Barnett Engineering PRO TALK CV2 Instruction Manual

Other manuals for PRO TALK CV2: Instruction Manual
Manual is about: Barnett Engineering Automobile Alarm User Manual

Summary of PRO TALK CV2

  • Page 1

    Instruction manual.

  • Page 2

    Instruction manual 1272m001 manual revision: 9.4 - november 2007.

  • Page 3: Contents

    Contents 1 getting started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1 2 operations overview cv2 capabilities (advanced mode) . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1 what constitutes an alarm? . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....

  • Page 4: Regulatory Notices

    B1272m001 barnett engineering ltd. Protalk cv2 regulatory notices caution the protalk cv2, model b1272d, has been certified by the federal communications commission (“fcc”) using the included articulating dual-band dipole antenna. Unauthorized modifications or changes not expressly approved by barne...

  • Page 5: 1.  Getting Started

    Getting started 1-1 b1272m001 barnett engineering ltd. Protalk cv2 1. Getting started the cv2 is a very flexible device capable of monitoring discrete or analog inputs and reporting alarm conditions at these inputs. It is also capable of controlling multiple outputs. Before the cv2 is placed into se...

  • Page 6

    Getting started 1-2 b1272m001 barnett engineering ltd. Protalk cv2 single function called controls. The number of directories is reduced from 6 to 2 in basic mode. It is possible to retain the advanced directory commands even if the overall programming is set for basic operation. It is important to ...

  • Page 7

    Getting started 1-3 b1272m001 barnett engineering ltd. Protalk cv2 table 1 mode comparison function advanced mode basic mode input debounce independent for each input part of alarms - same setting for all input no/nc independent for each input part of alarms - same setting for all input type 8 input...

  • Page 8: 2.  Operations Overview

    Operations overview 2-1 b1272m001 barnett engineering ltd. Protalk cv2 2. Operations overview the purpose of this chapter is to provide an overview of the cv2 capabilities. Chapter topics are organized in the same order that you would follow in setting up the system. For more details on configuring ...

  • Page 9

    Operations overview 2-2 b1272m001 barnett engineering ltd. Protalk cv2 hardware inputs 8 inputs 8 outputs points up to 30 inputs or outputs group 1 cell phone hardware outputs group 6 directory a directory f dialout commands control commands figure 1 cv2 block diagram - advanced mode “high” or low” ...

  • Page 10

    Operations overview 2-3 b1272m001 barnett engineering ltd. Protalk cv2 2.1.4 what actions should occur when an alarm is detected? All alarm conditions will be processed by placing a call on the cellular phone. The called number and the activities that occur with different alarms are determined by en...

  • Page 11

    Operations overview 2-4 b1272m001 barnett engineering ltd. Protalk cv2 alarm before the cv2 advances to the next line in the directory. This can be done by using the wait command on its own line; the entry below will cause a four minute delay before the next line is executed. 1. [dial]2458829 [wait]...

  • Page 12

    Operations overview 2-5 b1272m001 barnett engineering ltd. Protalk cv2 allowing access to alarm information or other control functions. At the highest level, the call is answered but there are no voice prompts; the caller has ten seconds to enter the access code. Each group of alarms has its own int...

  • Page 13

    Operations overview 2-6 b1272m001 barnett engineering ltd. Protalk cv2 alarms 8 inputs 8 outputs cell phone outputs directory a directory b dialout commands control commands 5 hardware controlled 3 user controlled acknowledge interrogate access figure 2 cv2 block diagram - basic mode 2.2.1 what cons...

  • Page 14

    Operations overview 2-7 b1272m001 barnett engineering ltd. Protalk cv2 2.2.4 how do you want to respond to an alarm call? After the cv2 has finished speaking the alarm messages, it prompts the called party with the phrase “enter acknowledge code” and then waits five seconds for the code to be return...

  • Page 15

    Operations overview 2-8 b1272m001 barnett engineering ltd. Protalk cv2 2.3 indicators the cv2 has four led indicators to show the operation of the unit and to assist in troubleshooting. When the cv2 is initially powered up, the four leds will do the following: c all will turn on for approximately on...

  • Page 16

    Operations overview 2-9 b1272m001 barnett engineering ltd. Protalk cv2 are the inputs connected properly? For digital inputs that are programmed for standard digital operation, create an alarm condition on the input and confirm that the alarm led comes on. Make sure the input is applied long enough ...

  • Page 17: Installation

    Installation 3-1 b1272m001 barnett engineering ltd. Protalk cv2 figure 3 packaged cv2 3 installation the cv2 can be installed before or after the configuration has been transferred from the pc to the unit. If the cv2 is configured in the shop before it is installed in the field, all of the programme...

  • Page 18

    Installation 3-2 b1272m001 barnett engineering ltd. Protalk cv2 figure 4 stand-alone cv2 figure 5 ground closure input wiring 3.2.2 stand-alone model the stand-alone cv2 can be mounted on a flat surface. Make sure that there is enough room around the unit to make connections. The environment should ...

  • Page 19

    Installation 3-3 b1272m001 barnett engineering ltd. Protalk cv2 figure 6 +12 volt input wiring figure 7 +5 vdc input wiring figure 9 analog (unfiltered) input wiring figure 8 analog (filtered) input wiring 3.3.2 +12 volt alarm signal the input will accept an alarm signal that switches between 0 and ...

  • Page 20

    Installation 3-4 b1272m001 barnett engineering ltd. Protalk cv2 figure 10 output wiring figure 11 serial cable 3.4 output port connections the output ports are open collector drivers that can sink up to 500 ma through a load connected to a voltage of up to +50 vdc. If an inductive load such as a rel...

  • Page 21

    Installation 3-5 b1272m001 barnett engineering ltd. Protalk cv2 figure 12 stand-alone cv2 figure 13 packaged cv2.

  • Page 22: Configuration Using The Pc

    Configuration using the pc 4-1 b1272m001 barnett engineering ltd. Protalk cv2 4 configuration using the pc this chapter describes how to install the programming software and configure the operation of the cv2. When the configuration is complete, it can be viewed through the summary command found on ...

  • Page 23

    Configuration using the pc 4-2 b1272m001 barnett engineering ltd. Protalk cv2 4.5 program functions - advanced mode the menu and taskbar for the advanced mode is shown below: file operations file open if you do not want to edit the default database, use the file open button to select a different con...

  • Page 24

    Configuration using the pc 4-3 b1272m001 barnett engineering ltd. Protalk cv2 groups each of the six groups can be set to provide different alarm reporting operations for selected points. Points in the points section, any of the hardware inputs and outputs can be selected for the cv2 to use as alarm...

  • Page 25

    Configuration using the pc 4-4 b1272m001 barnett engineering ltd. Protalk cv2 way to get the unit operational when in the advanced mode. If the cv2 uses any of the special port functions -- alarm active, new alarm, acknowledge received, local acknowledge or the totalizer reset input -- you must cons...

  • Page 26

    Configuration using the pc 4-5 b1272m001 barnett engineering ltd. Protalk cv2 watchdog interval timer. Refer to the preceding digital input description for details on the debounce timer. Two watchdog time ranges, seconds and minutes, are available. The seconds range has a maximum value of 1638 secon...

  • Page 27

    Configuration using the pc 4-6 b1272m001 barnett engineering ltd. Protalk cv2 two timer ranges, seconds and minutes, are available. The seconds range has a maximum value of 1638 seconds (27 minutes) with a resolution of 25 msec. For longer times the minutes range should be used. When set to minutes,...

  • Page 28

    Configuration using the pc 4-7 b1272m001 barnett engineering ltd. Protalk cv2 output used to indicate that the phone is ringing. Output used to indicate that the modem is in the connected state. Default port selection: unused, not included in any reporting activities. Point name the point name is a ...

  • Page 29

    Configuration using the pc 4-8 b1272m001 barnett engineering ltd. Protalk cv2 decimal place a decimal place can be inserted into the spoken message for a totalizer. Five decimal locations are available: xxxxx. Xxxx.Y xxx.Yy xx.Yyy x.Yyyy when the message is spoken, the digits to the left of the deci...

  • Page 30

    Configuration using the pc 4-9 b1272m001 barnett engineering ltd. Protalk cv2 announced in engineering units. Calibrate is a secondary dialog box that is activated from the analog point dialog box. The relationship between the binary reading from the input analog converter and the decimal value that...

  • Page 31

    Configuration using the pc 4-10 b1272m001 barnett engineering ltd. Protalk cv2 minimum: 0 maximum: +100.0 low setpoint: +25.0 high setpoint: +75.0 hysteresis hysteresis is a quick method of establishing the reset values for the high and low setpoints. After an analog reading has exceeded the setpoin...

  • Page 32

    Configuration using the pc 4-11 b1272m001 barnett engineering ltd. Protalk cv2 interval, the output port may have returned to the off state before the announcement is made. This code can be 1 to 7 digits in length and may use any of the 16 dtmf digits including a, b, c, and d. Default dtmf on code: ...

  • Page 33

    Configuration using the pc 4-12 b1272m001 barnett engineering ltd. Protalk cv2 interrogate code the interrogate code is a 1 to 7 digit dtmf string that is used to make the cv2 announce the condition of points in the group. Each group can have a unique interrogate code, or different groups can use th...

  • Page 34

    Configuration using the pc 4-13 b1272m001 barnett engineering ltd. Protalk cv2 this code can be 1 to 7 digits in length and may use any of the 16 dtmf digits including a, b, c, and d. Default shift selection: directory a for all shifts. Special function outputs outputs can be assigned to indicate ce...

  • Page 35

    Configuration using the pc 4-14 b1272m001 barnett engineering ltd. Protalk cv2 in a line-by-line format. A line represents one complete action, usually a cellular call. Edit the highlighted line by pressing enter, double-clicking on the line, or selecting the edit line command from the menubar in th...

  • Page 36

    Configuration using the pc 4-15 b1272m001 barnett engineering ltd. Protalk cv2 separated by 100 msec of quiet. Alert must be preceded by a dial command; it cannot be the first entry in the list. It can be used more than once in a list. Voice the voice command causes stored voice messages for the sit...

  • Page 37

    Configuration using the pc 4-16 b1272m001 barnett engineering ltd. Protalk cv2 level 2 when the incoming call is answered by the cv2, only the site id is announced; for further access to the cv2 the caller must enter the access code. Level 3 an incoming call results in the cv2 coming off-hook with n...

  • Page 38

    Configuration using the pc 4-17 b1272m001 barnett engineering ltd. Protalk cv2 ring output ring output is used to select one of the eight outputs to externally indicate that there is an incoming call. The output will follow the ringing cadence if selected. Default ring output: none modem cd modem ca...

  • Page 39

    Configuration using the pc 4-18 b1272m001 barnett engineering ltd. Protalk cv2 configuration data to transfer configuration data, use the two buttons in the configuration box. Press the write to cv2 button to transmit the configuration database from the pc into the cv2 or press the read from cv2 but...

  • Page 40

    Configuration using the pc 4-19 b1272m001 barnett engineering ltd. Protalk cv2 4.8.2 control section use the control section to configure the hardware outputs if the cv2 is going to be used for remote control. Three of the control outputs are user programmable and can be individually set for either ...

  • Page 41

    Configuration using the pc 4-20 b1272m001 barnett engineering ltd. Protalk cv2 keeping the rest of the configuration in basic mode. Insert - insert a new phone number at the highlighted location delete - delete the phone number at the highlighted location edit - modify the phone number at the highli...

  • Page 42: Remote Data Access

    Remote data access 5-1 b1272m001 barnett engineering ltd. Protalk cv2 figure 14 - data cable for external equipment 5 remote data access external equipment connected to the serial port can be accessed by calling the cv2 with a remote modem. The cv2 can determine whether the data is intended for a re...

  • Page 43

    Voice storage and configuration with the telset 6-1 b1272m001 barnett engineering ltd. Protalk cv2 6 voice storage and configuration with the telset 6.1 setup the cv2 can be configured by transferring a database from the pc, either in basic or advanced mode, or by using the programming phone. All of...

  • Page 44

    Voice storage and configuration with the telset 6-2 b1272m001 barnett engineering ltd. Protalk cv2 directory programming, where the called numbers are entered, requires care to ensure that these numbers are valid. If the cv2 is unable to successfully complete calls it will take action to ensure that...

  • Page 45

    Voice storage and configuration with the telset 6-3 b1272m001 barnett engineering ltd. Protalk cv2 6.4 telset programming summary a cv2 is set for basic mode programming when it is shipped. The only way to change it to the advanced mode is by using the pc configuration software. The different sequen...

  • Page 46

    Voice storage and configuration with the telset 6-4 b1272m001 barnett engineering ltd. Protalk cv2 6.5 programming flowchart voice menu (basic and advanced mode) cv2: “enter voice code” you: playback or record voices for site id and groups 1 to 6 playback or record voices for alarm inputs 1 to 8 (ba...

  • Page 47

    Voice storage and configuration with the telset 6-5 b1272m001 barnett engineering ltd. Protalk cv2 directory line cv2: “directory a line 1 is dial 2559545 voice” you: edit current line delete current line edit a new line to be inserted before current line exit to directory menu accept current line a...

  • Page 48

    Voice storage and configuration with the telset 6-6 b1272m001 barnett engineering ltd. Protalk cv2 turn call progress detector on exit to main menu accept call progress control and advance to access code access code cv2: “access code is empty” you: change access code to 11 (max 8 digits) erase acces...

  • Page 49

    Voice storage and configuration with the telset 6-7 b1272m001 barnett engineering ltd. Protalk cv2 exit to main menu accept alarm format and advance to debounce scale debounce scale cv2: “alarm timer is seconds” you: change debounce scale to seconds change debounce scale to minutes exit to main menu...

  • Page 50

    Voice storage and configuration with the telset 6-8 b1272m001 barnett engineering ltd. Protalk cv2 control timer scale cv2: “control timer is seconds” you: change timer scale to seconds change timer scale to minutes exit to main menu accept timer scale and advance to control timer value control time...

  • Page 51

    Voice storage and configuration with the telset 6-9 b1272m001 barnett engineering ltd. Protalk cv2 transceiver state cv2: “code five is 8 1” you: exit to main menu advance to query channel / power channel / power cv2: “code six is 1 2 3 point 4 5" you: exit to main menu advance to query service opti...

  • Page 52: 7 Voice Editor

    Voice editor 7-1 b1272m001 barnett engineering ltd. Protalk cv2 7 voice editor 7.1 voice editor access to the voice editor is through the drop-down file menu. The voice editor is a utility for manipulating and organizing the individual phrases that the cv2 uses to identify groups, points and the sit...

  • Page 53

    Voice editor 7-2 b1272m001 barnett engineering ltd. Protalk cv2 controls in the voice editor dialog box are: individual voice phrase section hardware the setting of the tab control at the bottom of the box determines which part of the message configuration is shown in the phrase list boxes. Use text...

  • Page 54

    Voice editor 7-3 b1272m001 barnett engineering ltd. Protalk cv2 message file section load a file open dialog box is used to select the required message file with the .Msg extension. Message files contain the phrases used by the cv2 to identify site id, groups and points. If there are individual phra...

  • Page 55

    Voice editor 7-4 b1272m001 barnett engineering ltd. Protalk cv2 7.2 wave file conversion access to the wave file converter is through the drop-down file menu. The cv2 uses adaptive differential pulse code modulation (adpcm) operating at 32 kbps to convert audio signals to digital form. Adpcm convert...

  • Page 56: 8  Specifications

    Specifications 8-1 b1272m001 barnett engineering ltd. Protalk cv2 8 specifications 8.1 general alarm inputs • 8 inputs: analog or digital, latching or momentary; plug in screw terminal block. • analog: 0 to 5 vdc, 100k input impedance • digital: normally open or normally closed, ground closure or +1...

  • Page 57

    Specifications 8-2 b1272m001 barnett engineering ltd. Protalk cv2 intervals are adjustable from 1 to 249 minutes; the short timer can be used from 1 to 9 times. Acknowledge code • stops the transmission cycle when received. 1 to 7 dtmf digits with individual codes allowed for each group. Interrogate...

  • Page 58

    Cellphone status codes 9-1 b1272m001 barnett engineering ltd. Protalk cv2 9 cellphone status codes following is summary of the transceiver codes that can returned to the telset from the cellphone configuration section. 9.1 received signal strength indicator - rssi (code 1) speaks “code one is 8, 8, ...

  • Page 59

    Cellphone status codes 9-2 b1272m001 barnett engineering ltd. Protalk cv2 9.6 channel / power (code 6) speaks “code six is abc point de”, where abc = current transceiver center frequency channel de = current transmitter power (negative dbm) 9.7 service option / protocol revision (code 7) speaks “cod...

  • Page 60

    Cellphone status codes 9-3 b1272m001 barnett engineering ltd. Protalk cv2 9.8 extended state/ drop reason/ online mode (code 8) speaks “code eight is a point bc point d”, where: a = power available 0: no power to transceiver 1: module power is on bc = call dropped reason 00: phone is offline 01: pho...

  • Page 61

    Warranty 10-1 b1272m001 barnett engineering ltd. Protalk cv2 10 warranty barnett engineering ltd. Warrants that all equipment supplied shall be free from defects in material or workmanship at the time of delivery. Such warranty shall extend from the time of delivery for a period of one year. Buyer m...