I-Bus IBC 2606 User Manual

Manual is about: 6U-size CompactPCI Master SBC with Pentium III / Celeron processor

Summary of IBC 2606

  • Page 1

    User’s guide ibc 2606 6u-size compactpci™ master sbc with pentium® iii / celeron™ processor.

  • Page 2

    2 ibc 2606 user's guide copyright 2004 all rights reserved the information in this document is subject to change without prior notice in order to improve reliability, design, and function, and does not represent commitment on the part of the manufacturer. In no event will the manufacturer be liable ...

  • Page 3: Contents

    Ibc 2606 user's guide 3 contents 1 hardware configuration ...................................................... 6 1.1 i ntroduction .................................................................................................................................7 1.1.1 high performance pentium ® iii...

  • Page 4: Figures

    4 ibc 2606 user's guide a. Programming the watchdog timer............. 35 b. Pin assignments .......................................................... 37 b.1. Vga d isplay c onnector (cn3) ....................................................................................................38 b.2. Co...

  • Page 5: Tables

    Ibc 2606 user's guide 5 tables table 1-1: ibc 2606 jumper descriptions .......................................... Table 1-2: clear cmos......................................................................... Table 1-3 ibc 2606 connector descriptions .................................... Table 2-1: i...

  • Page 6: 1 Hardware Configuration

    6 ibc 2606 user's guide 1 hardware configuration.

  • Page 7

    Ibc 2606 user's guide 7 1.1 introduction the ibc 2606 is a 6u-size compactpci tm all-in-one single board pentium ® iii/celeron tm cpu card which complies with picmg 2.0 r2.1 compactpci tm specifications. Targeting performance- demanding applications like computer telephony and communications, the ib...

  • Page 8

    8 ibc 2606 user's guide 1.2 specifications standard sbc functions • cpu: socket 370 pentium ® iii coppermine cpu up to 850 mhz socket 370 celeron tm cpu up to 566 mhz • bios: award 2 mb flash memory • chipset: intel ® 440bx chipset • front side bus clock: 100 mhz for intel ® pentium ® iii cpu 66 mhz...

  • Page 9

    Ibc 2606 user's guide 9 agp vga interface • controller: intel c&t 69000 • agp 1.0 compliant, 66 mhz • display memory: on-chip 2 mb sdram • display resolution: resolution number of colors 640 x 480, 800 x 600, 1024 x 768, 1280 x 1024 256 (8 bits) 640 x 480, 800 x 600, 1024 x 768 65, 536 (16 bits) 640...

  • Page 10

    10 ibc 2606 user's guide 1.3 functional block diagram figure 1-1: ibc 2606 functional block diagram.

  • Page 11

    Ibc 2606 user's guide 11 1.4 jumpers 1.4.1 jumper locations the ibc 2606 provides a jumper (jp2) for configuring your board for specific applications other than the default settings. Table 1-1 lists the jumper function. Figure 1-2 illustrates the jumper location. Read this section carefully before c...

  • Page 12

    12 ibc 2606 user's guide 2. Close jumper jp2 (2-3) for about 3 seconds. 3. Close jumper jp2 (1-2). 4. Turn on the system. The bios is reset to its default setting. Table 1-2: clear cmos cmos jp2 clear normal (default.

  • Page 13

    Ibc 2606 user's guide 13 1.5 connectors on board connectors link to external devices such as hard disk drives, keyboards, or flooy drives, etc. Table 1-3 lists the function of each connector and figure 1-2 and figure 1-3 illustrate each connector location. Chapter 2 gives instructions for connecting...

  • Page 14

    14 ibc 2606 user's guide figure 1-2: ibc 2606 jumper and connector locations.

  • Page 15

    Ibc 2606 user's guide 15 figure 1-3: ibc 2606 front panel connector and indicator locations.

  • Page 16

    16 ibc 2606 user's guide 1.6 safety precautions follow these simple precautions to protect yourself from harm and the products from damage. 1. To avoid electric shock, always disconnect the power from your pc chassis before you work on it. Don't touch any components on the cpu card or other cards wh...

  • Page 17

    Ibc 2606 user's guide 17 1.7 installing sdram (sodimms) the ibc 2606 provides two 144-pin sodimm sockets. Each socket accepts either 16, 32, 64, 128 or 256 mb sdram. The sockets can be filled in any combination with sodimms of any size, giving a total memory capacity between 16 and 512 mb. If only o...

  • Page 18

    18 ibc 2606 user's guide 1.8 installing cpu and heat sink the ibc 2606 accepts intel ® socket 370 pentium ® iii cuppermine cpu or intel ® socket 370 celeron tm cpu. In order to meet critical environmental conditions and the physical space of the ibc 2606 a heat sink was used to fulfill both needs. P...

  • Page 19: 2 Connecting Peripherals

    Ibc 2606 user's guide 19 2 connecting peripherals.

  • Page 20

    20 ibc 2606 user's guide 2.1 ide device (cn10) the ibc 2606 provides two ide (integrated device electronics) channels via the j3 connector to the rear transition board (ibc 2706 for ibc 2606). Four ide drives can be connected to the ibc 2606 through the rear transition board. Users can connect two i...

  • Page 21

    Ibc 2606 user's guide 21 table 2-1: ibc 2606 serial port default settings port address default com1 3f8, 3e8 3f8/irq4 com2 2f8, 2e8 2f8/irq3 2.5 ethernet configuration (cn6 and cn7) the ibc 2606 is equipped with dual high performance 32-bit pci-bus fast ethernet interfaces which are fully compliant ...

  • Page 22

    22 ibc 2606 user's guide 6. Secure the card by pushing in the red handle to lock it into place. Figure 2-1: installing the card into the chassis to remove a card: 1. Unscrew the screws on the front panel. 2. Lift the upper handle up and press the lower handle down to release the card from the backpl...

  • Page 23

    Ibc 2606 user's guide 23 3 ethernet software configuration.

  • Page 24

    24 ibc 2606 user's guide 3.1 introduction the ibc 2606 has two on-board high-performance fast ethernet interfaces which comply with ieee 802.3/802.3u for 10base-t and 100 base-tx data rates. The module uses two intel ® 82559 fast ethernet controllers with integrated phy and is compatible with the in...

  • Page 25: 4 Agp Svga Setup

    Ibc 2606 user's guide 25 4 agp svga setup.

  • Page 26

    26 ibc 2606 user's guide the ibc 2606 uses an intel c&t 69000 chipset as its agp vga controller. The vga controller has an integrated 2 mb sdram operating at 83 mhz, and can drive crt displays with resolutions up to 1024 x 768 at 64 k colors. It supports interlaced and non-interlaced analog monitors...

  • Page 27: 5 Award Bios Setup

    Ibc 2606 user's guide 27 5 award bios setup.

  • Page 28

    28 ibc 2606 user's guide 5.1 award bios setup figure 5-1: setup program initial screen award's bios rom has a built-in setup program that allows users to modify the basic system configuration. This type of information is stored in battery-backed cmos so that it retains the setup information when the...

  • Page 29

    Ibc 2606 user's guide 29 figure 5-2: cmos setup screen 5.1.3 bios features setup the "bios features setup" screen will appear after the bios features setup item from the cmos setup utility menu was chosen. This screen allows the user to configure the ibc 2606 according to his particular requirements...

  • Page 30

    30 ibc 2606 user's guide virus warning during and after the system boots up, any attempt to write to the boot sector or partition table of the hard disk drive will halt the system. If this happens, a warning message will be displayed. You can run the anti-virus program to locate the problem. If viru...

  • Page 31

    Ibc 2606 user's guide 31 boot up system speed high sets the speed to high low sets the speed to low ide hdd block mode enabled enable ide hdd block mode. Bios will detect the block size of the hdd and send a block command automatically. Disabled disable ide hdd block mode gate a20 option normal the ...

  • Page 32

    32 ibc 2606 user's guide c8000 - cffff shadow/dc000-dffff shadow these settings determine whether optional rom will be copied to ram in blocks of 16 kb. Enabled optional shadow is enabled disabled optional shadow is disabled 5.1.4 chipset features setup choosing the "chipset features setup" option f...

  • Page 33

    Ibc 2606 user's guide 33 power management this option allows you to determine if the values in power management are disabled, user- defined, or predefined. Hdd power management you can choose to turn the hdd off after one of the time intervals listed, or when the system is in suspend mode. If in a p...

  • Page 34

    34 ibc 2606 user's guide 5.1.8 load setup defaults "load setup defaults" loads the values required by the system for maximum performance. 5.1.9 password setting to change, confirm, or disable the password, choose the "password setting" option form the setup main menu and press [enter]. The password ...

  • Page 35

    Ibc 2606 user's guide 35 a. Programming the watchdog timer.

  • Page 36

    36 ibc 2606 user's guide to program the watchdog timer, you must write a program which writes a value to i/o port address 443 (hex). This output value represents time interval. The value range is from 01 (hex) to 3f (hex), and the related time interval is 1 sec. To 63 sec. Data time interval 01 1 se...

  • Page 37: Pin Assignments

    Ibc 2606 user's guide 37 b. Pin assignments.

  • Page 38

    38 ibc 2606 user's guide b.1. Vga display connector (cn3) table b-1: ibc 2606 crt display connector pin signal pin signal 1 red 9 vcc 2 green 10 gnd 3 blue 11 n/c 4 n/c 12 sda 5 gnd 13 hsync 6 gnd 14 vsync 7 gnd 15 scl 8 gnd b.2. Com1 and com2 serial ports (cn1 and cn2) table b-2: ibc 2606 com1 and ...

  • Page 39

    Ibc 2606 user's guide 39 b.3. Keyboard and mouse connector (cn5) table b-3: ibc 2606 keyboard connector pin signal 1 kdat 2 mdat 3 gnd 4 vcc 5 kclk 6 mclk b.4. Usb connector (cn4) table b-4: usb connector pin usb signal 1 vcc 2 usbd0- 3 usbd0+ 4 gnd b.5. Cpu fan power connector (cn8) table b-5: ibc ...

  • Page 40

    40 ibc 2606 user's guide b.6. Ethernet rj-45 connectors (cn6 and cn7) table b-6: ibc 2606 ethernet rj-45 connectors pin signal 1 tx+ 2 tx- 3 rx+ 4 n/c 5 n/c 6 rx- 7 n/c 8 n/c.

  • Page 41

    Ibc 2606 user's guide 41 b.7. Compactflash socket (cn9) table b-7: ibc 2606 compactflash socket pin signal pin signal 1 gnd 26 n/c 2 id3 27 id11 3 id4 28 id12 4 id5 29 id13 5 id6 30 id14 6 id7 31 id15 7 hcs1- 32 hcs3- 8 gnd 33 n/c 9 gnd 34 hior- 10 gnd 35 hiow- 11 gnd 36 n/c 12 gnd 37 hirq 13 vcc 38...

  • Page 42

    42 ibc 2606 user's guide b.8. System i/o ports table b-8: system i/o ports addr. Range (hex) device 000-01f dma controller 020-021 interrupt controller 1, master 022-023 chipset address 040-05f 8254 timer 060-06f 8042 (keyboard controller) 070-07f real-time clock, non-maskable interrupt (nmi) mask 0...

  • Page 43

    Ibc 2606 user's guide 43 b.10. 1st mb memory map table b-10:1st mb memory map addr. Range (hex) device f000h - ffffh system rom cc00h - efffh unused ca00h - cbffh used c000h - c9ffh expansion rom b800h - bfffh cga/ega/vga text b000h - b7ffh unused a000h - afffh ega/vga graphics 0000h - 9fffh base me...

  • Page 44

    44 ibc 2606 user's guide b.12. J2 connector pin assignments table b-12: j2 connector pin assignments pin row a row b row c row d row e 47 n/c n/c n/c n/c n/c 46 n/c gnd n/c n/c n/c 45 n/c n/c n/c gnd n/c 44 n/c gnd n/c n/c n/c 43 n/c n/c n/c gnd n/c 42 n/c gnd prst# req6# gnt6 41 n/c n/c deg# gnd n/...

  • Page 45

    Ibc 2606 user's guide 45 b.13. J3 connector pin assignments table b-13: j3 connector pin assignments pin row a row b row c row d row e 19 hdbd3 hdbd6 hdbd10 hdbd2 hd8d14 18 hdbd8 hdbd5 hdbd1 hdbd11 hdbd15 17 hdbd9 hdbd4 hdbd0 hdbd12 hdbd13 16 hdbdrq icsob# iiorb# ics1b# hdrdyb 15 dbdrq idackb# hdbsa...

  • Page 46

    46 ibc 2606 user's guide b.14. J4 connector pin assignments for ibc 2606 table b-14: j4 connector pin assignments for ibc 2606 pin row a row b row c row d row e 25 lan2tx- contx- usb-vcc1 usb-vcc0 usbd1+ 24 lantx+ lantx+ n/c usbd1- usbd0- 23 n/c n/c n/c n/c usbd0+ 22 usbrx- lanrx- n/c n/c comdtr2 21...