Kaufman KM-25 User Manual

Manual is about: NON-CONTACT THERMOMETER

Summary of KM-25

  • Page 1

    N on -c ontact thermometer m odel : km-25 0482.

  • Page 2

    Visiomed - kaufman km-25 - v.2.3 -201012 2/21 t able of c ontents i. S afety i nstructions ………………………………………………… 21 ii. I ntroduction ………………………………………………… 22 iii. P recautions before use ………………………………………………… 22 iv. O perating p rinciples ………………………………………………… 23 different methods of temperature measuremen...

  • Page 3

    Visiomed - kaufman km-25 - v.2.3 -201012 3/21 i. S afety i nstructions - follow the maintenance instructions set out in this notice - the device is intended for personal use at home or in medical practice. It is not recommended for heavy use in a professional setting. - the device should only be use...

  • Page 4

    Visiomed - kaufman km-25 - v.2.3 -201012 4/21 ii. I ntroduction the kaufman km-25 non - contact thermometerwas developed using the latest infrared technology. This technology allows a temporal artery (ta) temperature to be taken at a distance of about 5 cm from the forehead. Accurate, instant and no...

  • Page 5

    Visiomed - kaufman km-25 - v.2.3 -201012 5/21 iv. O perating p rinciple all objects, solid, liquid or gas, radiate energy whose intensity varies in relation to its temperature. The kaufman km-25 thermometer measures the temperature of a person based on the energy that they radiate. A temperature mea...

  • Page 6

    Visiomed - kaufman km-25 - v.2.3 -201012 6/21 oral thermometry oral temperature is easily affected by recent ingestion of food and drink and by breathing through the mouth. To take temperature orally, the mouth needs to be closed and the tongue depressed for between three and four minutes, this is a...

  • Page 7

    Visiomed - kaufman km-25 - v.2.3 -201012 7/21 advantages of using temporal artery (ta) temperature infrared arterial temperature can be measured using a device placed on the forehead in the temporal artery region. It has been shown that this relatively new method of measuring temperature is more acc...

  • Page 8

    Visiomed - kaufman km-25 - v.2.3 -201012 8/21 practical considerations when taking a temperature - to ensure a precise and accurate temperature measurement, it is important that the user has received adequate training and information regarding the temperature measurement technique for the device. - ...

  • Page 9

    Visiomed - kaufman km-25 - v.2.3 -201012 9/21 f or reliable results before taking a temperature reading and to ensure a stable and reliable result: - push aside hair from the forehead - wipe away any perspiration on the forehead - avoid drafts (e.G. Nasal cannula, air conditioning etc.) - wait 1 min...

  • Page 10

    Visiomed - kaufman km-25 - v.2.3 -201012 10/21 vi. Description of the kaufman km-25 thermometer infrared sensor lcd screen measure button mesure battery compartment advanced configuration buttons.

  • Page 11

    Visiomed - kaufman km-25 - v.2.3 -201012 11/21 vii. F unctions 1. Designed to take body temperature readings. 2. Stable and reliable results due to advanced infrared system using automatic calibration. 3. Alarm sounds if temperature is exceeded. 4. Display of measurement results : - measurement rang...

  • Page 12

    Visiomed - kaufman km-25 - v.2.3 -201012 12/21 viii. S etup & m enu f unctions o ption buttons the km-25 thermometer is specially designed to take the body temperature of children or adults without touching the body. It can be used at home or by health professionals. To take body temperature use the...

  • Page 13

    Visiomed - kaufman km-25 - v.2.3 -201012 13/21 s etting up the k aufman km-25 thermometer 1. Temperature units press the prog button for 3 seconds, the screen will show: c-f. Press ‘-’ to choose celsius, or ‘+’ for fahrenheit. Confirm selection by pressing the prog button. 2. Total temperature varia...

  • Page 14

    Visiomed - kaufman km-25 - v.2.3 -201012 14/21 b: body mode s: surface mode m : memory 01-32 : index 4. D ata m emory to display the last saved temperature measurements press the ‘-’ button for 3 seconds. This will display the last temperature measurement. To scroll through saved measurements press ...

  • Page 15

    Visiomed - kaufman km-25 - v.2.3 -201012 15/21 ix. T echnical & p recision information 1. Normal operating conditions : operating temperature: body temperature: 10°c ῀ 40°c surface temperature: 0°c to 50°c humidity : 10~93% rh 2. Power : dc 3v (2 aaa batteries) 3. Dimensions : 170 x 57 x 37 mm (l x ...

  • Page 16

    Visiomed - kaufman km-25 - v.2.3 -201012 16/21 x. A dvice - the infrared sensor (lens) is the most important and most fragile part of the thermometer, please take care of it. - clean the lens with a cotton cloth, moistened with water or 70 ° rubbing alcohol. - only use recommended batteries, do not ...

  • Page 17

    Visiomed - kaufman km-25 - v.2.3 -201012 17/21 result too high / too low check if the total variation has been modified (see page 13). Default setting is : 0.0 the thermometer can compensate for temperature differences due to changes in environment. Leave the thermometer in the ambient temperature f...

  • Page 18

    Visiomed - kaufman km-25 - v.2.3 -201012 18/21 g uarantee k aufman will repair or replace this product free of charge in the case of defective parts or manufacturing defects, in accordance with the conditions mentioned below as follows: duration: 24 months return to workshop limits and exclusions: t...

  • Page 19

    Visiomed - kaufman km-25 - v.2.3 -201012 19/21 purchase date: serial number: retailer’s seal: this warranty card will not be re-emitted sn : …………………………………. Date : ….. / …… / …….. Stamp:.

  • Page 20

    Visiomed - kaufman km-25 - v.2.3 -201012 20/21 en gl is h disposal of waste equipment by users in private households in the european union the symbol on the product or on its packaging indicates that this product must not be disposed of with your other household waste. Instead, it is your responsibi...

  • Page 21

    Visiomed - kaufman km-25 - v.2.3 -201012 21/21 visiomed france division kaufman - service clients 21 avenue victor hugo 75116 paris– france tel : 0892 680 180 fabriqué en chine / made in china bannex limited 2910 excellence times square yi tian road futian cbd shenzhen chinau k aufman is a patented ...