KEDDY 100 Installation Instructions Manual

Summary of 100

  • Page 1

    Inserts installation instructions care and firing instructions model 100, 200

  • Page 2: Table of Contents

    Table of contents certificate .........................................................................................................................2 general................................................................................................................................3 important ...

  • Page 3: General Information

    General information thank you for choosing an insert from keddy! The inserts from keddy has a number of unique characteristics, for example: * grounded doors * pre-heated combustion air * cast iron for long service life there are the following accessories for the inserts: * guard of forged steel * g...

  • Page 4: Prerequisites

    Prerequisites building notice when you install a stove and/or erect a chimney, you may have to give building notice to the local planning and building committee. Contact the planning and building committee in your municipality for up-to- date information. Flue inserts from keddy must be connected to...

  • Page 5: Installation Instructions

    1. Before starting the installation, determine where in the flue the mineral woll seal should be placed . Clean the inside of the hood with a steel brush remo- ving soot and loose mortar. Remove the old damper if it is an obstruction during installation. 2. Fix the support leg to the flange of the f...

  • Page 6

    4. Important! Be thorough in placing mineral wool between the chimney walls and the upper tube. This ensures that no heat is lost up into the chimney.Place two thin wooden bars on the bottom of the open fire- place. Place the insert on the wooden bars and apply joint glue to the connection on top of...

  • Page 7: Care & Firing Instructions

    7. The installation is now finished. Make a final check that joints are tightly sealed and that the mineral woll is in a correct position. The space between the insert and the open fireplace can be fitted with the keddy guard of punshed steel or forged steel.(accessories). Both guard systems can be ...

  • Page 8

    Wood quantity at normal firing insert model 100 2 kg/hour insert model 200 2,5 kg/hour wood quantity at maximum firing insert model 100 3 kg/hour insert model 200 3,5 kg/hour firing instruction 1. Open the door. Put in some crumpled newspaper or firelighters. 2. Put in 3,0 kg of kindling. Pile up th...