La Gard 8130 Installation Instructions

Manual is about: ELECTRONIC ENTRY DEVICE

Summary of 8130

  • Page 1

    To ensure problem free installation and application, please read these instructions thoroughly before installing the 8130 entry device and lock. 8130 entry device parts • 8130 entry device w/cable assembly • metric hardware kit • 2 position shunt (jumper) • m4-0.7 5.5 mm diam x 5.5 mm shoulder screw...

  • Page 2

    (p/n)738.098 rev a • 04/09 © copyright 2009 kaba mas llc page 2 of 5 design parameters for swing bolt locks 1. Bolt dimensions (nominal): .309 inches x .900 inches/7.8 x 22.8mm 2. Bolt movement (nominal): .465 inches/11.8mm 3. Bolt extension: .465 inches/11.8mm 4. Maximum load movable by the bolt: n...

  • Page 3

    (p/n)738.098 rev a • 04/09 © copyright 2009 kaba mas llc page 3 of 5 entry device mounting standard method the 8130 entry device comes with a backplate for ease of mounting. (figure 1) 1. Locate, drill and tap holes to mount the entry device to the outside of the safe door using the installation tem...

  • Page 4

    (p/n)738.098 rev a • 04/09 © copyright 2009 kaba mas llc page 4 of 5 5. Connect the cable coming from the entry device directly into the connector port marked ent on the lock. (figure 6) dead bolt or spring bolt locks in order to use either the dead bolt or spring bolt locks, a method of retracting ...

  • Page 5

    10. Remove the mounting screw from the system card, and gently lift the system card out of the case. (figure 12) 11. Insert the spindle through the spindle hole in the front of the door. 12. With the bolt retracted, carefully thread (clockwise) the spindle into the drive cam of the lock assembly unt...