Dacor DCM24 Planning Manual
PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
CI.22
Microwave/Discovery Wall Oven/
Warming Drawer
COMBINATION INSTALLATIONS
CUTOUT DIMENSIONS
DMT2420 ShOWN
CUTOUT DIMENSIONS
DCM24 ShOWN
Wall Oven
Models
(B) Cutout Width
Single 27”
25 1/2” (648 mm)
Single 30”
28 1/2” (724 mm)
Microwave
Model No.
(A) Cutout Width
DMT2420 w/AOMTK series trim kit
24 3/8” (619 mm)
DCM24 w/AOCTK27 trim kit
25 1/4” (641 mm)
DCM24 w/AOCTK30 trim kit
25 1/4” (641 mm)
Warming
Drawer
Models
(C) Cutout Width
27”
25 1/2” (648 mm)
30”
28 1/2” (724 mm)
NOTE:
3/4” (19 mm) support platform (flush with cutout).
1.
See individual appliance Planning Guide pages to
2.
determine overlays.
Spacing between appliances and drawers/doors shown
3.
is minimum required to allow for ventilation and prevent
scraping. Additional space may need to be added for
appearance.
Warming drawer model OWD24 is not approved for
4.
installation below a wall oven.
9 1/8”
(232 mm)
27 1/2”
(699 mm)
16 3/4”
(425 mm)
1 1/2” Min.
(38 mm)
2 1/4” Min.
(57 mm)
B
C
A
1
1
1
7/8” Min. (22 mm)
3/4” Min.
(19 mm)
58 3/4”
Min.
(1492 mm)
overall
stacked
height
120 Vac electrical
outlet for microwave
120 Vac electrical
drawer
240 Vac
wall oven
junction box
outlet for warming
9 1/8"
(232 mm)
27 1/2"
(699 mm)
18 1/2”
(470 mm)
1 3/4" Min.
(44 mm)
2 1/4" Min.
(57 mm)
B
A
1
1
1
7/8" Min. (22 mm)
3/4" Min.
(19 mm)
60 3/4"
Min.
(1543 mm)
overall
stacked
height
C
120 Vac electrical
outlet for microwave
120 Vac electrical
drawer
240 Vac
wall oven
junction box
outlet for warming
All tolerances: +1/16”, -0, (+1.6 mm, -0) unless otherwise stated
Document # PGCI - 018
Revised 11/05/09 Page 1/1
WArNING
Observe all governing codes and ordinances during
•
planning and installation. Contact your local building
department for further information.
All appliances must be installed in accordance with the
•