Aire-Flo 4AC13 Series Installation/start-up Instructions/homeowners Information Manual

Manual is about: SPLIT SYSTEM AIR CONDITIONER

Summary of 4AC13 Series

  • Page 1

    506320-01 issue 1012 page 1 of 10 these instructions must be read and understood completely before attempting installation. Issue 1012 safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 unit location & installation . . . . . . . . . . . . . . . . . . . ....

  • Page 2: Safety Precautions

    506320-01 issue 1012 page 2 of 10 safety precautions follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warning or cautions attached to the unit. 1. Always wear ...

  • Page 3

    506320-01 issue 1012 page 3 of 10 elevate unit elevate unit per local climate and code requirements to provide clearance above estimated snowfall level and ensure adequate drainage of unit. Use snow stand in areas where prolonged freezing temperatures are encountered. If conditions or local codes re...

  • Page 4

    506320-01 issue 1012 page 4 of 10 installation of line sets do not fasten liquid or suction lines in direct contact with the floor or ceiling joist. Use an insulated or suspension type of hanger. Keep both lines separate, and always insulate the suction line. Long liquid line runs (30 feet or more) ...

  • Page 5

    506320-01 issue 1012 page 5 of 10 electrical connections be sure to check all local codes to determine that the unit is installed in accordance with local requirements. Consult the national electric code for wire size requirements. Use 60 / c or higher copper wires only. Always provide ground connec...

  • Page 6

    506320-01 issue 1012 page 6 of 10 cooling cycle charge adjustment procedure units with indoor pistons units installed with indoor pistons require charging with the superheat method. The following procedure is valid when indoor airflow is within ± 20% of its rated cfm. 1. Operate unit a minimum of 10...

  • Page 7

    506320-01 issue 1012 page 7 of 10 a/c single phase wiring diagram.

  • Page 8: Homeowner'S Information

    506320-01 issue 1012 page 8 of 10 homeowner's information important system information ! Your system should never be operated without a clean air filter properly installed. ! Return air and supply air registers should be free from restrictions or obstructions to allow full flow of air. Regular maint...

  • Page 9

    506320-01 issue 1012 page 9 of 10 notes.

  • Page 10

    506320-01 issue 1012 page 10 of 10 notes.