Lailey Abd Coates LC-07 Product Installation Manual

Manual is about: Inverter Air Source Heat Pump Split System

Summary of LC-07

  • Page 1

    Inverter air source heat pump split system lailey and coates heat pumps engineered for british homes product installation manual.

  • Page 2: Split System

    2 installation manual 2014 - riv 2 inverter air source heat pump split system.

  • Page 3: Contents

    3 installation manual 2014 - riv 2 contents general information.............................................................................................. 5 technical specification .......................................................................................... 6 installation of externa...

  • Page 4

    Installation manual 2013 riv 2 4 thank you for purchasing a lailey and coates air source heat pump. Please read this manual carefully before installation and operation. It contains important information to enable a safe and successful installation. If you have any queries please ring our technical h...

  • Page 5: General Information

    5 installation manual 2014 - riv 2 general information the lailey and coates split system consists of two major parts: the internal and external units. They are connected via refrigeration pipes and an elv, shielded, communication cable. The external units can either be wall mounted or hard-standing...

  • Page 6: Technical Specification

    Installation manual 2013 riv 2 6 indoor unit lc-07 lc-10 lc-12 lc-15 dimensions indoor unit height mm 549 549 609 609 width mm 450 450 450 450 depth mm 262 262 262 262 weight gross kg 35 36 39 40 net kg 30 31 34 35 sound pressure level dba 26 27 28 29 water flow temperature heating max ⁰ c 55 55 55 ...

  • Page 7

    7 installation manual 2014 - riv 2 installation of external unit when locating the external unit the following considerations should be taken into account: ● if wall mounting ensure that the structure is sufficiently solid to bear the weight of the unit without causing vibration. ● if floor mounted ...

  • Page 8

    8 installation manual 2014 - riv 2 when locating the internal unit the following considerations should be taken into account: ● if wall mounting ensure that the surface is flat, non‐combustible and sufficiently solid to bear the weight of the unit without causing vibration. ● provision should be mad...

  • Page 9: Wiring Instructions

    Installation manual 2013 riv 2 9 wiring instructions warnings this unit must be installed to conform with all relevant local standards and regulations by suitably qualified engineers. This unit must be earthed. Please ensure this unit has a suitable, dedicated power supply/supplies, and is not susce...

  • Page 10

    10 installation manual 2014 - riv 2 rated power input and fuse information model rated outdoor unit indoor unit combined system hz volts watts max current amps max fuse rating amps watts max current amps max fuse rating amps watts max current amps max fuse rating amps lc 07 50 220-240 3300 14 16 305...

  • Page 11

    Installation manual 2013 riv 2 11 indoor electrical connections 230 v switching only 15 hot water ‘on’ to zone valve (unsuitable for mid-position type) 14 neutral 13 heating ‘on’ to zone valve (unsuitable for mid-position type) 12 solar pump 11 10 secondary hot water pump if required 9 8 2 - port va...

  • Page 12: Plumbing Installation

    12 installation manual 2014 - riv 2 plumbing installation warnings this unit must be installed to conform with all relevant local standards and regulations by suitably qualified engineers. Installation should be capable of withstanding a maximum water pressure of 10 bar. Mid-position zone valves sho...

  • Page 13

    Installation manual 2013 riv 2 13 plumbing installation continued internal pump settings ● if used with radiators, pump should be set to auto ● if used with under floor heating, pump should be set to manual and adjusted to settings 1, 2 or 3 to achieve required flow rate as per table above. ● if a c...

  • Page 14: Refrigeration Installation.

    14 installation manual 2014 - riv 2 refrigeration installation. Warnings: this unit must be installed to conform with all relevant local standards and regulations by suitably qualified engineers. When brazing the pipe always use ofn. This unit is only suitable for r410a refrigerant. This product con...

  • Page 15

    Installation manual 2013 riv 2 15 refrigeration installation continued please note: ● refrigerant pipes can be connected to either the top or bottom of the unit. If using top connections ensure bottom connections are tight and vice-versa. ● pre‐pressure testing and commissioning, ensure service valv...

  • Page 16: Dip Switch Settings

    16 installation manual 2014 - riv 2 dip switch settings both internal and external units have a bank of pcb dip switches. These should be checked prior to initial start-up to ensure correct operation of the heat pump. Any changes to these settings should be carried out with the heat pump powered dow...

  • Page 17: Pre-Operation Checklist

    Installation manual 2013 riv 2 17 pre-operation checklist prior to initial start-up please ensure following: general : dip switches are correctly set to both external and internal units. See page 15 there is no obvious damage to the body or components of the units. Units are securely fixed to walls/...

  • Page 18: Commissioning

    18 installation manual 2014 - riv 2 commissioning after the initial installation the system needs to be commissioned, this document will explain and show how to set up and commission an air to water heat pump. Stage 1 - electrical check that the system wiring is complete and connected properly befor...

  • Page 19

    Date time and day indicator 1 timer set icon 2 system error code 3 legionella cycle active 4 volt free indicator 5 screen on / off 6 status 7 parameters 8 timers - see page 9 help 10 lcd lock 11 hot water boost 12 fault indicator 13 hot water 14 anti-freeze icon * 15 defrost indicator 16 * not requi...

  • Page 20

    20 installation manual 2014 - riv 2 time set- date: year mon day 2013 2 9 time day of hour minu sec- 9 12 9 tue cancel ok how to set up lcd controller setting the date, time and day. To access the time settings screen, touch the date, time and day indicator (1) on the controller home screen. The con...

  • Page 21

    Installation manual 2013 riv 2 21 setting the hot water temperature to set the hot water temperature, touch the ‘setting temperature’ as indicated. The controller will bleep and the screen will change to the following : enter the desired temperature and press enter. The display will revert to the ho...

  • Page 22

    22 installation manual 2014 - riv 2 setting the heating water temperature to set the heating water temperature, touch the ‘setting temperature’ as indicated. The controller will bleep and the screen will change to the following , enter the default access code 112233, then press enter. The display wi...

  • Page 23

    Installation manual 2013 riv 2 23 setting the heat pump timer from the main display home screen, touch the timer icon (9). The controller will beep and the screen will change as follows: heating hot water timer set indicator within this screen there are two display grids for days of the week, the up...

  • Page 24

    24 installation manual 2014 - riv 2 setting the timer continued individual day timer screen - heating important touch to accept settings before closing this screen touch to close the screen within the individual day timer screen there are three pairs of on/off timers. In other words the system can b...

  • Page 25

    Installation manual 2013 riv 2 25 setting the timer continued 2) once the time is set, select whether this is to start or stop the system by touching the corresponding power icon and selecting on or off. 3) the setting must then be enabled, to do this touch the enable icon and ensure that a green ti...

  • Page 26: Holiday Timer

    26 installation manual 2014 - riv 2 holiday timer to access the holiday timer touch the timer icon on the home screen. The daily timer screen will appear. Touch the holiday icon and the holiday timer screen is displayed as below. 2013 / 99 / 99 holiday off start : date time 9999 / 99 / 9999 / 99 / 9...

  • Page 27

    Installation manual 2013 riv 2 27 this guide is to provide engineers a simple understanding of potential faults and how to rectify them. Lailey and coates error / fault codes are listed in full on page 29 of this manual. High pressure fault this indicates that the heat pump system has exceeded the m...

  • Page 28

    28 installation manual 2014 - riv 2 simple trouble shooting guide - continued low pressure fault this means that the heat pump system has detected a lower pressure, set on the low pressure switch. Causes - in heating 1. Dirty outdoor coils 2. Poor airflow through the outdoor coils 3. Outdoor fan fai...

  • Page 29

    Installation manual 2013 riv 2 29 simple trouble shooting guide - continued compressor fail to start each heat pump system will have a time delay on the compressor start operation if the compressor fails to start in a set number of times in 1 hour then a fault code will appear. Causes 1. Low oil pre...

  • Page 30: Fault / Error Codes

    30 installation manual 2014 - riv 2 fault / error codes e01 communication failure between indoor and outdoor units 1- check correct specified cable has be installed 2- check connections between indoor and outdoor units see page 8 3- check the incoming power cable 4- check indoor and outdoor pcbs 5- ...

  • Page 31

    Installation manual 2013 riv 2 31 fault / error codes continued e17 tc electric heater temperature sensor failure 1 - check tc electric heater temperature sensor 2 - check indoor pcb e18 eeprom failure 1 - check eeprom 2 - check indoor pcb e19 inverter current detector fault 1 - check detector conta...

  • Page 32

    32 installation manual 2014 - riv 2 p01 high voltage protection 1 - check power supply 2 - check the incoming power cable 3 - check outdoor pcb p02 low voltage protection 1 check power supply 2 - check the incoming power cable 3 - check outdoor pcb p03 inverter module protection 1 - check inverter c...

  • Page 33

    33 installation manual 2014 - riv 2 p10 fixed speed compressor current protection 1 - check fixed speed compressor windings p11 condenser high temperature protection 1 - fan speeds 2 - check eev 3 - check t3 coil temperature sensor 4 - check outdoor pcb p12 water flow switch fs protection 1 - check ...

  • Page 34: Commissioning Sheet

    34 installation manual 2014 - riv 2 commissioning sheet this form must be completed by the commissioning engineer and sent to lailey and coates at the above address. The warranty on this unit cannot be issued until this form is received by lailey and coates. 951 yeovil road slough trading estate slo...

  • Page 35

    35 installation manual 2014 - riv 2 installation related y n y n n/a adequate service space around the outdoor unit isolating switches installed for heaters provision made for drainage of outdoor unit dip switches set on pc board if either thermostat or dhw cylinder has been installed refrigeration ...