Intermatic PE45300 Supplementary Manual
158PE12767
ITEM
PT. NO.
DESC.
QUAN.
DR.: SRB 4/42006
INTERMATIC INCORPORATED
CHKD.: TJS 4/4/2006
SCALE: FULL
NAME:
INST SHT - DOOR, PE45300
APPROVED
MATL.:
SEE MATERIAL SPECIFICATIONS
2 REV ART TO REF NOTE 6 WAS 5
SRB 4/27/2006
2-TD 4/27/2006
FINISH:
BLACK PRINTING INK
1 RELEASED TO ELEC. DATA
HEAT TREAT:
LET.
REVISION
SIGN.
MODEL
SUPERSEDES:
FRACTIONS + .010 . DECIMALS AS SPECIFIED - ANGLES + 1/2˚
ALL DIMENSIONS MUST BE MET BEFORE PLATING.
DIM :
TOL
NOTES:
1. ALL PRINTING TO BE AS PER INTERMATIC
APPROVED ARTWORK, AND TO BE
CENTRALLY LOCATED ON LABEL.
D29
8.
25
”
6.
5
”
1/8 R. (4) OPTIONAL
MATERIAL SPECIFICATIONS:
1. WHITE VINYL WITH PERMANENT PRESSURE SENSITIVE
ADHESIVE BACKING. (.005” THICK)
SEE B/M FOR ALL PART NUMBERS & QUANTITIES
MODEL: PE45300
IIN
N R
RA
AIIN
NP
PR
RO
OO
OF
F ((T
TY
YP
PE
E 3
3R
R)) E
EN
NC
CL
LO
OS
SU
UR
RE
E F
FO
OR
R IIN
ND
DO
OO
OR
R//O
OU
UT
TD
DO
OO
OR
R U
US
SE
E..
SUITABLE FOR SWIMMING POOL/SPA APPLICATIONS AND FOR DIRECT CONNECTION TO A WET-NICHE OR NO NICHE LUMINAIRE.
125 amp. US/120 amp CANADA (If used as residential Distribution/Control equipment, not more
than 6 disconnects can be provided.)
120/240 volt or 120/208 volt single phase (three wire) AC
The short circuit rating of this panel is 10000 symmetrical amperes.
IMPORTANT:
This control panel must be installed according to the National Electrical Code (including article 680)
or Canadian Electrical Code (including section 68) and local code requirements. This installation is subject to the approval
by the local inspection authority. The main lugs and neutral main are suitable for No.14 to 2 AWG COPPER conductors.Use
No.14 to 6 AWG COPPER conductors for branch circuit wiring. Follow gauge selection table and corresponding terminal
screw tightening torque requirements below. Install interchangeable circuit breakers with an interrupting current rating of
10000 symmetrical amperes, or higher. All circuit breakers in this control panel shall be of the same manufacturer and type.
See list of suitable types below. Follow manufacturers instructions for installing and testing of ground fault circuit breakers
(GFCB) and interrupters (GFCI). Install only LISTED receptacle(s) and/or wiring device(s) inside the enclosure. A LISTED
wiring device may be installed in the rectangular side knockout provided. When panel is outdoors, a LISTED rainproof
cover must be installed over the wiring device in the side knockout. If this enclosure is used for direct conduit connection
to a wet-niche or no niche luminaire, one of the connection kits listed below in Note 6 must be used. This control should
not be connected to any equipment which would cause bodily injury or property damage should it be activated unexpectedly.
After wiring, install front panel over wiring compartment and close unused breaker openings with filler plates.
KEEP DOOR CLOSED AT ALL TIMES.
C
CL
LA
AS
SS
S C
CT
TL
L D
DIIS
ST
TR
RIIB
BU
UT
TIIO
ON
N //C
CO
ON
NT
TR
RO
OL
L
P
PA
AN
NE
EL
L W
WIIT
TH
H 3
3--C
CIIR
RC
CU
UIIT
T D
DIIG
GIIT
TA
AL
L C
CO
ON
NT
TR
RO
OL
L
INTERMATIC INCORPORATED
SPRING GROVE, ILLINOIS 60081-9698
158PE12767
3-CIRCUIT DIGITAL CONTROL RATINGS:
CLOCK SOURCE VOLTAGE: 120/240VAC, 50/60 Hz.
POWER CONSUMPTION: 6.0 Watts Max.
CONTACT CONFIGURATION: SPST - each circuit.
CONTACT RATINGS - EACH CIRCUIT (P1353ME)
-
17A Resistive - 120/240V AC
-
17 Full Load A, 80 Lock Rotor A - 120/240V AC
-
5A Tungsten, or Ballast 120/240V AC
-
Aux Switch: 2A, 24V AC
EVENTS PER CIRCUIT: 3 On/Off Events Per Circuit
MEMORY RETENTION:
• 40 Year retention for all programmed settings.
• 8-hour time retention.
VALVE / PUMP SWITCH MECHANISM (P4243ME) RATINGS:
CIRCUITS #1 & #2:
17A Resistive 120-240V, 10 A Tungsten-120V,
1.5 HP - 120V, 3 HP - 240V, 60 Hz; Double Pole Single Throw (DPST)
VALVE ACTUATOR SUPPLY: 24V - 40VA MAX.
SUITABLE LISTED BREAKERS
CIRCUIT BREAKER
FILLER
MANUFACTURER
SINGLE DOUBLE TWIN QUAD
GFCB
PLATE
CUTLER-HAMMER
BR
BR
BRD
BRD
GFCB
BRFP
MURRY
MP-T
MP-T
MH-T MH-T
MP-GT LX100FP
SIEMENS
QP
QP
QT
QT
QPF
QF3
SQUARE D
HOM
HOM
HOMT HOMT
HOM
HOMFP
THOMAS & BETTS
TB
TB
TBBD TBBQ
GFB FP-1C-TB
a
TORQUE CIRCUIT BREAKER LUGS TO VALUES SPECIFIED ON CIRCUIT BREAKERS
b
45 AMP FOR CANADA.
c
120 AMP FOR CANADA.
WIRING INFORMATION - COPPER CONDUCTORS ONLY
TERMINAL TORQUE
a
GENERAL
GENERAL
PURPOSE
MAX MOTOR
PURPOSE
BRANCH
SUPPLY
LINE AND
LOAD
BRANCH
CIRCUIT
WIRE SIZE
CIRCUIT
NEUTRAL NEUTRAL (CONTINUOUS
CIRCUIT
MAXIMUM
75˚C MIN
BREAKER
MAIN
AND
DUTY)
BREAKER
CURRENT
INSULATION
RATING
LUGS
GROUND
120V. 240V.
RATING
CAPACITY
AWG
AMP
LB-IN
LB-IN
HP HP
AMP
AMP
14
15
35
20
1/2 1
15
12
12
20
35
20
1 2
20
16
10
30
35
20
1 1/2 3
30
24
8
50
b
40
25
2 5
40
32
6
65
45
35
--- ---
60
44
4
85
45
35
--- ---
---
---
2
115
50
---
--- ---
---
---
2 (90˚C)
125
c
50
---
---
---
---
LR3730
UL508
UL1563
NOTES:
1. Any Intermatic T100M Series Time Switch, P1353ME mechanism, or
P4243ME mechanism may be installed in the bracket(s) provided or in
the event an existing mechanism(s) is replaced.
2. An additional ground bar may be installed in this control panel
(order 130T1318A).
3. If this control panel requires bonding, attach a LISTED bonding
terminal of a suitable size using the mounting hole(s) provided on the
bottom of the enclosure (156T11047A may be ordered).
4. When a circuit breaker is backfed, 22T904A Breaker Hold-Down Kit must
be used.
5. Wiring devices may be installed in this control panel (order 21T156A
(4) stand-offs for mounting).
6. The following kits are available to connect under water luminaires to this
enclosure:
1/2” non-metallic - order 156PA13713A
3/4” non-metallic - order 156PA13714A
1” non-metallic - order 156PA13715A
1/2” metallic - order 156PA14336A
7. Optional opening for Intermatic control device.