D'Amore Engine'ring SMDOM-1 User Manual - Thank You

Summary of SMDOM-1

  • Page 1

    Om-1 output level meter.

  • Page 2: Thank You

    Thank you congratulations on your purchase of the smd / d’amore engineering om-1. This unit is designed and manufactured in the usa with pride. A word of caution: this product has exposed circuitry and components on it. Damage can result from static discharge into the circuit board. Please handle wi...

  • Page 3: Specifications

    Specifications operating voltage range for power supply 7 – 28 vdc operating voltage range for remote turn on 3 – 28 vdc voltage required on speaker input for full scale @ maximum sensitivity ………………………………….10 vac rms voltage required on speaker input for full scale @ minimum sensitivity…………………………………...

  • Page 4

    Calibration with distortion detector dd-1 1. Disconnect speakers from amplifier 2. Connect om-1 as described in installation section. 3. Connect dd-1 to amplifier output 4. Play track 3 or 4 from distortion detector cd (track 3 for subwoofer amplifier, track 4 for full range amplifier), set track to...

  • Page 5: Troubleshooting

    Calibration without distortion detector dd-1 1. Connect om-1 as described in installation section. 2. Play music as loud as possible without damaging your system or distorting the sound. 3. Carefully, with small adjustment screwdriver, turn the adjustment pot on the om-1 fully counter clockwise. The...

  • Page 6

    Problem: the meters do not return to the - ∞ position even when no audio signal is present. Solution: there may be noise in the system or the amplifier has some dc offset on the output. If dc offset is the problem, it may be necessary to place a capacitor in series with white or grey wire to filter ...

  • Page 7: Limited Warranty

    Limited warranty d’amore engineering warrants this product to be free of defects in materials and workmanship for a period of one year. This warranty is not transferrable and applies only to the original purchaser from an authorized d’amore engineering dealer. Should service be necessary under this ...

  • Page 8

    D’amore engineering om-1 owner’s manual rev. 1 2013 printed in phoenix, arizona.