Hague Quality Water 700MM Installation And Service Manual

Manual is about: Maximizer Water Softener

Summary of 700MM

  • Page 1

    I n s t a l l a t i o n a n d s e r v i c e m a n u a l 4343 s. Hamilton road, groveport, ohio 43125 version 1 model 700mm water softener.

  • Page 2

    Notes ............................................................................................................................ 1 getting maximum efficiency from your appliance ..................................... 2 checklist before installation......................................................

  • Page 3

    Date of installation: __________________________________ model number: _____________________________________ serial number: ______________________________________ returned limited warranty card date: ___________________ 1 notes.

  • Page 4

    How to get the maximum efficiency from your appliance 1. Fill salt cabinet when water level is above salt level. Do not mix different types of salt. If iron is present in your water, use a salt with an iron-cleaning additive to help keep resin clean. You may also use a resin cleaner on a monthly bas...

  • Page 5

    3 checklist before installation 1. Water pressure - not less than 20 psi constant for softeners. 2. Double check hardness - of water with test strips provided to verify that your appliance is right for the job. Model 700mm for up to 70 grains hardness per gallon. 3. Water supply flow rate - 5 gallon...

  • Page 6

    4 do’s and don’ts some do's 1. Do comply with all local plumbing and electrical codes. 2. Do install pressure-reducing valve if inlet pressure exceeds 90 psi. 3. Do install gravity drain on salt storage cabinet. See figure 7. 4. Do secure drain line on appliance and at drain outlet. See figure 3. 5....

  • Page 7

    Use this diagram as a location and installation guide for your model 700mm , water conditioner. This diagram applies to all types of installations (i.E. Basement, slab, crawl space, outside). Bypass valves. To simplify installation and servicing, a one-piece or a three way bypass valve appliance is ...

  • Page 8

    6 reference illustrations caution! The drain line must not be kinked, crimped or restricted in any way. The drain line should be a minimum 1/2" inside diameter and cannot be reduced in size. Figure 2 plumbing connections figure 3 connecting drain line installation tip for hard plumbing the appliance...

  • Page 9

    7 reference illustrations figure 4 - bypass valve figure 5 - in bypass position for service or bypass. Optional bypass valve part #93884 may be available through your local hardware store, plumber or call our helpline 1-800-437-8993 from 8 am to 5 pm est. To order. Note: do not plumb bypass valve in...

  • Page 10

    Figure 8 8 reference illustrations plugging in transformer do not plug transformer into an outlet that is controlled by on/off switch. Figure 7 overflow connection (1/2” i.D.).

  • Page 11

    9 reference illustrations figure 10 adding salt to the brine cabinet 2 gallons water figure 9.

  • Page 12

    10 cycles water by-passes your appliance during regeneration to allow iron, sediment, hardness, etc. To be washed down the drain. After regeneration, the appliance returns to service, providing your home with treated water. Regeneration cycles: 1. First up-flow backwash. A rapid up-flow of water flu...

  • Page 13

    11 installation and start-up procedures each water conditioning appliance includes water test strips and 8' of drain line. Caution: be sure the controller is firmly “locked” onto the drive end cap assembly. The four tabs on top of the drive end cap will allow the clips on the bottom of the controlle...

  • Page 14

    12 installation and start-up procedures 8. Setting number. For model 700mm determine your controller setting number. Do not guess at the setting; continued water quality problems or damage to the appliance could result. Follow the instructions on the ph and hardness test strips provided with your ap...

  • Page 15

    Setting the 4 button controller 13 demand regeneration you won't have to worry about vacation settings or extra guests because the controller measures water usage and regenerates based on need. The appliance will regenerate using only the neces- sary amount of water and salt. If power has been turne...

  • Page 16

    14 setting the controller - continued advanced customer settings: your appliance can be programmed for high capacity (hc) or high efficiency (he). High capacity means the appliance will regenerate less often, but use more salt. High efficiency will make the appliance regenerate more often and use le...

  • Page 17

    15 setting the controller - continued 7. "set time" and "12" is now lit. To set the time, press and hold the change button to advance the numerical display, and switch from "pm" to "am" if appropriate. Note: set the time to the nearest hour. Pressing and releasing the set button will save the time d...

  • Page 18

    16 care, maintenance and parts part# description quantity 1 54306 salt port lid 1 2 54324 valve cover assembly 1 3 54540-700 computer control assembly 1 4 93245 12v transformer/power cord 1 5 54303 cabinet 1 6 54305 support panel 1 7 93530 media tank, empty, 700 only 1 figure 11.

  • Page 19

    17 care, maintenance and parts figure 12 - cabinet and assemblies part# description quantity 1 co700a cabinet overflow 1 2 54510 i/o adapte assembly 1 3 93838 o-ring 2 4 93808 o-ring 2 5 54520 drive end cap c 1 6 93870 screw 4 7 90828 o-ring 1 8 93501 injector assembly 1 9 93835 sleeve 2 10 90614-2....

  • Page 20

    18 care, maintenance and parts figure 13 - injector assembly part# description quantity 1 93810 injector screen 1 2 93223 injector throat 1 3 93220 injector seal 1 4 93221 injector nozzle 1 5 93232 top injector seal (thin) 1 6 93222 injector cap 1 7 90807 screw 4 93501 includes all of the above..

  • Page 21

    Care, maintenance and parts figure 14 - i/o adapter assembly 19 part# description quantity 1 54313 3/4" io adapter 1 2 90232 turbine sensor cap 1 3 90809 sensor cap screw 1 4 93858 turbine sensor assembly 1 5 90522 turbine assembly 1 6 93229 flow director 1 7 93838 “o” ring 2 54510 includes all of t...

  • Page 22

    20 care, maintenance and parts figure 15 - drive end cap assembly part# description quantity 1 90802 screw 2 2 90217 drive motor 1 3 93891 1/4” hex nut 2 4 93238 drive gear 1 5 90809 screw, cam cover 2 6 93219 piston slide cam cover 1 7 93217 piston slide cam 1 8 93583 drive end cap 1 9 93216 piston...

  • Page 23

    Concave side care, maintenance and parts figure 16 - brine valve housing assembly 21 part# description quantity 1 93620 piston assembly 1 (includes o-ring & spring) 2 90821 o-ring 1 3 93260 housing 1 4 90843 .5 pm flow control 1 5 93805 o-ring 1 6 54314 brine valve cap 1 7 90807 screw 2 8 54315 elbo...

  • Page 24

    Care, maintenance and parts figure 17 - safety shutoff assembly 22 part# description quantity 1 54226 safety shutoff 1 2 54227 float 1 3 54228 air check 1.

  • Page 25

    23 care, maintenance and parts figure 18 - brine valve elbow assembly part# description quantity 1 54112 1/2” compression assembly 1 2 54138 3/8” compression assembly 1 3 201120 3/8” nylon insert 1 2 1 3.

  • Page 26

    Care, maintenance and parts figure 19 - bottom fill plug assembly 24 part# description quantity 1 90238 fill plug 1 2 90819 o-ring 2.

  • Page 27

    Maximum compensated hardness (grains) maximum ferrous iron reduction minimum ph media type and amounts *salt usage (lbs.) / capacity (he - high efficiency) *salt usage (lbs.) / capacity (hc - high capacity) minimum / maximum water and ambient temperature mineral tank size peak flow rate / psi drop (...

  • Page 28

    26 troubleshooting problem cause solution add salt (refer to "regenerate" page 13) remove air check draw tube and flush with clean water. Clean injec- tor assembly. Clean any sediment from brine cabinet. Straighten, thaw or unclog the drain line. Remove injector cap and clean noz- zle and throat wit...

  • Page 29

    27 troubleshooting problem cause solution with 12 vac present at controller, replace circuit board. Make sure computer control is pushed all the way onto drive end cap. Remove foreign objects from valve body. Repair drive end cap. Remove restriction, thaw or straight- en drain line. Clean flow contr...

  • Page 30

    28 limited warranty to whom warranty is extended this warranty is issued to the original owner at the original location site and is not transferable to other sites or to sub- sequent owners of the appliance. To place the equipment under warranty, the warranty registration card must be completed and ...

  • Page 32: Maximizer

    ©1998 maximizer ® p.O. Box 298, groveport, oh 43125 litho usa form #70061 or0504 u ® l ®.