    G-sa060-002 kaneka thin film pv installation manual module type: g-sa060 kaneka corporation 3-2-4, nakanoshima, kita-ku osaka 530-8288, japan reference no. G-sa060.002 http://www.Wholesalesolar.Com/solar-panels.Html.

  • Page 2: Warning

    G-sa060-002 warning meaning of signs not allowed no disassembly no touching procedures must be followed. Beware of electric shock do not disassemble kaneka thin-film silicon photovoltaic module(s) (hereinafter referred to as the module(s)), as this may cause fire, electric shock, and injury. Do not ...

  • Page 3

    G-sa060-002 1.Dimensions K AN E K A C or p o ra t i on USER TITLE DWG NO. UNITS SCALE DWN. CHK. APR. DATE SIGN REVISIONS DATE SYM 3RD ANGLE PROJECTIO N 2 004. 06.11 1: 10 m m G- SA Mod ule DS-GSA NAKAJIMA Front View 990 ±2.5 9 6 0 ±2. 5 40 ±1 Gr oun din gHol es 15 0 66 0 2-φ4 24 942 480 4-φ6 Dr ainH...

  • Page 4

    G-sa060-002 2.Electrical characteristics of modules product:thin-film silicon pv module model: g-sa060 date: april 01, 2006 specification lists unit value remark performance at stc (stabilized) nominal power (pmax) w 60.0 open circuit voltage (voc) v 92.0 open circuit voltage (voc) at -10°c and 1250...

  • Page 5

    G-sa060-002 3. Specifications subject to change without notice. 4. Under normal conditions, the modules may experience conditions that produce more current and/or voltage than reported at standard test conditions. Accordingly, the values of isc and voc marked on ul listed modules should be multiplie...

  • Page 6

    G-sa060-002 3.Installation of the modules the assembly is to be mounted over a fire resistant roof covering rated for the application. 5 in/ft (127mm/305mm) required to maintain ul fire class rating. Artificially concentrated sunlight shall not be directed on the module. See the attachment a: instru...

  • Page 7

    G-sa060-002 recommended mounting system for installation method 2 is “solar mount /s-5! Pv clamp sets” made by unirac, inc. Install the mounting system as instructed by a installation manual of the mounting system. (refer to installation manual provided by unirac.) then, fix the modules with the cra...

  • Page 8

    G-sa060-002 4.Connecting cables use 14 awg minimum, insulated for 90℃ minimum cables. Stranded copper only. When connecting cables, push the plus and minus connectors against each other while twisting them until they are fully engaged. Plus cable connector: pv-kst3ii ur (multi-contact usa) minus cab...

  • Page 9

    G-sa060-002 1. Press a stainless steel nut with a star washer and a 10-32 thread into the ground holes (marked ‘gr’) on the back of frame. 2. Install a ground lug such as the shown ilsco gbl-4dbt which is ul listed. (user-provided) 3. A screw shall be used to secure a ground lug as described in the ...

  • Page 10

    G-sa060-002 7.Limitation see the attachment a: instruction for using g-type (ul grade). Http://www.Wholesalesolar.Com/solar-panels.Html.