C&H AIR-MASTER SeriesCH-S07RX4 Owner's Manual - Precautions

Manual is about: Split Air Conditioner

Summary of AIR-MASTER SeriesCH-S07RX4

  • Page 1

    Split air conditioner air-master series owner’s manual designed by cooper&hunter international corporation, oregon, usa www.Cooperandhunter.Com f or proper operation, please read and keep this manual carefully. Models : ch-s07rx4 ch-s09rx4 ch-s12rx4 ch-s18rx4 ch-s24rx4.

  • Page 2: Content

    This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children ...

  • Page 3: Precautions

    1 precautions warning do not connect air conditioner to multi-purpose socket. This appliance can be used by children aged from 8 operation and maintenance if the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a haza...

  • Page 4: Precautions

    Do not block air outlet or air inlet. It may cause malfunction. Remote controller may be broken. ● power cord is overheating or damaged. ● there’s abnormal sound during operation. ● circuit break trips off frequently. ● air conditioner gives off burning smell. ● indoor unit is leaking. Contact the d...

  • Page 5: Precautions

    Do install the circuit break. If not, it may cause malfunction. Of at least 3mm in all poles should be connected in fixed wiring. Magnet buckle and heating buckle function, it can protect the circuit-short and overload. Power supply circuit and circuit break. 3 precautions warning note the following...

  • Page 6: Precautions

    Installation must be performed in accordance with the persons in order to avoid a hazard. Must be properly grounding with specialized grounding device by a professional. Please make sure it is always grounded effectively, otherwise it may cause electric shock. The appliance must be positioned so tha...

  • Page 7: Precautions

    The indoor unit should be installed close to the wall. reachable after finishing installation. Far away from animals or plants.If it is unavoidable, please add the fence for safety purpose. 5 precautions warning place, only the qualified person can perform the work. Otherwise, it may cause personal ...

  • Page 8: Parts Name

    6 (display content or position may be different from above graphics, please refer to actual products) parts name indoor unit outdoor unit air inlet panel aux.Button horizontal louver air outlet heating indicator temp. Indicator cooling indicator power indicator receiver window drying indicator displ...

  • Page 9: Buttons On Remote Controller

    7 buttons on remote controller introduction for icons on display screen operation mode auto mode cool mode dry mode fan mode heat mode clock sleep mode set fan speed send signal x-fan mode set temperature turbo mode set time t i m e r o n / t i m e r off child lock light up&down swing temp. Display ...

  • Page 10

    8 introduction for buttons on remote controller 1 on/off button caution: after putting through the power, the air conditioner will give out a sound. Operation indictor " " is on (red indicator). After that, you can operate the air conditioner by using remote controller. Pressing this button can turn...

  • Page 11

    9 introduction for buttons on remote controller 3 " + " or " - " button ● pressing "+" or "-" button once increases or decreases set temperature 1℃ holding "+" or "-" button, 2s later, set temperature on remote controller will change quickly. On change accordingly. (temperature can’t be adjusted und...

  • Page 12

    10 introduction for buttons on remote controller 6 clock button press this button to set clock time. " " icon on remote controller will blink. Press "+" or "-" button within 5s to set clock time. Each pressing of "+" or "-" button, clock time will increase or decrease 1 minute. Hold "+" or "-" butto...

  • Page 13

    11 introduction for buttons on remote controller note: ● when x-fan function is on, if the air conditioner is turned off, indoor fan will still operate at low speed for a while to blow the residual water inside the air duct. ● during x-fan operation, press x-fan button to turn off x-fan function. In...

  • Page 14: Operation Guide

    12 function introduction for combination buttons child lock function: press "+"and "-" simultaneously to turn on or turn off child lock function. When child lock function is on," " icon is displayed on remote controller. If you operate the remote controller, it won’t send signal. Temperature display...

  • Page 15: Emergency Operation

    13 emergency operation if remote controller is lost or damaged, please use auxiliary button to turn on or turn off the air conditioner. The operation in details are as below: as shown in the fig. Open panel, press aux. Button to turn on or turn off the air conditioner. When the air conditioner is tu...

  • Page 16: Clean and Maintenance

    14 clean and maintenance clean filter 1 2 3 4 open panel remove filter clean filter install filter pull out the panel to a certain angle as shown in the fig. Remove the filter as in- dicated in the fig. ● use dust catcher or water to clean the filter. ● when the filter is very dirty, use the water (...

  • Page 17: Clean and Maintenance

    15 clean and maintenance checking before use-season checking after use-season 1. Check whether air inlets and air outlets are blocked. 2. Check whether air switch, plug and socket are in good condition. 3. Check whether filter is clean. 4. Check whether mounting bracket for outdoor unit is damaged o...

  • Page 18: Malfunction Analysis

    16 malfunction analysis general phenomenon analysis please check below items before asking for maintenance. If the malfunction still can’t be eliminated, please contact local dealer or qualified professionals. Phenomenon check items solution indoor unit can’t receive remote controller’s signal or re...

  • Page 19: Malfunction Analysis

    17 malfunction analysis ● power failure? ● is plug loose? ● air switch trips off or fuse is burnt out? ● wiring has malfunction? ● unit has restarted immediately after stopping operation? ● whether the function setting for remote controller is correct? ● reset the function. ● wait for 3min, and then...

  • Page 20: Malfunction Analysis

    18 phenomenon check items solution odours are emitted ● whether there’s odour source, such as furniture and cigarette, etc. ● eliminate the odour source. ● clean the filter. Air conditioner operates nor- mally suddenly ● whether there’s interference, such as thunder, wireless devices, etc. ● disconn...

  • Page 21: Malfunction Analysis

    19 malfunction analysis error code e5 u8 h6 c5 f1 f2 troubleshooting it can be eliminated after restarting the unit. If not, please it can be eliminated after restarting the unit. If not, please it can be eliminated after restarting the unit. If not, please error code ● when air conditioner status i...

  • Page 22

    20 installation dimension diagram drainage pipe at least 250cm at least 15cm at least 50cm at least 30cm at least 300cm space to the obstruction space to the obstruction space to the obstruction sp ac e to th e ce ilin g space to the obstruction space to the obstruction at least 30cm at least 15cm a...

  • Page 23: Tools For Installation

    21 selection of installation location basic requirement outdoor unit installing the unit in the following pla- ces maycause malfunction. If it is un- avoidable, please consult the local dealer: 1. There should be no obstruction near air inlet and air outlet. 2. Select a location where the condensat-...

  • Page 24: Safety Precaution

    22 requirements for electric connection safety precaution grounding requirement 1. Must follow the electric safety regulations when installing the unit. 2. According to the local safety regulations, use qualified power supply circuit and air switch. 3. Make sure the power supply matches with the req...

  • Page 25: Installation of Indoor Unit

    23 installation of indoor unit step one: choosing installation location step two: install wall-mounting frame recommend the installation location to the client and then confirm it with the client. 1. Hang the wall-mounting frame on the wall; adjust it in horizontal position with the level meter and ...

  • Page 26: Step Four: Outlet Pipe

    24 step five: connect the pipe of indoor unit 1. Aim the pipe joint at the corresponding bellmouth. 2. Pretightening the union nut with hand. 3. Adjust the torque force by referring to the following sheet. Place the open-end wrench on the pipe joint and place the torque wrench on the union nut. Tigh...

  • Page 27: Step Six: Install Drain Hose

    25 nection pipe with insulating pipe, and insulating pipe 1. Connect the drain hose to the outlet pipe of outlet pipe drain hose drain hose tape outlet pipe drain hose insulating pipe ● add insulating pipe in the indoor ● the plastic expansion particles are 1. Open the panel, remove the screw on the...

  • Page 28: Installation of Indoor Unit

    26 4. Put wiring cover back and then tighten the screw. 5. Close the panel. Installation of indoor unit note: ● all wires of indoor unit and outdoor unit should be connected by a professional. ● if the length of power connection wire is insufficient, please contact the supplier for a new one. Avoid ...

  • Page 29: Installation of Indoor Unit

    27 installation of indoor unit step eight: bind up pipe 1. Bind up the connection pipe, power cord and drain hose with the band. Indoor unit gas pipe indoor and outdoor power cord liquid pipe drain hose band 2. Reserve a certain length of drain hose and power cord for installation when binding them....

  • Page 30: Installation of Outdoor Unit

    28 installation of outdoor unit step one: fix the support of outdoor unit (select it according to the actual installation situation) 1. Select installation location according to the house structure. 2. Fix the support of outdoor unit on the selected location with expansion screws. At least 3cm above...

  • Page 31: Installation of Outdoor Unit

    29 yellow- green installation of outdoor unit step four: connect indoor and outdoor pipes 1. Remove the screw on the right han- dle of outdoor unit and then remove the handle. 2. Remove the screw cap of valve and aim the pipe joint at the bellmouth of pipe. 3. Pretightening the union nut with hand. ...

  • Page 32: Step Six: Neaten The Pipes

    30 step six: neaten the pipes 1. The pipes should be placed along the wall, bent reasonably and hidden possibly. Min. Semidiameter of bending the pipe is 10cm. 2. If the outdoor unit is higher than the wall hole, you must set a u-shaped curve in the pipe before pipe goes into the room, in order to p...

  • Page 33: Vacuum Pumping

    31 vacuum pumping leakage detection 1. Remove the valve caps on the liquid valve and gas valve and the nut of refri- gerant charging vent. 2. Connect the charging hose of piezometer to the refri- gerant charging vent of gas valve and then connect the other charging hose to the vacuum pump. 3. Open t...

  • Page 34: Check After Installation

    32 check after installation test operation ● check according to the following requirement after finishing installation. Items to be checked possible malfunction has the unit been installed firmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? It may cause insuff...

  • Page 35

    33 configuration of connection pipe 1. Standard length of connection pipe ● 5m, 7.5m, 8m. 4. The additional refrigerant oil and refrigerant charging required after prolonging connection pipe ● after the length of connection pipe is prolonged for 10m at the basis of standard length, you should add 5m...

  • Page 36

    34 additional refrigerant charging amount for r22, r407c, r410a and r134a diameter of connection pipe liquid pipe(mm) gas pipe(mm) Φ6 Φ6 or Φ9.52 Φ9.52 or Φ12 Φ12 Φ16 Φ19 Φ22.2 Φ16 or Φ19 Φ19 or Φ22.2 Φ25.4 or Φ31.8 _ _ cooling only(g/m) cooling and heating(g/m) 15 15 30 60 250 250 350 350 120 120 5...

  • Page 37: Pipe Expanding Method

    35 pipe expanding method note: improper pipe expanding is the main cause of refrigerant leakage. Please expand the pipe according to the following steps: a: cut the pipe ● confirm the pipe length according to the distance of indoor unit and outdoor unit. ● cut the required pipe with pipe cutter. Pip...

  • Page 38

    Designed by cooper&hunter international corporation, oregon, usa www.Cooperandhunter.Com e-mail: info@cooperandhunter.Com 66129915261.