C Security Systems c-pod Installation Manual - Installation Manual
9
The
activation button
should be dis-
creetly located inside the area pro-
tected by the magnetic intrusion sen-
sor, so that it can be reached within
45 seconds of entering the boat to
deactivate the alarms. The button
has a LED indicator in the center
which must be visible. Connect the
button to the contact marked
I/O
on
the C-pod.
Attach the
magnetic intrusion sensor
to the desired door or hatch. When
the door or hatch is closed the gap
between the magnet (no cable) and
the reed switch (with cable) must not
exceed 15 mm to avoid an unstable
operation and false alarms. Connect
the magnetic intrusion sensor to the
contact marked
1
on the C-pod.
Installation Manual
2.
Installing the system (continued)
max 15 mm
Note:
If you choose not to install the magnetic intrusion sensor, refer
to section 5b.
Note:
If you have purchased optional accessories refer to section 5c.