Kalvis 6 MPP User Manual

Manual is about: CENTRAL HEATING BOILER ON SOLID FUEL

Summary of 6 MPP

  • Page 1

    - 20 - barcode ® central heating boiler on solid fuel kalvis - 6 mpp with pellx burner user‘s manual lst en 303-5 ГОСТ 9817-95 Įst 144948958.13:2004.

  • Page 2

    - 2 - - 19 - f- 02/i n -04 to __ ___ ___ __ ___ ___ ___ ___ ___ ___ ___ __ guar an tee ser v ic ing re ques t havi ng acquai nted with firepl ace‘s “kalvi s________” user‘s manu al (products no.___ _____ ) and havi ng installed it as requ ired i h av e fo llo wi ng claims: 1. I conside r it a manufa...

  • Page 3

    - 18 - boiler sold by: company sales date: address phone boiler installed by: company address phone foreman (name, last name, signature) in case of a breakdown contact company address phone manufacturer uab “Šiaulių tauro kalvis” pramonės 15, lt-78137 Šiauliai, lithuania phone: (+370 41) 540556 e-ma...

  • Page 4

    - 17 - kalvis – 6mpp 2009.05.18 - 4 - 10. Certificate of acceptance boiler “kalvis-6mpp” factory no.__________ conforms to requirements of lst en 303-5, and Įst 144948958.13:2004 and is fit for comissioning. Boiler was tested at 0,4 mpa pressure. Hydraulic test date _____________________ date of man...

  • Page 5

    - 16 - user may purchase consumables from manufacturer of the boiler. Use only manufacturer‘s spare parts 8. Fuel types and properties combustion heat of absolutely dry wood does not depend on the kind of wood and equals 4510 kcal/kg. So in order to compare different kinds of wood we need to assume ...

  • Page 6

    - 6 - - 15 - kalvis – 6mpp 2009.05.18 when boiler is mounted outside the territory of lithuania, mountign and installation should proceed according to relevant national regulations. Error reason solution boiler overheats too intense combustion. Power outage (for systems with enforced circulation) cl...

  • Page 7

    - 14 - - 7 - kalvis – 6mpp 2009.05.18 boiler premises have to be well ventilated. Recommenmded fuel humidity not greater than15-20 %. Notice. At the start of operation, until there is no soot layer on the internal boiler surfaces, during combustion a water condensate may form, giving the impression ...

  • Page 8

    - 8 - 4.3. Connection to heating system recommended connection method is shown in the 4a-4d fig • boiler may be connected to the heating system according to the project prepared by heating equipment specialists or works may be performed by a well qualified plumbing welder who is well acquainted with...

  • Page 9

    - 12 - - 9 - kalvis – 6mpp 2009.05.18.

  • Page 10

    - 10 - - 11 - kalvis – 6mpp 2009.05.18.