Maximum Flow Ranges:
•
T2C-075¾"Inlet/Outlet
0to25USgpm
(0to5.7m³/hr)
•
T2C-1001"Inlet/Outlet
0to39USgpm
(0to8.9m³/hr)
•
T2C-1501
1/2"
Inlet/Outlet
0to78USgpm
(0to17.7m³/hr)
Maximum Pressure:
•
100psiat73˚F
(6.9barat38˚C)
Temperature Range:
•
32˚F-120˚F
(0˚C-49˚C)
Mesh Sizes:
•
30Mesh(600Micron)
Element(Brown)
•
60Mesh(250Micron)
Element(White)
•
100Mesh(150Micron)
Element(Gray)
•
140Mesh(105Micron)
Element(Black)
Pre-Installation Checklist
A.Selectagoodfilterlocation:
Installonthepressure(outlet)sideofanypumps
InaverticalpositionwithPurgeExitpointingdown
Awayfromextremeweatherconditionstoprotectfromfreezing
Atleast12inchesawayfromwalls,etc.sotophandlecanbetwisted
Allowenoughclearancebeneaththeunitto:
(a)attachapurgedrainhosetothePurgeExit(recommended)
(b)removetheclearbowlassembly,toallowreplacementofelementasneeded
B.Asasunnyoutdoorinstallationmightleadtoalgaegrowthinsidetheclearbowland
affecttheoperationofyourTWIST
II
CLEAN.AnoptionalSunShieldisavailable.
Safety Notes:
DespitetheeaseofinstallationandoperationoftheLAKOSTWIST
II
CLEANproduct,certain
precautionsshouldbetaken.
1. Lubricate“O”ringswithNSFapprovedsilicongreaseonly-Dow111isrecommended.
2. Donotovertightenthethreadedconnections.Donottightenmorethana1/4turnpastfinger
tight.Handtightenthebowl,donotusetools.
3. Donotusewrenchesonplasticfilterparts.Useoftoolsonfilterwillvoidwarranty.
4. Forthreadedconnections,usetheTeflon™tapesealantprovidedwithproduct.
5. Filtercomponentsthathave“O”ringsdonotrequirethreadsealant.
6. Removeclearbowlifthefilteristobeinstalledusinganysolventwelding.Thiswillprevent
solventdamagetotheclearbowl.
7. Thisfilterisdesignedforusewithwateronly.Otherchemicalsorcomponentscandamagethe
filtercomponents.Evaluateallchemicalsforproperusagewiththefilter.
8. Protectunitfromfreezing,asyouwouldwithanyotherwatersupplylines.
9. Followalllocalandstatecodes,laws,andregulationswheninstallinganyfilter.
TopHandle
RedSafetyLatch
Inlet
Outlet
FlowDirectionArrow
Mounting
Eyelets
ClearBowl
FilterElement
PurgeExit
IfforanyreasonthefilterelementdoesnotcleancompletelyduringthenormalTwisttoClean
operation,manualcleaningmaybeneeded.Inthiscase,removethebowlandcleantheelementwith
asoftbrush,brushingandrunningwateracrosselement.
Caution:
If the filter bowl is to be removed, all water flow must be shut off going to the filter.
Maintenance and Troubleshooting
Limited Warranty
TheLAKOSTWIST
II
CLEAN
iswarrantedtobefreeofmaterialorworkmanshipdefectsforatleastoneyear
fromdeliverydate.
Ifafaultdevelops,notifyus,givingacompletedescriptionoftheallegedmalfunction.Includethemodel
number(s),dateofdeliveryandoperatingconditionsofsubjectproduct(s).Wewillsubsequentlyreviewthis
informationand,atouroption,supplyyouwitheitherservicingdataorshippinginstructionandreturnedmateri-
alsauthorization.Uponprepaidreceiptofsubjectproduct(s)attheinstructeddestination,wewilltheneither
repairorreplacesuchproduct(s),atouroption,andifdeterminedtobeawarranteddefect,wewillperform
anyproducts,damagesorinjuriesresultingfrommisuse,neglect,normalexpectedwear,chemically-caused
corrosion,improperinstallationoroperationcontrarytofactoryrecommendation.Nordoesitcoverequipment
thathasbeenmodifed,tamperedwithoralteredwithoutauthorization.Nootherextendedliabilitiesarestated
orimpliedandthiswarrantyinnoeventcoversincidentalorconsequentialdamages,injuriesorcostsresulting
fromanysuchdefectiveproduct(s).
LS-866(Rev.3/11)
Inlet/Outlet
to
Purge
Port
Total
Length
TWIST
II
CLEAN
Installation Instructions for
3/4-inch Model T2C-075
1-inch Model T2C-100
1 1/2-inch Model T2C-150
Quick-Star
t Guide
Width
Dimensions
Total
Flow Rate (US gpm)
Flow Rate (m
3
/hr)
Clean Conditions
Head Loss (Bar)
Head Loss (psi)
=Recommendedflowrange
2.0
4.0
6.0
8.0
10.0
12.0
14.0
16.0
18.0
0
10
20
30
40
50
60
70
80
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
www.TWIST
II
CLEAN.com
0
1
2
3
4
5
6
7
8
9
10
T2C-075 T2C-100
T2C-150
Max Flow= 25gpm 39gpm
78gpm