BaltGaz NEVA-4511 User Manual

Summary of NEVA-4511

  • Page 1

    Dear customer, thank you for purchasing our gas water heater. At purchasing the appliance please check: - the scope of delivery; - compatibility of pressure and the type of gas (natural or liquefied) used by you, with the pressure and type of gas indicated in the acceptance certificate and with the ...

  • Page 2

    Table of contents 1. Safety measures indication ................................................................................................................................ 3 2. Description and operation of the appliance ..............................................................................

  • Page 3

    1. Safety measures indication 1.1. In order to avoid accidents and the appliance ’s breakdown it is prohibited to: - install and put the appliance into operation by yourself; - to switch the appliance on and regulate it in case if the person is not acquainted with this manual; - to close the grid or...

  • Page 4

    2. Description and operation of the appliance 2.1. Purpose of the appliance 2.1.1. The instantaneous gas water heaters for domestic use «neva-4511», hereinafter referred to as “appliances”, are produced according to the tu 4858-008-26985921-2008 (gost r 51847-2009) standard and are designed for wate...

  • Page 5

    2.3. Supply package table 2. «batgaz neva-4511» supply package designation name quantity, pcs. 3272-00.000 water heater «baltgaz neva-4511» 1 3251-00.000-01 re user’s manual 1 3272-10.000 package 1 3208-06.600 mounting hardware set 1 spare parts 3103-00.014 laying d19xd10x2 2 note. The batteries are...

  • Page 6

    2.4. Overall and connection dimensions of the appliance «baltgaz neva-4511» 1 – water consumption regulation knob; 2 – gas consumption regulation knob; 3 – water temperature display; 4 – casing; 5 – glory-hole; 6 – cold water inlet tap, screw thread g 1/2; 7 – gas inlet tap, screw thread g 1/2; 8 – ...

  • Page 7

    The water heater on occurs at water consumption not less than 2,5 l/min, at the knob position at “maximum consump- tion ” – at water consumption not less than 6 l/min. In the in-between positions of the knob 1 switching the water heater on occurs, respectively, in the consumption range not less than...

  • Page 8

    3.5.1. At battery discharge it is necessary to install new batteries (2 pcs.) of dimension-type d into the battery sec- tion 14 (see scheme 14), in accordance with polarity, indicated on the internal side of the section ’s coverplate. He indica- tor of battery discharge is the absence or a sustainab...

  • Page 9

    4. Appliance treatment in order to provide long-term and failure-free operation of the appliance and keep its operating characteristics it is necessary to regularly effect its examination, treatment and technical service. In order to provide fire safety it is necessary to carefully control the burne...

  • Page 10

    5. Transportation and storage rules 5.1. The appliance must be stored and transported in the package only in the position indicated on the handling symbols. 5.2. The appliance must be stored in a closed premise that guarantees protection from atmosphere and other harmful impacts at air temperature f...

  • Page 11

    7.1.5. The appliance must be installed on fire resistant walls - brick- built, concrete (with ceramic plating or without it). 7.1.6.It is acceptable to install the appliance on slow burning walls in condition if the wall is isolated by a zinc-coated steel sheet 0,8…1 mm thick on a sheet of basalt fe...

  • Page 12

    Attention! Do not let little children play with the packaging material, as it may be dangerous for them. After installing the appliance the package may be utilized. 7.2.2. The appliance is hanged by mounting holes (on the rear wall) on two hangers installed into the wall (hangers and wall dowels are...

  • Page 13

    7.5.7. It is recommended to keep gas balloons in a special metal cabinet in order to limit access of children and unauthor- ized persons to them. 7.6. Hoses installation rules 7.6.1. Hoses used for the appliance ’s connection must be certified for conforming use. After their working lifespan ’s term...

  • Page 14

    7.7. Connecting the appliance to the smoke exhauster 7.7.1. In order to remove all gas combustion products and to provide safe operation of the appliance the following requirements to the smoke exhauster and gas fue pipe, connecting the appliance and the smoke exhauster, must be fulfilled:: the smok...

  • Page 15

    7.8. Battery installation into the appliance «baltgaz neva-4511» batteries of the dimension-type d (2 pcs. Of 1,5 v voltage) are installed into the battery section 14 (see scheme 14) in accordance with polarity, indicated on the internal side of the section ’s coverplate. In order to open the batter...

  • Page 16

    8.4. Operation of the appliance «baltgaz neva-4511» 8.4.1. The appliance ’s flow chart is represented on scheme 15. 8.4.2. At the beginning of water flow through the water block 22 with water consumption not less than 2,5 l/min the gas valve 30 is opened by the membrane stem 25 and the contacts of t...

  • Page 17

    1 – water consumption regulator; 2 – gas consumption regulator; 3 – tablet; 4 – water and gas block; 5 – burner; 6 – cold water inlet tap; 7 – gas inlet tap; 8 – hot water ourlet tap; 9 – gas removal device; 10 – ignition plug; 11 – flame sensor; 12 – heat exchanger; 13 – electromagnetic valve; 14 –...

  • Page 18

    1 – water consumption regulator ; 2 – gas consumption regulator; 3 – water temperature display; 4 – water and gas block; 5 – burner; 6 – cold water inlet; 7 – gas inlet; 8 – hot water outlet; 9 – gas removal device; 10 – ignition plug; 11 – flame sensor; 12 – heat exchanger; 13 – electromagnetic val...

  • Page 19

    9. Possible failures and methods of their elimination table 6. Possible failures of «baltgaz neva-4511» failure probable cause methods of elimination when the hot water tap is opened the appliance does not switch, there is no electric spark. The batteries are not installed into the battery secton (o...

  • Page 20

    Failure probable cause methods of elimination water temperature is shown on display for a short time, and then letters «ЕЕ» appear. Nected (the contacts are disrupted). (restore the contacts).* the water temperature sensor is out of ser- vice. Effect the water temperature sensor’s replacement.* unsu...

  • Page 21

    12. Technical service in order to provide long-term and failure-free operation of the appliance and to keep its operating characteristics it is necessary to regularly effect the examination, treatment and technical service. In order to provide fire safety it is necessary to be on the outlook for the...

  • Page 22

    B) hold it in the solution for 10-15 minutes and effect cleaning of dirty surfaces with the help of a soft brush, then wash it with a strong water stream; c) if necessary repeat the whole process. In order to remove scale deposit it is necessary to: a) remove the heat exchanger and put it into a tan...

  • Page 23

    Bubble test for gas and visual examination for water (see p. 7.3.7 и 7.4.5). 13.4. Water and gas block replacement 13.4.1. Remove the casing, see p.13.1. 13.4.2. Disconnect three wires from the electromagnetic valve 16. 13.4.3. Disconnect two wires from the micro switch 17 13.4.4. Disconnect the gas...

  • Page 24

    Play and the thremometer ’s readings measuring the hot water temperature at the appliance’s outlet. 13.12. Replacement of micro switch (water flow sensor) 13.12.1. Remove the casing, see p.13.1. 13.12.2. Disconnect two wires from the micro switch 17. 13.12.3. Screw off two screws connecting the micr...

  • Page 25

    Scheme 18. View of the appliance «baltgaz neva-4511» with separated parts.

  • Page 26

    Table 8. Spare parts catalogue of the appliance «baltgaz neva-4511» pos. Name designation quan tity 1 carcass 3272-01.000 1 2 heat exchanger* 3272-07.000 1 3 burner* (10 sections) natural gas (g20, 2 nd family, group Н), 1,3 kpa natural gas (g20, 2 nd family, group Н), 2,0 kpa liquiefied gas (g30, 3...