FCI FLT93B Installation, operation & maintenance manual

Manual is about: FLT93 Series FlexSwitch Flow, Level, Temperature Switch/ Monitor

Summary of FLT93B

  • Page 1

    Flt ® 93 series flexswitch ™ flow, level, temperature switch / monitor models: flt93b, flt93c, flt93f, flt93l, flt93s installation, operation & maintenance manual installation, betrieb und wartungshandbuch manual de instalación, operación y mantenimiento 安装、操作和维护手册 fluid components international llc...

  • Page 2

    Flt ® series flexswitch tm fluid components international llc notice of proprietary rights this document contains confidential technical data, including trade secrets and proprietary information which is the property of fluid components international llc (fci). Disclosure of this data to you is expr...

  • Page 3

    Flt ® series flexswitch tm 06en003401 rev. C fluid components international llc iii table of contents 1 general................................................................................................................................................................................................

  • Page 4

    06en003401 rev. C flt ® series flexswitch tm iv fluid components international llc liquid flow applications .............................................................................................................................................................................................23 ...

  • Page 5

    Flt ® series flexswitch tm 06en003401 rev. C fluid components international llc v appendix a drawings .........................................................................................................................................................................45 appendix b glossary .........

  • Page 6

    06en003401 rev. C flt ® series flexswitch tm vi fluid components international llc intentionally left blank.

  • Page 7

    Flt ® series flexswitch tm general fluid components international llc 1 1 general description the flt series models are multipurpose measurement instruments. The models included in this manual are flt93b (basic), flt93c (sanitary), flt93f (fast response), flt93l (in-line) and flt93s (heavy duty). Ea...

  • Page 8

    General flt ® series flexswitch tm 2 fluid components international llc application flow rate and/or level/interface and temperature sensing in liquid, gas and slurry applications. Sensing element process connection model b standard: 3/4” male npt. Models s and f standard: 3/4” male npt. Optional: 1...

  • Page 9

    Flt ® series flexswitch tm general fluid components international llc 3 the above typical service power selections are for reference only. De- pending on application requirements, surface temperature rating require- ments, and rangeability expectations, alternate power selections may be recommended....

  • Page 10

    General flt ® series flexswitch tm 4 fluid components international llc intentionally left blank.

  • Page 11

    Flt ® series flexswitch tm installation fluid components international llc 5 2 installation receiving/inspection • unpack carefully. • verify that all items in the packing list are received and are correct. • inspect all instruments for damage or contaminants prior to installation. If the above thre...

  • Page 12

    Installation flt ® series flexswitch tm 6 fluid components international llc figure 2-1 npt pipe thread mount figure 2-2 flange mount install the sensing element male npt mounting when mounting the sensing element to the process pipe, it is important that a lubricant/sealant be applied to the male t...

  • Page 13

    Flt ® series flexswitch tm installation fluid components international llc 7 packing gland assembly for applications involving the use of a packing gland (low or medium pressure) refer to the drawings in appendix a for additional detail. 1. Threaded or flanged packing gland mounts are available. The...

  • Page 14

    Installation flt ® series flexswitch tm 8 fluid components international llc sanitary assembly (flt93c) the instrument is inserted into the process connection with removable clamp fittings. The removable clamp (rc) sanitary assembly contains a removable clamp connection to the flow element. The clea...

  • Page 15

    Flt ® series flexswitch tm installation fluid components international llc 9 figure 2-5 removing ground wire securing hardware from enclosure cable and conduit entry devices the cable and conduit entry devices and blanking elements shall be of a certified flameproof type ex db and ex tb suitable for...

  • Page 16

    Installation flt ® series flexswitch tm 10 fluid components international llc 3. Place center of ring lug barrel in appropriate crimping tool chamber. Squeeze tool handles together with just enough force to hold barrel in place (do not deform barrel). 4. Insert stripped end of ground wire into barre...

  • Page 17

    Flt ® series flexswitch tm installation fluid components international llc 11 figure 2-8 local wiring diagram wiring the local enclosure configuration warning: ensure that all power is off before wiring any circuit. This procedure is for instruments with the control circuit located in the sensing el...

  • Page 18

    Installation flt ® series flexswitch tm 12 fluid components international llc wiring the remote enclosure configuration this procedure is for instruments with the control circuit located remotely (remote housing) from the sensing element (local enclosure). Locate the remote hardware location warning...

  • Page 19

    Flt ® series flexswitch tm installation fluid components international llc 13 wiring output signal terminals the primary outputs on the flt are the relays. Voltage ouputs relative to flow/level and temperature are provided on the terminal board at tb3. The signal voltage at positions 1 and 2 represe...

  • Page 20

    Installation flt ® series flexswitch tm 14 fluid components international llc figure 2-7 power jumper diagram.

  • Page 21

    Flt ® series flexswitch tm installation fluid components international llc 15 figure 2-8 120 vac input power wiring diagram figure 2-9 230 vac input power wiring diagram.

  • Page 22

    Installation flt ® series flexswitch tm 16 fluid components international llc figure 2-13 24 vac/vdc input power wiring diagram figures 2-11, 2-12 and 2-13 can be cross referenced in appendix a with fci drawings 022580 [wiring diagram flt93/5208 integral control circuit] and 022581 [wiring diagram f...

  • Page 23

    Flt ® series flexswitch tm operation fluid components international llc 17 3 operation caution: the control circuit contains electrostatic discharge (esd) sensitive devices. Use standard esd precautions when handling the control circuit. See section 2, operation, for esd details. Factory default jum...

  • Page 24

    Operation flt ® series flexswitch tm 18 fluid components international llc alarm setpoint adjustments numerical adjustment versus adjustment by observation an alarm setpoint is established using either numerical adjustment or adjustment by observation. The adjustment by observation requires the cust...

  • Page 25

    Flt ® series flexswitch tm operation fluid components international llc 19 jumper j32 j12 j13 j14 j33 flt93s/flt93b element wattage (110-ohm heater) 3 watts 1.75 watts 0.75 watts* 0.21 watts off flt93f element wattage (560-ohm heater) 0.57 watts 0.52 watts 0.49 watts 0.25 watts* off *j13 is standard...

  • Page 26

    Operation flt ® series flexswitch tm 20 fluid components international llc figure 3-2 5208 control circuit component locations 9. Follow either the detecting decreasing flow or the detecting increasing flow procedure for each flow application alarm. Detecting decreasing flow (low flow alarm) 1. Stop...

  • Page 27

    Flt ® series flexswitch tm operation fluid components international llc 21 detecting increasing flow (high flow alarm) 1. Establish the excessive process flow condition and allow the signal to stabilize. 2. Record the high flow signal. Observe that the high flow signal is less than the normal flow s...

  • Page 28

    Operation flt ® series flexswitch tm 22 fluid components international llc 6. Disconnect the voltmeter from p1. 7. Replace the enclosure cover. Note: the alarm can be set for a specific flow rate. Follow the air/gas flow applications procedure up to step 7 except establish the specific flow rate rat...

  • Page 29

    Flt ® series flexswitch tm operation fluid components international llc 23 11. Determine the setpoint by calculating the average of the wet and dry output signals; e.G., if the wet signal is 0.200 volts and the dry signal is 4.000 volts, then the calculated setpoint would be 2.100 volts. 12. Record ...

  • Page 30

    Operation flt ® series flexswitch tm 24 fluid components international llc note: the output signal at connector p1 varies inversely with changes in the process flow rate. The output signal level is also rela- tive to the type of process media being measured. See figure 3-3. 7. Establish the normal p...

  • Page 31

    Flt ® series flexswitch tm operation fluid components international llc 25 for the appropriate alarm, determine whether the status led is on or off (red for no. 1 or green for no. 2). If the led is on, turn the setpoint adjustment potentiometer (r26 for alarm no. 1 or r25 for alarm no. 2) slowly cou...

  • Page 32

    Operation flt ® series flexswitch tm 26 fluid components international llc level applications 1. Ensure that the instrument has been properly installed in the vessel. 2. Apply power to the instrument. Allow fifteen minutes for the sensing element to stabilize. 3. Remove the enclosure cover to access...

  • Page 33

    Flt ® series flexswitch tm operation fluid components international llc 27 detecting increasing temperature (high temperature alarm) 1. Move the mode switch to the cal position. 2. Adjust the calibrate potentiometer (r24) until the voltmeter equals the desired temperature signal as indicated in tabl...

  • Page 34

    Operation flt ® series flexswitch tm 28 fluid components international llc converting temp out voltage to temp in degrees f or degrees c this formula is useful when monitoring the temperature output voltage with a data acquisition system where the formula can be used in the program. Use the followin...

  • Page 35

    Flt ® series flexswitch tm operation fluid components international llc 29 0.00385 ohms/ohms/ºc 1000 ohm platinum sensors temperature versus voltage output, flt93 temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c 1.400 -104 -76 1.600 -59 -51 1.80...

  • Page 36

    Operation flt ® series flexswitch tm 30 fluid components international llc 0.00385 ohms/ohms/ºc 1000 ohm platinum sensors temperature versus voltage output, flt93 temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c 2.200 78 26 2.400 125 52 2.600 17...

  • Page 37

    Flt ® series flexswitch tm operation fluid components international llc 31 0.00385 ohms/ohms/ºc 1000 ohm platinum sensors temperature versus voltage output, flt93 temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c 3.000 267 130 3.200 315 157 3.400...

  • Page 38

    Operation flt ® series flexswitch tm 32 fluid components international llc 0.00385 ohms/ohms/ºc 1000 ohm platinum sensors temperature versus voltage output, flt93 temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c 3.800 462 239 4.000 511 266 4.200...

  • Page 39

    Flt ® series flexswitch tm operation fluid components international llc 33 0.00385 ohms/ohms/ºc 1000 ohm platinum sensors temperature versus voltage output, flt93 temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c temp output voltage °f °c 4.600 663 350 4.800 714 379 5.000...

  • Page 40

    Operation flt ® series flexswitch tm 34 fluid components international llc fail-safe alarm setting these procedures set the second relay to detect component failure (fail-safe). Low flow alarm settings install the following jumpers for the low flow fail-safe setup: j18, j20, j23, j24, j27. The follo...

  • Page 41

    Flt ® series flexswitch tm operation fluid components international llc 35 low level alarm settings (sensing element normally wet) install the following jumpers for the low level fail-safe setup: j18, j20, j23, j24, j27. The following information is assumed: relay is de-energized in the alarm condit...

  • Page 42

    Operation flt ® series flexswitch tm 36 fluid components international llc intentionally left blank.

  • Page 43

    Flt ® series flexswitch tm maintenance fluid components international llc 37 4 maintenance warning: to avoid hazards to personnel, ensure that all environmental isolation seals are properly maintained. Caution: the insturment contains electrostatic discharge (esd) sensitive devices. Use standard esd...

  • Page 44

    Maintenance flt ® series flexswitch tm 38 fluid components international llc intentionally left blank.

  • Page 45

    Flt ® series flexswitch tm troubleshooting fluid components international llc 39 5 troubleshooting warning: only qualified personnel should attempt to test this instrument. The operator assumes all responsibilities for safe practices while troubleshooting. Caution: the control circuit contains elect...

  • Page 46

    Troubleshooting flt ® series flexswitch tm 40 fluid components international llc troubleshooting the flow element use tables 5-1 and 5-2 to determine if the flow element is wired correctly or has failed. Turn off the input power to the instrument. Unplug the control circuit from its socket and measu...

  • Page 47

    Flt ® series flexswitch tm troubleshooting fluid components international llc 41 figure 5-1 terminal board, test points.

  • Page 48

    Troubleshooting flt ® series flexswitch tm 42 fluid components international llc troubleshooting the control circuit 1 is the yellow power indicator led: dim, off or blinking yellow led dim or off with the power applied, measure the 9-volt reference voltage at p1, pins 2 (blue) to 4 (black). See fig...

  • Page 49

    Flt ® series flexswitch tm troubleshooting fluid components international llc 43 4 signal voltage observation with the power applied, note the position of the heater wattage control jumper plug and remove it. Place the jumper plug temporally on position j33. With a voltmeter measure the voltage at p...

  • Page 50

    Troubleshooting flt ® series flexswitch tm 44 fluid components international llc intentionally left blank.

  • Page 51

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 45 appendix a drawings 3/4” npt with local hazardous location type 4x enclosure.

  • Page 52

    Appendix a - drawings flt ® series flexswitch tm 46 fluid components international llc 3/4” npt with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 53

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 47 1” npt with local hazardous location type 4x enclosure.

  • Page 54

    Appendix a - drawings flt ® series flexswitch tm 48 fluid components international llc 1” npt with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 55

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 49 flanged with local hazardous location type 4x enclosure.

  • Page 56

    Appendix a - drawings flt ® series flexswitch tm 50 fluid components international llc flanged with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 57

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 51 1-1/4” npt low pressure packing gland with local hazardous location type 4x enclosure.

  • Page 58

    Appendix a - drawings flt ® series flexswitch tm 52 fluid components international llc 1-1/4” npt low pressure packing gland with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 59

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 53 flanged low pressure packing gland with local hazardous location type 4x enclosure.

  • Page 60

    Appendix a - drawings flt ® series flexswitch tm 54 fluid components international llc flanged low pressure packing gland with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 61

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 55 1-1/4” npt, medium pressure packing gland with local hazardous location type 4x enclosure.

  • Page 62

    Appendix a - drawings flt ® series flexswitch tm 56 fluid components international llc 1-1/4” npt, medium pressure packing gland with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 63

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 57 flanged, medium pressure packing gland with local hazardous location type 4x enclosure.

  • Page 64

    Appendix a - drawings flt ® series flexswitch tm 58 fluid components international llc flanged, medium pressure packing gland with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 65

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 59 3/4” mnpt compression fitting with local hazardous location type 4x enclosure.

  • Page 66

    Appendix a - drawings flt ® series flexswitch tm 60 fluid components international llc 3/4” mnpt compression fitting with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 67

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 61 flanged compression fitting with local hazardous location type 4x enclosure.

  • Page 68

    Appendix a - drawings flt ® series flexswitch tm 62 fluid components international llc flanged compression fitting with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 69

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 63 flt93f style head : 1/4” npt with local hazardous location type 4x enclosure.

  • Page 70

    Appendix a - drawings flt ® series flexswitch tm 64 fluid components international llc flt93f style head: 1/4” npt with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 71

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 65 flt93l: 3/4” npt with local hazardous location type 4x enclosure.

  • Page 72

    Appendix a - drawings flt ® series flexswitch tm 66 fluid components international llc flt93l: 3/4” npt with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 73

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 67 flt93l: 1” npt with local hazardous location type 4x enclosure.

  • Page 74

    Appendix a - drawings flt ® series flexswitch tm 68 fluid components international llc flt93l: 1” npt with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 75

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 69 flt93l: flanged with local hazardous location type 4x enclosure.

  • Page 76

    Appendix a - drawings flt ® series flexswitch tm 70 fluid components international llc flt93l: flanged with local hazardous location type 4x enclosure: 3-port remote type 4x.

  • Page 77

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 71 flt93c : sanitary flange with local hazardous location type 4x enclosure.

  • Page 78

    Appendix a - drawings flt ® series flexswitch tm 72 fluid components international llc flt93 surface mount: local wiring diagram.

  • Page 79

    Flt ® series flexswitch tm appendix a - drawings fluid components international llc 73 flt93 surface mount : remote wiring diagram.

  • Page 80

    Appendix a - drawings flt ® series flexswitch tm 74 fluid components international llc flt93 pwb module: 5208.

  • Page 81

    Flt ® series flexswitch tm appendix b - glossary fluid components international llc 75 appendix b glossary abbreviations delta-r (dr) differential resistance delta-t (dt) differential temperature dmm digital multimeter dpdt double pole double throw fci fluid components intl htr heater led light emit...

  • Page 82

    Appendix b - glossary flt ® series flexswitch tm 76 fluid components international llc intentionally left blank.

  • Page 83

    Flt ® series flexswitch tm appendix c - approval information fluid components international llc 77 appendix c approval information ec information.

  • Page 84

    Appendix c - approval information flt ® series flexswitch tm 78 fluid components international llc intentionally left blank.

  • Page 85

    Flt ® series flexswitch tm appendix c - approval information fluid components international llc 79 safety instructions for the use of the flt93 flowswitch in hazardous areas approval kema 02atex2166 x and approval iec certificate iecex dek14.0080x for: integral version: ii 2 g ex db iic t4…t2 gb ii ...

  • Page 86

    Appendix c - approval information flt ® series flexswitch tm 80 fluid components international llc gb irl english- safety instructions these safety instructions are valid for the fluid components, flt93 flowswitch to the ec type approval certificate no. Kema 02 atex 2166 (certificate number on the t...

  • Page 87

    Flt ® series flexswitch tm appendix c - approval information fluid components international llc 81 f b l consignes de sécurité ces consignes de sécurité sont valables pour le modèle flt93 flowswitch de la société fluid components (fci) conforme au certificat d’épreuves de type kema 02 atex 2166 (num...

  • Page 88

    Appendix c - approval information flt ® series flexswitch tm 82 fluid components international llc p português - normas de segurança estas normas de segurança são válidas para os fluid components, flt93 flowswitch conforme o certificado de teste de modelo n.º kema 02 atex 2166 (número do certificado...

  • Page 89

    Flt ® series flexswitch tm appendix c - approval information fluid components international llc 83 annex 1 annex 1 to certificate of conformity iecex dek 14.0080x, issue 0 annex 1 to iecex tr nl/dek/extr14.0088/00 annex 1 to eu type examination certificate kema 02atex2166 x, issue 4 page 1 of 5 form...

  • Page 90

    Appendix c - approval information flt ® series flexswitch tm 84 fluid components international llc annex 1 to certificate of conformity iecex dek 14.0080x, issue 0 annex 1 to iecex tr nl/dek/extr14.0088/00 annex 1 to eu type examination certificate kema 02atex2166 x, issue 4 page 2 of 5 pos. Explana...

  • Page 91

    Flt ® series flexswitch tm appendix c - approval information fluid components international llc 85 annex 1 to certificate of conformity iecex dek 14.0080x, issue 0 annex 1 to iecex tr nl/dek/extr14.0088/00 annex 1 to eu type examination certificate kema 02atex2166 x, issue 4 page 3 of 5 model decodi...

  • Page 92

    Appendix c - approval information flt ® series flexswitch tm 86 fluid components international llc annex 1 to certificate of conformity iecex dek 14.0080x, issue 0 annex 1 to iecex tr nl/dek/extr14.0088/00 annex 1 to eu type examination certificate kema 02atex2166 x, issue 4 page 4 of 5 thermal data...

  • Page 93

    Flt ® series flexswitch tm appendix c - approval information fluid components international llc 87 annex 1 to certificate of conformity iecex dek 14.0080x, issue 0 annex 1 to iecex tr nl/dek/extr14.0088/00 annex 1 to eu type examination certificate kema 02atex2166 x, issue 4 page 5 of 5 pigtail vers...

  • Page 94

    Appendix c - approval information flt ® series flexswitch tm 88 fluid components international llc intentionally left blank.

  • Page 95

    Flt ® series flexswitch tm appendix c - approval information fluid components international llc 89 sil information.

  • Page 96

    Appendix c - approval information flt ® series flexswitch tm 90 fluid components international llc intentionally left blank.

  • Page 97

    Flt ® series flexswitch tm appendix d - temp comp fluid components international llc 91 appendix d temperature compensation introduction temperature compensation (temp comp) is an essential part of the flt flexswitch circuitry. When the temp comp is set correctly, the instru- ment stays accurate ove...

  • Page 98

    Appendix d - temp comp flt ® series flexswitch tm 92 fluid components international llc balance procedure the following steps are the flow element balance procedure required to complete the temp comp restoration and must be used when install- ing remote units with more than 10 feet of cable. 1. Conn...

  • Page 99

    Flt ® series flexswitch tm appendix d - temp comp fluid components international llc 93 power supply settings flt93s 3 watts 1.75 watts 0.75 watts 0.21 watts set for 18.0 vdc set for 13.8 vdc set for 9.0 vdc set for 4.9 vdc flt93f 0.57 watts 0.52 watts 0.49 watts 0.25 watts set for 18.0 vdc set for ...

  • Page 100

    Appendix d - temp comp flt ® series flexswitch tm 94 fluid components international llc temp comp r5 r8 factor k ohms k ohms 0.042 119.75 263.16 0.041 119.88 256.41 0.04 120.00 250.00 0.039 120.13 243.9 0.038 120.25 238.10 0.037 120.38 232.56 0.036 120.5 227.27 0.035 120.63 222.22 0.034 120.75 217.3...

  • Page 101

    Flt ® series flexswitch tm appendix e - customer service fluid components international llc 95 appendix e customer service customer service/technical support fci provides full in-house technical support. Additional technical representation is also provided by fci field representatives. Before contac...

  • Page 102

    Appendix e - customer service flt ® series flexswitch tm 96 fluid components international llc non-warranty repairs or returns fci returns repaired equipment to the customer either collect or prepaid and adds freight charges to the customer invoice. Extended warranty an extended warranty is availabl...

  • Page 103

    Flt ® series flexswitch tm appendix e - customer service fluid components international llc 97.

  • Page 104

    Appendix e - customer service flt ® series flexswitch tm 98 fluid components international llc.

  • Page 105

    Flt ® series flexswitch tm appendix e - customer service fluid components international llc 99 warranties goods furnished by the seller are to be within the limits and of the sizes published by the seller and subject to the seller’s standard tolerances for variations. All items made by the seller ar...

  • Page 106

    Flt ® series flexswitch tm fluid components international llc 06en003401 rev. C fci’s complete customer commitment. Worldwide iso 9001 and as9100 certified notice of proprietary rights this document contains confidential technical data, including trade secrets and proprietary information which is th...