Franco Belges Le Continental 174 07 53 Technical Manual

Manual is about: Oil fired

Summary of Le Continental 174 07 53

  • Page 1

    Technical manual to be saved by the user for future reference document n° 952-3 en ~ 02/03/2000 les fonderies franco-belges 59660 merville phone : 03.28.43.43.43 fax : 03.28.43.43.99 rc hazebrouck 445750565b subject to modifications le continental oil fired stove model 174 07 53 (ansi/ul & can/csa a...

  • Page 2

    Description of the unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 description . . . . . . . . . . . . . . . . . . . 3 optional equipment . . . . . . . . . . . . . . 3 specifications . . . . . . . . . . . . . . . . . 3 operating principle . . . . . . . . . . . ...

  • Page 3

    1. Description of the unit 1.1. Description flued oil stove with vaporizing burner (norm en1) 1.2. Optional equipment ¤ ground vat 1.3. Specifications nominal heat output (nf d 35.001) . . . Kw 6,5 . . . . . . . . . . . . . . . . . . . . . . Btu/hr 26.000 oil consumption at : - maximum speed . . . ....

  • Page 4

    1.4. Operating principle furnace oil is fed to the burner floor (fig. 1) where is it ignited by means of a firestarter. The heat produced by this flame brings the burner temperature to the required level to vaporize the fuel. Oil will only burn as a vapour not a liquid. Room combustion air enters th...

  • Page 5

    2.5. Pre-utilisation check check, that the seals are in good condition, that the door closes correctly, that the glasses are not damaged. 2.6. Mounting the levelling feet fit the 3 screws and the 3 caps supplied (on the burner) into each leg of the stove (fig. 4). 2.7. Levelling it is essential to e...

  • Page 6

    2.9. Oil flow adjustment the float regulator has been adjusted at the factory and should not need further adjustment. If the burner does not work correctly, check possible causes before readjusting the settings : - chimney draught - fresh air inlet - oil supply. Low setting (refer to fig. 7 , # 2) :...

  • Page 7: 3. Operating Instructions

    3. Operating instructions 3.1. Fuel warning : your stove is fitted with a specific float regulator for a specific oil. ¤ fuel oil # 2 or fuel oil # 1 the fuel oil must be free from any dirt and water which could disturb the stove in operation. 3.2. Lighting procedure - be sure the control knob is to...

  • Page 8

    Regulator filter opening in order to collect the oil contained in the regulator, - remove the filter cover plate located under the regulator (# 4 of fig. 8) with a screwdriver, - remove the tubular filter from the regulator. Clean, if ne it with oil using a soft brush, never a wire-brush, - replace ...

  • Page 9: 4. Spare Parts

    4. Spare parts when ordering spare parts, please indicate : model n°, colour code, description of the part, code of the part. Example : oil fired stove 174 07 53 l, leg 300120 77 a = 174 07 53 l b = 174 07 53 y c = 174 07 53 j 1 100917 cam pin . . . . . . . . . 12x20 m7 . . . . . . . A . . . . . . B...

  • Page 10

    67 188784 refractory glass . . . . . 27x(112x20) . . . . . . A . . . . . . B . . . . . . C . . . . . . 01 67 199304 mirror glass (optional) . . 1x(112x20) . . . . . . A . . . . . . B . . . . . . C . . . . . . 27 68 242913 ground vat (optional) . . . . . . . . . . . . . . . A . . . . . . B . . . . . ...

  • Page 11

    Fig. 9 document n° 952-3 en ~ 02/03/2000 continental poêle à combustible liquide notice de référence 11.

  • Page 12

    § warranty certificate § § legal warranty our products are guaranteed for twelve months against any defect, flaw or imperfection. During this time, all parts judged defective by our warranty control department may be repla- ced in our workshops. Incidental costs of transportation and packing payable...