  • Page 1

    La spaziale s1 vivaldi ii double boiler espresso machine owner’s manual rev d (covers vii’s with and w/o enhanced temperature offset and programmable preinfusion) updated on 5/30/10 to clarify that extreme temp mode setting are not “sticky”.

  • Page 2

    S1 vivaldi ii owner’s manual table of contents 1 feature overview ..................................................................................................... 1 2 reference photos .................................................................................................... 2 3 docume...

  • Page 3: 1  Feature Overview

    S1 vivaldi ii owner’s manual page 1 1 feature overview dual boiler steam boiler 2.5 liter steam boiler element 1250 watts group boiler .45 liter group boiler element 800 watts direct plumbed rotary pump volumetric dosing adjustable through touch pad group temperature indicated by lamp display group ...

  • Page 4: 2  Reference Photos

    S1 vivaldi ii owner’s manual page 2 2 reference photos these numbered photos will be referenced throughout the document; i.E. (13) figure 1 – indicator lights and control buttons.

  • Page 5

    S1 vivaldi ii owner’s manual page 3 label function label function label function label function 1 drip tray 8 cup warming tray 15 92 c lamp 22 on/standby lamp 2 steam arm 9 control panel 16 93 c lamp 23 hot water button 3 rubber feet 10 group 17 94 c lamp 24 single cup button 4 steam/group pressure ...

  • Page 6

    S1 vivaldi ii owner’s manual page 4 multiple kitchen outlets are on the one 20a circuit. Often this means the refrigerator outlet. 20a vii owners should contact their electrician if unsure how to proceed. The internal switch which places the vii in 15a mode does so by never allowing the group boiler...

  • Page 7

    S1 vivaldi ii owner’s manual page 5 4. From the front of the machine look down into the top of the machine. In the right rear of the machine you will see a toggle switch with its positions labeled 15 and 20. Reach down with the same screwdriver you used to remove the cup warming tray and flip the sw...

  • Page 8

    S1 vivaldi ii owner’s manual page 6 tip the vii on its side. Twist all four rubber feet (3) hand tight as they may vibrate loose during shipping. While performing that task, use a screwdriver to ensure that the four screws on the bottom (two on each side between the rubber feet) which fasten the two...

  • Page 9

    S1 vivaldi ii owner’s manual page 7 3) the light corresponding to the set temperature starts flashing to indicate that the group is heating and the automatic boiler refill starts until the water level preset by the manufacturer is reached. 4) once the filling process is finished, the boiler light (1...

  • Page 10

    S1 vivaldi ii owner’s manual page 8 suggestion. Many users only pull double shots and program the double shot button for 1.5-2.0oz for that purpose. Then they program the single cup button for a larger amount for use in flushing the portafilter basket and/or the group between shots. The beauty of th...

  • Page 11

    S1 vivaldi ii owner’s manual page 9 warning!! Do not turn the steam knob (6) before placing the steam wand (2) inside the pitcher, in order to avoid burns. 4.8 economy / boiler operational modes on the 20 amp models of the laspaziale vii, the boiler button performs two standard roles: 1. Turning the...

  • Page 12

    S1 vivaldi ii owner’s manual page 10 8. To exit economy mode, press and hold the boiler button for 10 seconds until the econ lamp is extinguished. 4.9 v1/vii mode switch the vii controller board actually has a backward compatible mode that emulates the functionality of the original vi. None of the a...

  • Page 13

    S1 vivaldi ii owner’s manual page 11 temperature indicated by the temperate lamps exactly matches the water temperature exiting the group. Laspaziale has partially accounted for this in its basic design. However, there are too many machine to machine electrical and mechanical variances for this to b...

  • Page 14

    S1 vivaldi ii owner’s manual page 12 see table below: offset 91ºc lamp 92ºc lamp 93ºc lamp 94ºc lamp 95ºc lamp 96ºc lamp 97ºc lamp econ lamp 0ºc off off off off off off off off -1ºc on off off off off off off off -2ºc on on off off off off off off -3ºc on on on off off off off off -4ºc on on on on o...

  • Page 15

    S1 vivaldi ii owner’s manual page 13 the offset was +3˚c. By pressing double cup the offset has changed to +2˚c. -8 -7 -6 -5 -4 -3 -2 -1 0 +1 +2 +3 +4 +5 +6 +7 +8 ˚c offset ---------------------------------------------------------- single cup button --------------------------------------------------...

  • Page 16

    S1 vivaldi ii owner’s manual page 14 note that the method below only works if the master temperature is set to either 91ºc or 97ºc. If the temperature is set to 91ºc you can only use the instructions below to lower the temperature by 1ºc, 2ºc, or 3ºc. If the temperature is set to 97ºc you can only u...

  • Page 17: 5  Alarm Handling

    S1 vivaldi ii owner’s manual page 15 group water solenoid opens and when the pump is activation. This is the preinfusion time. If none of the lamps 14-21 are lit, the preinfusion time is 0 seconds which means no preinfusion. Each press of the boiler button (13) increases preinfusion time by 1 second...

  • Page 18

    S1 vivaldi ii owner’s manual page 16 5.3 steam boiler temperature detection system failure (only with the boiler turned on) this is a blocking alarm and occurs when the temperature probe of the boiler is in short circuit (temperature >145°c) or it is in open circuit (disconnected) condition (tempera...

  • Page 19: 6  Connection Diagrams

    S1 vivaldi ii owner’s manual page 17 6 connection diagrams 6.1 electrical connection diagram.

  • Page 20

    S1 vivaldi ii owner’s manual page 18 6.2 control board connection diagram 6.3 triac board connection diagram boiler triac bd group triac bd (cooling fan is below this board and runs only when boiler is heating).

  • Page 21

    S1 vivaldi ii owner’s manual page 19 6.4 control panel connection diagram 6.5 wiring diagram definitions ev gr coffee brewing group solenoid valve ev h hot water delivery solenoid valve ev al automatic refill system solenoid valve t1 connection on control board of the triac that feeds the boiler hea...

  • Page 22

    S1 vivaldi ii owner’s manual page 20 7 vii water flow diagram the information below is provided strictly as a reference for vii owners who are curious about the function of their vii dual boiler design..

  • Page 23

    S1 vivaldi ii owner’s manual page 21 8 adjustments and maintenance 8.1 external vii surface cleaning use a damp sponge and wipe dry with a soft cloth. Alternately, window cleaner wiped off with a dry soft cloth works well. 8.2 routine group cleaning the extra pair of shower screens was not included ...

  • Page 24

    S1 vivaldi ii owner’s manual page 22 you grind too fine and choke the machine. So the instant this condition is sensed is the ideal point at which to engage the 3-way valve.) perform the above cycle 5 times waiting about 30 seconds between each cycle. Then rinse the remaining detergent from the bask...

  • Page 25

    S1 vivaldi ii owner’s manual page 23 8.3 group pressure test and adjustment this adjustment and the one covered in the next section require that use of a portafilter with the rubber disk or blind filter basket. (the same one used for back flushing.) for clarity the portafilter is not shown in the ph...

  • Page 26

    S1 vivaldi ii owner’s manual page 24 8.4 expansion valve release adjustment this procedure starts by removing the chrome front panel as in the above procedure and also requires the portafilter with rubber disk or blind filter basket. 1. Adjust the group pressure to 12.5 bar per the following instruc...

  • Page 27: 9  Optional Accessories

    S1 vivaldi ii owner’s manual page 25 9 optional accessories these can be ordered and installation arranged at the time you order the v2. In addition, they can be ordered latter and self-installed if you are the handy with simple metric tools. Pre-infusion chamber normally v2 users will use the integ...

  • Page 28

    S1 vivaldi ii owner’s manual page 26 longer steam arm (shown next to stock arm).

  • Page 29

    S1 vivaldi ii owner’s manual page 27 optional “no burn” steam arm (shown next to stock steam arm) 10 other laspaziale vii resources in addition to your vii supplier, current users are an excellent information resource: check out these internet sites: http://www.Home-barista.Com – reviews, forums, an...

  • Page 30: 11  Quick Setting Guide

    S1 vivaldi ii owner’s manual page 28 11 quick setting guide.