C&K Systems active 5 Engineering Manual - page 5

Other manuals for active 5: User Manual

Summary of active 5

  • Page 1

    Active 5 engineering manual c & k systems ltd c031-066 issue 3.

  • Page 2

    C&k securitech 1 the active 5 installation manual. Date: feb 1997 introduction. The active 5 is a microprocessor controlled intruder alarm panel. It features five zones all of which are programmable. A non volatile memory holds the programming options. These will be retained in total power failure. ...

  • Page 3

    C&k securitech 2 factory defaults user / customer code 1 1234 engineer code 7890 circuit 1 personal attack (pa) circuit 2 alarm circuit circuit 3 alarm circuit isolated in home set circuit 4 alarm circuit with walkthrough circuit 5 entry / exit circuit full set exit time 30 seconds night set exit ti...

  • Page 4

    C&k securitech 3 mounting a remove the lid screws and remove lid. B unplug any cables connected to the pcb c remove the pcb. D place the panel in the selected position and mark the three fixing holes. E mount the panel securely using all three positions. F replace pcb and reconnect all cabling. Wiri...

  • Page 5

    C&k securitech 4 4 pir latch line (l+) in the event of two or more pir detectors being fitted to any zone, latching detectors can be used. The 'l+' connection provides this function. It is low (0v) when unset and high (12 v) when set. 5 detector reset (id) some detectors require the removal of power...

  • Page 6

    C&k securitech 5 8 aux dc detector power. The auxiliary power is provided from connections marked 'aux'. This is to provide the 12 v supply for detectors e.G. Pir's. The auxiliary power output is rated 500 ma max. (12 v nominal). **please note bellbox connections at rear of manual** mounting a remot...

  • Page 7

    C&k securitech 6 i) timed exit can be used by simply programming the time you wish using the 3-0 and 3-3 options. Ii) exit terminate is achieved by connecting the push button across s+ and s2 and program option 7-3-1 from engineering mode. Make sure you link s1 to s+. This will stop the panel seeing...

  • Page 8

    C&k securitech 7 initial power up note the lid should be kept off the main control panel. The keypad tamper may also be used to enter engineer mode. I switch the mains supply on, the internal sounder will start. Ii enter 1 2 3 4 followed by # button, this will silence the sounder and the tamper led ...

  • Page 9

    C&k securitech 8 option 3-0 exit time 5-105 seconds. Default. 30 secs. Enter 3-0 - led 6 will light up. This has been preset for factory default - at 30 seconds. A new time may be programmed by entering the relevant keys which total up to make the required time multiplied by 5. Once program is set p...

  • Page 10

    C&k securitech 9 circuit programming matrix reference guide led 1 led 2 led 3 led 4 led 5 led 6 tamper led alarm isolate in home set isolate in night set walk through entry route chime isolate permit full set entry zone night set entry zone walk through entry route chime isolate permit 24 hour zone ...

  • Page 11

    C&k securitech 10 24 hour zone. This zone type is active 24 hours a day irrespective of whether the control panel is armed or disarmed. In the armed condition it will signal a full alarm if triggered. In the disarmed condition it will give a local internal alarm warning only. Fire. A 24 hour type of...

  • Page 12

    C&k securitech 11 warning tone . A 24 hour zone option which, following and alarm in the day condition, allows the internal alarm sounder tone to be changed to a rapid beeping. This will give a differential to other day time alarms. Example to program zone 1 enter 4-1. The tamper led will show progr...

  • Page 13

    C&k securitech 12 7-x options. The 7 options controls how the panel responds to given criteria. Some options only apply if a communicator is fitted (active 5x only) these are marked with a ⊗ . Option 7-0. Night set options. 70-1 night set disable 70-2 disable bells in night set 70-3 ⊗ disable commun...

  • Page 14

    C&k securitech 13 option 7-4. European options. 74-1 flash the led relating to a zone if that zone if it is open when the control panel is in an unset condition 74-2 ⊗ 2 stage communicator output 74-3 10 minute auto isolate of an open zone when set. 74-4 blockschloss - german setting method. Bellbox...

  • Page 15

    C&k securitech 14 zone zone use / location resistance keys entered 1 Ω Ω 2 Ω Ω 3 Ω Ω 4 Ω Ω 5 Ω Ω timer value keys entered full seconds night seconds ext sounder minutes delay minutes tick box 1 2 3 4 checked night set options home set options engineer options line fault options european options batt...