La Spaziale S1 Vivaldi Owner's Manual

Manual is about: Double Boiler Espresso Machine

Summary of S1 Vivaldi

  • Page 1

    La spaziale s1 vivaldi double boiler espresso machine owner’s manual last updated on 03/31/2014.

  • Page 2: S1 Owner’S Manual

    S1 owner’s manual table of contents 1 feature overview ..................................................................................................... 1 2 reference photos .................................................................................................... 1 3 basic machine ope...

  • Page 3: S1 Owner’S Manual

    S1 owner’s manual page 1 1 feature overview dual boiler steam boiler 2.5 liter steam boiler element 1250 watts group boiler .45 liter group boiler element 800 watts direct plumbed rotary pump volumetric dosing adjustable through touch pad group temperature indicated by led display group temperature ...

  • Page 4: S1 Owner’S Manual

    S1 owner’s manual page 2 label function label function label function label function 1 drip tray 8 warming tray 15 90 c lamp 22 on/standby lamp 2 steam arm 9 control panel 16 95 c lamp 23 hot water button 3 rubber feet 10 group 17 100 c lamp 24 one cup button 4 boiler pressure 11 portafilter handle ...

  • Page 5: S1 Owner’S Manual

    S1 owner’s manual page 3 3 basic machine operation 3.1 15a or 20 amp operation the laspaziale s1 is available in 15a and 20a versions. In actuality, they are both identical machines. There is an internal switch that selects the operating mode and they have different power cords installed. The power ...

  • Page 6: S1 Owner’S Manual

    S1 owner’s manual page 4 contact your s1 vendor for advice if the solution isn’t obvious. Also, your s1 vendor may request that you check that your water hardness is below a certain level to ensure long life and trouble free operation. Hardness test strips may be included for this purpose. If your w...

  • Page 7: S1 Owner’S Manual

    S1 owner’s manual page 5 warning!! To activate and deactivate the boiler mode press the "boiler" (26) button. Every time you turn on the machine, the boiler is in service. When the boiler is turned off, it is impossible to use hot water for infusions or steam delivery. The machine can also operate i...

  • Page 8: S1 Owner’S Manual

    S1 owner’s manual page 6 previously been programmed.) 3. To increase the temperature, press the boiler (13) button. The first press lights the yellow lamp over 110 (19) which indicates +1°c. A 2 nd press also lights the red lamp over 120 (20) which indicates +2°c. A 3 rd press also lights the red la...

  • Page 9: S1 Owner’S Manual

    S1 owner’s manual page 7 3.6 volumetric dose programming the programmable volumetric dosing feature allows programming of the single shot (24) and double shot (25) buttons to dispense whatever quantities of espresso the user desires. Their use for single shot and double shot quantities is merely a s...

  • Page 10: S1 Owner’S Manual

    S1 owner’s manual page 8 3. At the end of the heating phase of the drink, stop the steam delivery by turning the steam knob (6) clockwise 4. Remove the pitcher from the steam wand (2) and wipe the steam wand and tip immediately with a clean, damp sponge in order to remove all residue of the heated d...

  • Page 11: S1 Owner’S Manual

    S1 owner’s manual page 9 turning the steam/hot water boiler on and off 1. The s1 must be in on mode, not standby for all operations below. 2. Momentarily press the boiler button 3. The boiler lamp turns off. Neither steam nor hot water is available. Note: if you turn the s1 off then on again, or if ...

  • Page 12: S1 Owner’S Manual

    S1 owner’s manual page 10 4 alarm handling the s1 uses computerized sensors to robustly handle s1 device malfunctions. There are two types of alarms the s1 can generate: blocking alarms – these are the most serious. The s1 will not function when one of these alarms occurs non-blocking alarms – these...

  • Page 13: S1 Owner’S Manual

    S1 owner’s manual page 11 4.6 boiler automatic refill system failure (only with the boiler turned on) this is a blocking alarm which is signaled by blinking of the boiler (13) light. If the pump runs for more than 1 minute attempting to refill the boiler without the controller circuit receiving a bo...

  • Page 14: S1 Owner’S Manual

    S1 owner’s manual page 12 5 connection diagrams 5.1 electrical connection diagram.

  • Page 15: S1 Owner’S Manual

    S1 owner’s manual page 13 5.2 control board connection diagram early versions of the s1 used a jumper on the above board (jp3) to switch between 15a and 20a mode. J3 jumpered = 15a, no jumper = 20a. Newer s1 have the above board enclosed in a plastic case with a switch on the case used to change mod...

  • Page 16: S1 Owner’S Manual

    S1 owner’s manual page 14 5.5 wiring diagram definitions ev gr coffee brewing group electrovalve ev h hot water delivery electrovalve ev al automatic refill system electrovalve t1 connection on control board of the triac that feeds the boiler heating element t2 connection on control board of the tri...

  • Page 17: S1 Owner’S Manual

    S1 owner’s manual page 15 6 s1 water flow diagram the information below is provided strictly as a reference for s1 owners who are curious about the function of their s1 dual boiler design..

  • Page 18: S1 Owner’S Manual

    S1 owner’s manual page 16 7 adjustments and maintenance 7.1 external s1 surface cleaning use a damp sponge and wipe dry with a soft cloth. Alternately, window cleaner wiped off with a dry soft cloth works well. 7.2 routine group cleaning the extra pair of shower screens was not included with your s1...

  • Page 19: S1 Owner’S Manual

    S1 owner’s manual page 17 7.3 group pressure test and adjustment this adjustment and the one covered in the next section require a portafilter pressure gauge such as the one pictured below which comes mounted on a dedicated portafilter. Your s1 dealer should be able to sell you this one or you can g...

  • Page 20: S1 Owner’S Manual

    S1 owner’s manual page 18 1. Adjust the group pressure to 12.5 bar per the following instructions: a) loosen lock nut "a" using the 14mm wrench b) tighten nut "b" 1-2 turns using the 10mm wrench c) turn on pump until pressure on the pf gauge stabilizes d) repeat steps b & c until pressure reads 12.5...

  • Page 21: S1 Owner’S Manual

    S1 owner’s manual page 19 to 12 bar all dripping should stop - though it may take a minute or two for residual moisture to drip out. 5. Once you are convinced that the expansion valve is properly calibrated, readjust the rotary pump pressure by unscrewing "b" to reach your preferred pressure - norma...

  • Page 22: S1 Owner’S Manual

    S1 owner’s manual page 20 9 quick setting guide.