Accentronix CELLSWITCH 100 User Manual

Summary of CELLSWITCH 100

  • Page 1

    User manual for cellswitch 100 page 1 of 23 c ellswitch 100 control anything with your cellphone use your cellphone to remotely monitor and control the following applications with the cellswitch 100 security: electric fence / power-failure / fire sensors / alarm sensors access control: open your gat...

  • Page 2

    User manual for cellswitch 100 page 2 of 23 how does it work? The cellswitch is a kind of cellphone you connect to an electronic appliance or device to enable you to communicate with it using your own cellphone. You insert a pre-paid or contract sim card into the cellswitch and communicate with by s...

  • Page 3

    User manual for cellswitch 100 page 3 of 23 important: please read this information before installing the equipment. Intended users this manual is to be available to all persons who are required to install or configure equipment described herein, or any other associated operation. The information gi...

  • Page 4: Table of Contents

    User manual for cellswitch 100 page 4 of 23 table of contents how does is work? 2 caution 3 key features 5 system requirements 6 connection diagram 6 installation 7 power supply 7 sim card 8 antenna 8 physical dimensions 8 digital input 9 relay output 10 sms configuration / setup / programming 11 ge...

  • Page 5

    User manual for cellswitch 100 page 5 of 23 key features 2 x digital inputs to monitor alarms, sensors, etc. 1 x relay output to switch lights on/off, open gate/garage, etc. Controllable via voice-call simply call the device with your cellphone to control the output. Confirmation sms the device will...

  • Page 6

    User manual for cellswitch 100 page 6 of 23 system requirements programming: the cellswitch is programmed by sending it sms messages from your cellphone containing specific commands. Whenever a valid command is received by the device, a confirmation sms will be sent back to you stating that the devi...

  • Page 7

    User manual for cellswitch 100 page 7 of 23 installation power supply: wiring techniques wiring for the device has been designed to be safe and easy. If the user is concerned about the correct installation of these products or associated products, please contact a professional electrician who is tra...

  • Page 8

    User manual for cellswitch 100 page 8 of 23 sim card: use any vodacom or mtn pre-paid or contract sim. Disable the sim card’s pin number before installing it into the cellswitch. It is recommended to use a contract sim to avoid manual airtime top-up since most top- up packages expire after three mon...

  • Page 9

    User manual for cellswitch 100 page 9 of 23 digital inputs: when the input is triggered either high or low it will send a sms to the programmed reporting numbers. Terminal “in” is internally pulled low. Leaving the connection open or connecting it to “0v” will indicate an “input-low” state. When con...

  • Page 10

    User manual for cellswitch 100 page 10 of 23 relay output: the output is used to switch circuits on and off and is controlled by sending a sms from your cellphone to the cellswitch 100. The output can also be control by calling the cellswitch from your cellphone. When the device receives your call i...

  • Page 11

    User manual for cellswitch 100 page 11 of 23 sms configuration / setup / programming programming the device via sms please follow the step-by-step instructions below: the device is programmed by sending it sms messages from your cellphone containing specific commands. Whenever a command is received ...

  • Page 12: General Setup

    User manual for cellswitch 100 page 12 of 23 step 1 – program the device’s own name, cellphone number and behaviour when it is called. General setup device name (default: cellswitch 100) 1234.F1"cellswitch 100" the device's name displayed in the sms reports. Device’s own cellphone number 1234.F2"082...

  • Page 13: Security

    User manual for cellswitch 100 page 13 of 23 step 2 – program the desired security settings. Security add security numbers 1234.F4a”0827727789;0825091827;” when the unit is used for access or remote control. Only these cellphone numbers will be accepted by the unit when it is called. Note the semico...

  • Page 14: Sms Reporting Options

    User manual for cellswitch 100 page 14 of 23 step 3 – program the cellphone numbers the device must sms when an input is triggered. Sms reporting options 1234.F6a”0827727789” sms reporting number 1 programs the first number to sms and/or dial when an input is triggered. Sms reporting number 2 1234.F...

  • Page 15

    User manual for cellswitch 100 page 15 of 23 sms reporting options --- continued send power-up sms report 1234.F8on when the power to the device was interrupted it will send a notification sms when power is re-applied. Do not send power-up sms report (default) 1234.F8off when the power to the device...

  • Page 16: Digital Input Options

    User manual for cellswitch 100 page 16 of 23 step 4 – program the sms messaged that will be sent when the inputs are triggered. Digital input options input 1 high sms 1234.F9a”sensor 1 triggered” the sms that will be sent when input 1 is high (5 to 24 volt). Input 1 low sms 1234.F9b”water level low ...

  • Page 17

    User manual for cellswitch 100 page 17 of 23 digital input options --- continued call the reporting numbers 1234.F12on the device will first sms, then call the reporting numbers when an input is triggered. Do not call the reporting numbers (default) 1234.F12off the device will only sms and not call ...

  • Page 18: Output Relay Options

    User manual for cellswitch 100 page 18 of 23 step 5 – program how the output relay must behave when the device is called or sent a sms. Output relay options 1234.On switch the relay output on 1234.Off switch the relay output off output pulse mode (default) 1234.F15a when a voice call is received the...

  • Page 19

    User manual for cellswitch 100 page 19 of 23 output relay options --- continued output relay switching on confirmation sms 1234.F16a"lights switched on" when the unit is called and the output relay is switched on, this confirmation sms will be sent back. Output relay switching off confirmation sms 1...

  • Page 20: Sms I/o Control Commands

    User manual for cellswitch 100 page 20 of 23 step 7 – test the device by checking gsm signal strength, inputs and outputs. Sms i/o control commands 1234.Status request input/output and signal quality status. 1234.Signal requests the gsm signal strength 1,0 = bad signal. 30,0 = full signal 1234.Airti...

  • Page 21

    User manual for cellswitch 100 page 21 of 23 general specifications: operating temperature -10ºc to +50ºc storage temperature -40ºc to +70ºc operating humidity 35 to 85% relative humidity, no condensation storage humidity 35 to 90% relative humidity, no condensation vibration resistance - direct mou...

  • Page 22: □

    User manual for cellswitch 100 page 22 of 23 diagnostics preliminary checks before power up □ check 230vac power supply wiring □ check ground wiring □ check digital input wiring □ check relay output wiring □ check sim card power the device up check that power led turns on for about 10 seconds, then ...