FOXSECUR Thinline Series User Manual
USER’S MANUAL
Thinline Series Icon Keypads
TM
.com
Icon Display
Select keys
COMMAND Key
Back Arrow Key
Shortcut & Digit Keys
S
S
S
Resetting Sensor
Use this function to reset the smoke detectors after an alarm has occurred. Press and hold
the RESET (2) key for two seconds. The Flame icon will clear from the display when the
Sensor Reset operation is complete and the smoke detectors are reset.
User Codes
+ [your code] + [user number] + [user code] + [level]
This function allows you to Add or Delete user codes. Each user is assigned 3 settings:
User Number:
how the system identifies a user
User Code:
the four digit number a user enters into the keypad to arm, disarm or to
perform other system operations.
User Level:
the user is also assigned a level of authority (Master, Standard,
Limited or Scheduled) to determine the functions the user can access. See below for User
Code authority levels.
Press and hold CODE key (4) until the keypad beeps once, enter your user code.
Enter the user number # (02-15) to add or delete
XRSuper6 = 02-15
XR40 = 02-63
XT30 = 02-30
XT50 = 02-99
Enter four-digit user code to assign to the user number or 0000 to delete an
existing user.
Enter the authority level (1-4)
Level 1: Scheduled User
(XR40 only)
The Scheduled authority level performs all the system functions of the Limited level
during a valid schedule with the exception of turning Outputs on or off and System Test.
Disarming is allowed outside of a schedule, but an Unauthorized Entry message is sent to
your monitoring station.
Level 2:
Limited User
(XR40 only)
The Limited authority level can perform all the system funcitons of the Standard Level
during a valid schedule with the excepton of turning Outputs on or off and System Test.
Disarming is allowed outside of a schedule, but an Unauthorized Entry message is sent to
your monitoring station.
Level 3: Standard User
(XRS6/XR20/XR40)
The Standard authority level can perform all system functions except adding or deleting
user codes.
Level 4: Master User
(XRS6/XR20/XR40)
The Master authority level can perform all system functions.
Zone Status
Use this function to display burglary protection zones that are faulted while the system is
disarmed. Any faulted burglary zones are shown in the 3-character display allowing you
to correct the problem before arming.
ZONE
9
CODE
4
RESET
2
SYSTEM FUNCTIONS
/continued
SYSTEM TEST
System Test is used to test the battery, alarm belt or siren, and monitoring station
communication. Press and hold the TEST ( ) key for two seconds. The System Test
function begins automatically as soon as you select it.
Test in Progress (tSt)
The system is currently being tested by an installation or service technician.
The bell sounds for two seconds and then the communication test begins.
Transmit Good (tgd)
The communication portion to the system test was successful.
Transmit Failed (tFL)
The communication portion of the system test failed to communicate to the
Central Monitoring Station.
SYSTEM DISPLAYS ( 3-character )
(A) Armed
The system is armed ALL or AWAY
(Abt) Alarm not sent
The alarm signal was aborted and not sent to the central station because
a user code was entered to disarm the system or CANCEL was selected.
(ALC) Alarm not cancelled
An alarm signal has just been sent to the central station and cancelled
because a user code was entered after the alarm was sent or CANCEL was
selected.
(H) Home
The system is armed HOME.
(P) Perimeter
The system is armed Perimeter (PERIM).
(S) Sleep
The system is armed SLEEP.
(bSY) System busy
The system is performing other functions at this time.
(rFA) Wireless jammed alarm / (rFJ) Trouble
Your system may be programmed for wireless interference detection and, if
displayed, your wireless receiver has detected an interferring signal.
(rFt) Wireless trouble
Your wireless receiver is unplugged or not operating properly.
TEST
SIMPLE TO USE
The easy-to-understand icons, combined with a three-character
display, provides visual feedback enabling simple arming, disarming,
and a variety of other functions.
CODELESS ARMING & DISARMING
The innovative 7363 Thinline Icon Keypad contains a built-in DMP
proximity reader that allows you to simply present a proximity
credential to the keypad to arm or disarm the system without the need
to remember a user code.
USER-FRIENDLY SHORTCUT KEYS
Twelve one-button shortcut keys simplify operation providing access
to a variety of functions. For example, pressing the HOME key for two
seconds arms your system when you’re at home for the evening. The
keys enable users to quickly arm, monitor zones, easy exit, test or reset
the system and a variety of other functions.
PLEASE TAKE A MOMENT
To learn the range of features of your system, please read through this
user’s guide thoroughly. All icons and keypad operations are
completely described.