    Table of contents i. Introduction..........................................................................(1) ii. Definition............................................................................(3) iii. Precautions of operation.....................................................(4) iv. Main ...

  • Page 3: I. Introduction

    I. Introduction ks-200b computer-controlled wireless alarm system is a type of long-distance wireless alarm system, which is composed of an alarm host and 1 to 100 detectors. All these constitute a complete set of region alarm service system which can be widely used for industrial and mining enterpr...

  • Page 4

    Function and can switch between ac and dc. Ks-200at /ks-200act wireless infrared detector ĂĂ ĂĂ ĂĂ .$5$6616(&85,7 ks-200ati wireless infrared detector ks-200dct ks-200ect ks-200fct wireless infrared detector ks-200bti wireless infrared detector ks-200bct wireless infrared detector ks-10a ks-10b wire...

  • Page 5: II. Definition

    Ks-200act wireless infrared detector adopts double infrared inductor together with single chip processing technology as well as the automatic temperature compensation technology, which make it have the advantages of low error alarm ratio and extremely high anti-interference capability. Ks-200act-c i...

  • Page 6

    The advantage of this function is to come true the wireless relaying emitter and decrease the system cost. For example, the users have to install 10 detectors for one floor. Usually, it need to 10 ks-200act detectors and 10-backup power for these detectors and ac power. If the users use the wireless...

  • Page 7

    2. 1-100 independent wireless defense area can be defined and the defense of each defense area can be activated or deactivated independently. Common defense area and emergent defense area can be defined at will. 3. The alarm host has two sets of timing switch on/off time and also current on/off stat...

  • Page 8

    "function" key. "function" key, press "function" key to switch between function setup options. They are totally eight function options. For detailed function description, please refer to the related content of " operations" chapter. " ˚ " key, is used to complete function setup together with "functi...

  • Page 9

    Alarm output interface: a set of normal open and a set of normal close alarm output and a set of uncontrolled + 12v 300ma output. Normal open, normal close alarm output interface-label on the rear panel the alarm host provides alarm output contact loaded 1a120vac or 3a30vdc. It is use to control oth...

  • Page 10

    Infrared sensitivity selection jumper: if the jumper is inserted at "h" position, the effective detection distance is 8 to 12 meters. If the jumper is inserted at "l" position, the distance is about 4 to 8 meters. Backup power input: the allowable input power voltage is 12-13.8v. Ac power supply inp...

  • Page 11

    Ac power input. Dc power input: the input bearer has f l o a t i n g c h a r g e d e v i c e , w h i c h c a n b e connected with chargeable batteries or a storage battery when the backup battery is not selected. Double infrared sensor. Address code switch: it is used to change the address code. Ple...

  • Page 12: Vii. System Installation

    Seconds. At the same time, the detector will sends out an on-site alarm for 30 seconds, and then it will automatically stop. The optional remote controller can be used to activate or deactivate defense state and set emergency alarm operations. Vi. Interface performance and system connection 1. Ks-20...

  • Page 13

    1. Basic requirement of system installation design (1) suitable types and models of detectors should be adopted during installation design period according to the user requirement of defense areas. (2) the installation location, angle and height of a detector should be determined according to the ef...

  • Page 14: Viii. Operation Guide

    Machines and etc. Stand off the windows. There is no barrier within the defended area of a detector. The detector should be parallel with the wall surface. (2) installation of alarm host the alarm host should be placed on a table near a window in so far as possible. The alarm host is not explosion-p...

  • Page 15

    2. Programming setup of alarm host after it is power on, the display screen of the alarm host shows "12:00 00". The second light is flashing and the last two bits display second. Press the "function" key to enter into setup mode, in the mean while, the second light is continuously on and the last tw...

  • Page 16

    Function 3 shutdown time of the first group hour press ˘key to set minute press ˚key to set group is 12:00. Note: auto startup time means that the alarm host will automatically enter into security mode (defense state) and begin to receive alarm signals when the configured time arrives. (3) set auto ...

  • Page 17

    Group is 18:00 (5) set auto shutdown time of the second group enter into "auto shutdown time of the second group" setup mode, press " ˘ " or "˚ " key to adjust the auto shutdown time of the second group. After the setup is finished, press "reset" key to exit or press "function" key to set "defense-a...

  • Page 18

    Key to select defense-activated state. "00" means that defense is deactivated in the defense area and "01" means that defense is activated in the defense area. It should be noted that, no matter the defense area is common defense area or emergent defense area, all the alarm signal won't be received ...

  • Page 19

    Ks-200bmi alarm host and ks-200bm alarm host are the same setup grogram. The telephone alarm function setup is used to alarm host connect the external telephone machine. More details please refer to the following: note the telephone used to program should be dtmf (double tone multi-frequency) phone....

  • Page 20

    Change the telephone machine. After press # # #, if there is a rapid sound "beep---beep---". Usually, it is a wrong between the telephone machine and line socket. And cause an open circuit alarm. Please connect again. No operation within 20 seconds in the setup state, the system will automatically e...

  • Page 21

    Number. Press 16 # c c c c c c # to set the 6th group of informed telephone number. Press 17 # c c c c c c # to set the 7th group of informed pager number. Press 18 # c c c c c c # to set the 8th group of informed pager number. The above "c c c c c c" is the telephone (or mobile phone or pager) numb...

  • Page 22

    12#1234567**801# 13#13900000012# (4) dele informed telephone number press 11# # to dele the 1st group of informed telephone number. Press 12# # to dele the 2nd group of informed telephone number. Press 13# # to dele the 3rd group of informed telephone number. Press 14# # to dele the 4th group of inf...

  • Page 23

    ("at xx garden" is recorded by the users at 30# for 10 seconds. For details, please refer to "record operation"). Then you will hear an indicative sound "beep". The system will take 20 seconds to wait the command. If the alarm voice is not clear, press 5# to replay. After an indicative sound "beep",...

  • Page 24: X. Optional Parts List

    X. Optional parts list 1. Wired infrared detector, wired infrared door sensor. 2. Ks-200at wireless infrared detector (adopts special infrared processing chip) 3. Ks-200act wireless infrared detector (adopts single chip processing technology) 4. Ks-200ati wireless infrared detector (adopts single ch...

  • Page 25

    Xi. Simple failure recovery fault symptom failure reason failure recovery no cue tone and clock display when power on is the power socket bad connection or does it have no power supply? Or, is the fuse burnt out? Check the plug and socket, check the fuse and replace it the backup batteries don't wor...

  • Page 26: Defense Area Table

    Defense area table zone no. Zone location zone no. Zone location zone no. Zone location.