 6000(es 8000/es 10000/es 12000) pv inverter is designed to be connected to an array of up to two pv strings. The two pv strings can contain different numbers of pv modules. 4.4.3.2 4....

  • Page 11

    20 4.4.3.3 4.4.3.3 4.4.3.3 4.4.3.3 requirements for connection figure 7. Dc connections for a two-string pv array the number of solar panels in string a need not equal the number in string b. For a single pv string enter settings mode and configure for parallel operation. 21 5 front display panel sy...

  • Page 12

    22 led indicators ○ 2 red led shines steadily to indicate a ground fault or dc input isolation fault. ○ 3 yellow led shines steadily to indicate that the utility does not match the input standard of the inverter (voltage, frequency, etc.). ○ 4 green led shines steadily when the solar power is greate...

  • Page 13

    24 d c e 6.1.3 6.1.3 6.1.3 6.1.3 turn on the ac breaker. If the utility specification (voltage, frequency, etc.) matches the inverter, after thirty seconds the lcd will display drawing c, and the yellow led will stop shining, indicating that the utility is acceptable to the inverter. If the utility ...

  • Page 14

    26 6.2.3 6.2.3 6.2.3 6.2.3 input dc current of string a 6.2.4 6.2.4 6.2.4 6.2.4 input dc current of string b 6.2.5 6.2.5 6.2.5 6.2.5 output power of booster a 6.2.6 6.2.6 6.2.6 6.2.6 output power of booster b 6.2.7 6.2.7 6.2.7 6.2.7 output voltage a of the inverter (utility voltage) i j k l m 27 6.2...

  • Page 15

    28 6.2.13 6.2.13 6.2.13 6.2.13 output current c supplied to the load 6.2.14 6.2.14 6.2.14 6.2.14 output power supplied to the load 6.2.15 6.2.15 6.2.15 6.2.15 energy in kwh supplied to the load 6.2.16 6.2.16 6.2.16 6.2.16 inverter inner temperature (in either °f or °c) (°f or °c display change from ...

  • Page 16

    30 7 communication interfaces 7.1 7.1 7.1 7.1 standard communication interfaces 7.1.1 7.1.1 7.1.1 7.1.1 rs-232 interface definition the rs-232 interface must be configured as follows: baud rate 9600 bps data length 8 bits stop bit 1 parity none rs-232 pin assignments are as follows (the connector is...

  • Page 17

    32 7.2 7.2 7.2 7.2 optional communication card 7.2.1 7.2.1 7.2.1 7.2.1 hardware installation procedure caution ! Risk of electric shock ! ■ when working on the solar power system, disconnect the ac breaker or switch. ■ turn the dc input switch to off position, referring to section 4.4.2. Figure 5 ■ ...

  • Page 18

    34 7.2.3 7.2.3 7.2.3 7.2.3 usb card 7.2.3.1 7.2.3.1 7.2.3.1 7.2.3.1 jack cn2 is for usb. 7.2.3.2 7.2.3.2 7.2.3.2 7.2.3.2 definition: 7.2.3.3 7.2.3.3 7.2.3.3 7.2.3.3 complies with usb version 1.0 and 1.5 mbps. 7.2.3.4 7.2.3.4 7.2.3.4 7.2.3.4 complies with usb hid version 1.0. 7.2.3.5 7.2.3.5 7.2.3.5 ...

  • Page 19

    36 7.2.5 7.2.5 7.2.5 7.2.5 tcp/ip cards 7.2.5.1 7.2.5.1 7.2.5.1 7.2.5.1 tcp/ip (ethernet) card 7.2.5.2 7.2.5.2 7.2.5.2 7.2.5.2 for installation please refer to the user’s manual included with the card. 7.2.6 7.2.6 7.2.6 7.2.6 wifi cards 7.2.6.1 7.2.6.1 7.2.6.1 7.2.6.1 for installation please refer t...

  • Page 20

    38 9 inverter status diagnostics and repair the pv inverter is equipped with a self diagnostic system that automatically identifies many possible operational issues and displays information about them on the lcd. Therefore it is possible to quickly isolate technical problems and to distinguish betwe...

  • Page 21

    40 table 3. Grid fault alarm codes and descriptions lcd designation description repair al00 utility over-voltage the utility voltage is greater than or less than the permissible values. 1. Wait for 1 minute. If the grid returns to normal then the inverter automatically restarts. 2. Check the grid co...

  • Page 22

    42 dc connector connector communication communication interfaces standard rs-232 & rs-485 optional usb, rs-485, dry contact, tcp / ip, wifi front panel lcd boost input voltage / boost input current / boost input power / ac output voltage / ac output frequency / ac output current / ac output power / ...