ECOPURE EP100 Installation And Operation Manual

Summary of EP100

  • Page 1

    7352262 (rev. A 9/25/15) how to install, operate and maintain your demand controlled water softener do not return water softener to store manufactured and warranted by ecodyne water systems 1890 woodlane drive woodbury, mn 55125 if you have any questions or concerns when installing, operating or mai...

  • Page 2

    2 table of contents page specifications & performance claims . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ...

  • Page 3

    3 specifications & performance claims questions? Call toll free 1-800-693-1138 monday- friday, 7 am - 6 pm cst or visit www.Ecopurewaterproducts.Com when you call, please be prepared to provide the model and serial number, found on the rating decal, located on the rim below the salt lid hinges. * ca...

  • Page 4

    4 do not return the water softener to store. If you have any questions, or there are missing parts or damage, please call toll free 1-800-693-1138 , monday - friday, 7 am - 6 pm cst, or visit www.Ecopurewaterproducts.Com when you call, please be prepared to provide the model and serial number, found...

  • Page 5

    5 packing list inspect shipment water conditioning information iron iron in water can cause stains on clothing and plumb- ing fixtures. It can negatively affect the taste of food, drinking water, and other beverages. Iron in water is measured in parts per million (ppm). The total* ppm of iron, and t...

  • Page 6

    6 plumbing codes all plumbing must be completed in accordance with national, state and local plumbing codes. Air gap requirements a drain is needed for regeneration water (see figure 3). A floor drain, close to the water softener, is preferred. A laundry tub, standpipe, etc. Are other drain options....

  • Page 7

    7 installation requirements valve drain requirements using the flexible drain hose (included), measure and cut to the length needed. Flexible drain hose is not allowed in all localities (check your plumbing codes). If local codes do not allow use of a flexible drain hose, a rigid valve drain run mus...

  • Page 8

    8 installation instructions typical installation turn off water supply 1 . Close the main water supply valve, located near the well pump or water meter. 2 . Shut off the electric or fuel supply to the water heater. 3 . Open all faucets to drain all water from house pipes. Note: be sure not to drain ...

  • Page 9

    9 installation instructions fig. 11 top cover brine tank overflow elbow brine tank overflow grommet 2 cm hole salt lid salt storage tank float stem brine tubing brinewell cover stand tube brine valve brinewell nozzle & venturi assembly fig. 10 turbine turbine support assembly valve outlet fig. 12 cl...

  • Page 10

    10 cold water pipe grounding caution: the house cold water pipe (metal only) is often used as a ground for the house electrical system, the 3-valve bypass type of installation, shown in figure 8, will maintain ground continuity. If you use a plastic bypass valve at the unit, continuity is broken. To...

  • Page 11

    11 installation instructions questions? Call toll free 1-800-693-1138 monday- friday, 7 am - 6 pm cst or visit www.Ecopurewaterproducts.Com when you call, please be prepared to provide the model and serial number, found on the rating decal, located on the rim below the salt lid hinges. Add water and...

  • Page 12

    12 fig. 17 up button display recharge button select button down button fig. 16 when the power supply is plugged into the electrical outlet, a model code and a test number (example: j2.0), begin to flash in the faceplate display. Then, “12:00 pm” and the words “present time" begin to flash. Note: if ...

  • Page 13

    13 set recharge (regeneration) time your demand water softener will automatically regen- erate when it needs to, based on water usage. The time of day that the automatic recharge cycle begins may be changed as follows: 1 . Press the select button once again to display a flashing “2:00am” and the wor...

  • Page 14

    14 adjustable backwash if your incoming water supply has higher sediments or clear water iron, a longer backwash and/or fast rinse time may help in keeping the unit cleaner. To change the length of the backwash: 1 . Press and hold the select button until the screen in figure 25 is displayed. Fig. 25...

  • Page 15

    15 fig. 29 low salt led indicator display select button down button recharge button up button fig. 28 when the power supply is plugged into the electrical outlet, a model code and a test number (example: j2.0), begin to flash in the faceplate display. Then, “12:00 pm” and the words “present time" be...

  • Page 16

    16 fig. 31 set recharge (regeneration) time your demand water softener will automatically regen- erate when it needs to, based on water usage. The time of day that the automatic recharge cycle begins may be changed as follows: 1 . Press the select button once again to display a flashing “2:00am” and...

  • Page 17

    17 adjustable backwash if your incoming water supply has higher sediments or clear water iron, a longer backwash and/or fast rinse time may help in keeping the unit cleaner. To change the length of the backwash: 1 . Press and hold the select button until the screen in figure 38 is displayed. 2 . Pre...

  • Page 18

    18 power outage memory if electrical power to the water softener is lost, “mem- ory'' built into the timer circuitry will keep all settings for several hours. While the power is out, the display is blank and the water softener will not regenerate. When electrical power is restored, the following wil...

  • Page 19

    19 routine maintenance floor drain fig. 43 wood block fig. 42 cap o-ring seal screen support screen gasket *flow plug (hvdc) housing ferrule nut cone screen *flow plug *install with lettered side up, concave side down. Cleaning the nozzle & venturi a clean nozzle & venturi (see figure 42) is a neces...

  • Page 20

    20 troubleshooting guide problem cause correction no soft water 1. No salt in the storage tank. Refill with salt and then use recharge now feature. No soft water & dis- play is blank 1. Power supply unplugged at wall outlet, or power cable disconnected from back of elec - tronic board or power suppl...

  • Page 21

    21 while an error code appears in the display, all buttons are inoperable except the select button. Select remains operational so the service person can per- form the manual advance diagnostics, see below, to further isolate the problem. Procedure for removing error code from dis- play: 1 . Unplug p...

  • Page 22

    22 troubleshooting need help troubleshooting? Call toll free 1-800-693-1138 monday- friday, 7 am - 6 pm cst or visit www.Ecopurewaterproducts.Com when you call, please be prepared to provide the model and serial number, found on the rating decal, located on the rim below the salt lid hinges. Resetti...

  • Page 23

    23 notes.

  • Page 24

    24 8 7 6 5 softener exploded view 13 26 25 27 12 14 15 11 17 18 10 21 22 23 24 7 5 3 8 9 6 valve assembly see pages 26 & 27 for parts 4 2 1 20 19 16.

  • Page 25

    25 softener parts list key no. Part no. Description – 7112963 distributor o-ring kit (includes key nos. 1-3) 1 á o-ring, 73.0 x 82.6 mm 2 á o-ring, 20.6 x 27.0 mm 3 á o-ring, 69.9 x 76.2 mm 4 7077870 top distributor 5 7105047 repl. Bottom distributor – 7331177 tank neck clamp kit (includes key nos. ...

  • Page 26

    26 valve exploded view 51 50 52 53 55 56 59 58 57 60 61 66 67 62 63 64 68 69 70 71 72 73 74 75 65 76 77 79 78 80 81 82 wear strip seal cross-section view 83 84 85 86 87 88 89 90 54 70 91.

  • Page 27

    27 valve parts list key no. Part no. Description 50 7338111 screw, #6-19 x 3.5 cm (2 req.) 51 7281291 motor 52 7337474 motor mount 53 7284964 cam & gear 54 7030713 switch – 7331185 drain hose adaptor kit (includes key nos. 55-59) 55 á clip, drain 56 á drain hose adaptor 57 á hose clamp 58 á o-ring, ...