    2 dear customer, we want to thank you for choosing one of our production stoves for your purchase. We are confident that we supplied you with a technologically valid product. In the following pages, we provide you with some instructions, so that you may know and use the product at its best, as well ...

  • Page 3

    3 a. General information a.1 general safety rules a.2 technical features a.3 accessory equipment a.4 identity plate a.5 guarantee a.6 suitable fuel a.7 ordering spares a.8 waste material b. Installation instructions b.1 initial warnings b.2 moving and transporting b.3 positioning b.4 installing the ...

  • Page 4

    4 d.7 room probe d.8 sparking plug d.9 thermocouple e. Ordinary cleaning and maintenance e.1 cleaning and maintenance by the customer e.2 periodic maintenance by the assistance center f. Alarms displaying f.1 fumes temperature probe alarm f.2 unsuccessful lighting alarm f.3 switching-off while worki...

  • Page 5

    5 a. General information a.1 general safety rules attention please!!! You can never be too cautious: before the installation read and comply with these fundamental rules: • all local regulations, including those referring to national and european laws, must be respected while installing the stove. •...

  • Page 6

    6 ● in order to facilitate the possible interventions by the technical assistance, do not fit the stove inside closed spaces and do not place it adjacent to the walls, for this may compromise the correct afflux of the air. ● the lack of draught by the flue (or, for instance, the obstruction or closi...

  • Page 7

    7 a.2 technical features in the following pages, we provide you with a list explanatory of the technical features: nominal power: 10kw efficiency: 87% power supply: 230v 50hz power absorption: 127-290w pellet tank capacity: 20kg co measured at 13% of oxygen at nominal thermal power: 0,01% pellet con...

  • Page 8: Alice

    8 alice 1 rear fumes outlet 2 side fumes outlet 3 upper fumes outlet.

  • Page 9

    9 a.5 guarantee the guarantee certificate, which we consigned to you when you purchased the stove, must be sent to the producer firm karmek one srl, 8 days after delivery date the latest; otherwise, the guarantee itself will no longer be valid. The estimated 24-months guarantee is valid exclusively ...

  • Page 10

    10 a.8 waste material do not drop electrical devices among domestic waste. According to the european directive 2002/96/ce regarding electrical and electronic devices’ waste material, and its application in conformity to national regulations, exhausted electrical devices must be collected separately,...

  • Page 11

    11 for safety reasons, maintain a distance of at least 20cm between the hot sides of the stove and possibly inflammable covering materials (such as glass-beaded walls, wallpapers et cetera); otherwise, use specific insulating materials, available on sale. L=20 cm min. B=20 cm min. R=20 cm min. B.4 i...

  • Page 12

    12 combustion air is drawn from the inside combustion air is drawn from the inside installation without a masonry flue installation with an existing flue masonry flue steel piping.

  • Page 13

    13 b.5 installing the combustion air inlet pipe for any described solution, two alternatives are possible: ● draw the air directly from the outside through a piping (internal Ø 50mm; max length 1,5m), connected to the air inlet pipe on the back of the stove. ● draw the air directly from the installa...

  • Page 14

    14 electrical scheme.

  • Page 15: C.1 Initial Warnings

    15 c. Operating instructions c.1 initial warnings all regulations, included those referring to national and european laws, must be respected when installing the device. Do not use the device as an incinerator or in any other way than that for which it was designed. Do not use any fuel other than pel...

  • Page 16

    16 c.3 display in the following scheme, we report the various functions of the display. Important: if the temperature is not set within a few seconds, the display will automatically return to the previous screenshot..

  • Page 17

    17 c.4 lighting the stove for the first time a skilled technician must perform the first lighting; otherwise, the guarantee will expire. C.5 activating the stove when the pellet tank is filled for the first time, you must remember that the screw tube, which feeds the grate, is completely empty; ther...

  • Page 18

    18 c.7 switching off the stove you can switch the stove off by pushing the key n. 4 for a few seconds. The message “off” will appear on the display; the pellet flow is interrupted and the speed of the smoke intake motor will increase to lower the temperature. The stove will complete its cycle and wi...

  • Page 19

    19 c.9 managing the automatic lighting (chronothermostat) the automatic lighting function permits to weekly program the lighting and switching off of the stove. Through this function, it is possible to set two daily lightings; it is also possible to avoid extra programming, by memorizing the set dat...

  • Page 20

    20 ut08/ut09: they indicate the starting and stopping time of the program 2, if the ut01 setting is set on the weekly mode (different from off) ut10: it modifies the weekdays you wish the program 2 to be on. By pressing the “2” key you run over the days, and by pressing the “1” key you set or unset ...

  • Page 21: Components

    21 d. Functions of the mechanical and electric components d.1 screw motor the screw motor drives the screw, which brings the pellets from the tank to the grate. D.2 smoke intake motor the smoke intake motor is fixed on the extraction turbine on the back of the stove. Its function is to intake and to...

  • Page 22

    22 d.6 fumes probe the fumes probe surveys the fumes’ temperature in the intake turbine, and it operates when the temperature reaches 270°c, driving the stove to the conservation mode “ris” d.7 room probe the room probe is positioned on the back of the stove and it surveys the temperature of the roo...

  • Page 23

    23 e. Ordinary cleaning and maintenance e.1 cleaning and maintenance by the costumer before lighting the stove, it is advisable to clean the inside of the stove. ● open the door and vacuum the fire table. ● remove the great, verify its cleanliness and clean the holes if necessary. ● vacuum the grate...

  • Page 24: F. Alarms Displaying

    24 f. Alarms displaying the alarms are displayed on the command panel; on the first line the message alar appears, while on the second line the typology of the anomaly is displayed. The occurring of an alarm provokes the immediate stop of the stove, and only after solving the problem it is possible ...

  • Page 25

    25 g. Solution to possible problems problem possible cause solutions the display is blank and the keys do not work. Lack of power. Anomalies in the connection between the display and the card. Check if the power supply cable is connected. Check if the display and the card are properly connected. The...

  • Page 26

    26 problem possible cause solutions the stove is blocked for an unsuccessful pellet supply. Technical problem with the screw. Important: unplug the stove before - ridding the screw of possible obstructions - ridding the chute of possible obstructions - removing the pellet dust accumulation from the ...

  • Page 27

    27.

  • Page 28: Guarantee Conditions:

    Legal head office: via martiri delle foibe, 17 31015 conegliano (tv) phone 0438 1883101 fax 0438 1883103 e-mail info@karmek.It guarantee conditions: at the end of each season, it is obligatory to have the authorized assistance center perform a general cleaning of the stove; otherwise, the guarantee ...