Dacor Millennia AFM36VSP Planning Manual
PLANNING
GUIDE
11.3
Specifications subject to change without notice.
Phone: (800) 793-0093
www.dacor.com
36 Inch Wide, Glass Door
Freestanding Refrigerator
PF36BNDF
Product Dimensions
◊
Thedepthfromthefrontofthedoor(w/odoorhandles)tothebackof
therefrigeratorchassisis267/8”(68.3cm).
◊
Thedepthofthecabinetlessthedooris241/8”(61.3cm).
◊
Theheightfromthetopoftherefrigeratortothefloorwiththeleveling
legsinthedownpositionis701/8”(178.1cm).
◊
Theheightfromthetopoftherefrigeratortothefloorwiththeleveling
legsinthefullyextendedpositionis711/4”(181.0cm)atthefrontof
theunitand7011/16”(179.6cm)attherearoftheunit.
◊
Therefrigeratorwidthfromedgetoedgeis355/8”(90.5cm).
Electrical Requirements
A115Volt,60Hz.AConly15or20Amp.fused,groundedelectricalsupply
isrequired.Itisrecommendedthataseparatecircuitservingonlyyour
refrigeratorbeprovided.Useanoutletthatcannotbeturnedoffbyaswitch.
Donotuseanextensioncord.Thepowercordis60”(152.4cm)long.
Location Requirements
◊
Agroundedthreeprongnon-GFCIelectricaloutletmustbeprovided
andshouldbeinalocationthatallowstherefrigeratortobe
connectedwithoutanextensioncord.SeeElectrical Requirements
foradditionalinformation.
◊
Theplumbingforthewaterlinecancomethroughthefloorflushto
orfromthebackwall.Installthewatervalveinalocationthatallows
ittobeturnedoffwithoutmovingtherefrigeratoroutintheeventthe
refrigeratororwaterlinerequiresservice.
◊
Thelocationmustallowtherefrigeratortobemovedoutfromthe
wallwithoutbeingdisconnectedintheeventthatservicebecome
necessary.
◊
Donotinstalltherefrigeratorinalocationwheretemperatureswillfall
belowfreezing.
◊
Theareatotheleftandtherightoftheappliancemustpermitboth
doorstoopentoaminimumof90°.Allowaminimumof
21/2”(6.4cm)spacebetweenthesideoftherefrigeratordoorsanda
cornerwall.
Water Supply Requirements
◊
Connecttheicemakertoacoldwaterlinewithwaterpressure
between35and120psi.Ifyouhaveanyquestionsaboutyourwater
pressure,callyourutilitycompany.
◊
Use1/4”(6mm)copperlinetoconnecttherefrigeratortothehouse
coldfreshwatersupply.
◊
Installashutoffvalvebetweentherefrigeratorandwatersupply.The
shutoffvalveshouldbeadrilledsaddlevalve.Seethediagramabove
forrecommendedlocation.
◊
Donotuseapiecingtypeor3/16”(5mm)saddlevalvewhichwill
reducewaterflowandclogmoreeasily.
◊
Allowaminimumof24”(61.0cm)diameterserviceloopofcopper
tubingoutsidethewallorfloorforeasyconnectiontothewater
supply.
30”
(76.2 cm)
24”
(61.0 cm)
12” (30.5 cm)
36” min. (91.4 cm)
16”
(40.6 cm)
Water
valve
Electrical
outlet
12”
(30.5 cm)
70 1/2” min.
(179.1 cm)
Reverse Osmosis Water Supply
IMPORTANT:Thepressureofthewatersupplycomingoutofareverse
osmosissystemgoingtothewaterinletvalveoftherefrigeratorneedsto
bebetween35and120psi(241and827kPa).
Ifareverseosmosiswaterfiltrationsystemisconnectedtoyourcoldwater
supply,thewaterpressuretothereverseosmosissystemneedstobea
minimumof40to60psi(276to414kPa).
WARNINg
• Observeallgoverningcodesandordinancesduringplanning
andinstallation.Contactyourlocalbuildingdepartmentfor
furtherinformation.
• Thisappliancemustbeinstalledinaccordancewiththe
accompanyinginstallationinstructions.
Document#PG11-002
Revised08/10/11Page1/1
WATER VALVE AND ELEcTRIcAL oUTLET LocATIoNs
APPRoXIMATE DIMENsIoNs
EPIcURE sTyLE hANDLE DIMENsIoNs (PN AFE36h3)
MILLENNIA sTyLE hANDLE DIMENsIoNs (PN AFM36h3)
B
A
C
A
B
C
A=13/16"(2.1cm)
Brefrigerator=32"(81.3cm)
Bfreezerdrawer=251/2"(64.8cm)
C=23/8"(6.0cm)
A=11/2"(3.8cm)
Brefrigerator=40"(101.6cm)
Bfreezerdrawer=331/2"(85.1cm)
C=21/2"(6.4cm)