Lampert M280 Operating Manual

Manual is about: TIG pulse welding device

Summary of M280

  • Page 1

    Operating manual m280 tig pulse welding device 8.

  • Page 2

    Operating manual (translation) "m280" dear customer, this operating manual is intended to familiarise you with the commissioning process and operation of your "m280”. Please read the operating instructions carefully and follow the advice given here diligently. Disruptions and operational faults will...

  • Page 3

    © lampert werktechnik gmbh 2017 2 table of contents 1 warning and information signs pg. 2 2 field of application pg. 3 3 safety requirements 3.1 general safety requirements pg. 3 3.2 personal body protection and hazards pg. 4 3.3 hazards of shielding gas cylinders pg. 4 3.4 risk of allergic reaction...

  • Page 4

    © lampert werktechnik gmbh 2017 3 2. Appropriate use (field of application) • outdoor operation is impermissible. Use this device only in dry rooms! • „m280“: the application of spot welds on steel alloys as well as various non-ferrous metals. Generally no liability is accepted for the durability of...

  • Page 5

    © lampert werktechnik gmbh 2017 4 3.2 hazards and personal body protection please also observe the relevant regulations of the respective country. Risk of injury from radiation or heat: protective gloves must be worn when welding. Uncovered areas of the skin must be protected from the uv radiation g...

  • Page 6

    © lampert werktechnik gmbh 2017 5 4.2 description of the rear of the device (fig. 2) (1) fusebox ("fuse") (2) mains switch as well as ac power socket (for connecting the mains cable) (3) connection socket for eye protection system and led illumination (4) connection socket for foot switch and absorb...

  • Page 7

    © lampert werktechnik gmbh 2017 6 4.5 inserting the electrodes into the welding handpiece: please always check that the machine is switched off, prior to exchanging the electrodes. This prevents uncontrolled triggering of the welding process. (fig. 3) (fig. 4) lightly rotate the nozzle (10) back and...

  • Page 8

    © lampert werktechnik gmbh 2017 7 5. Commissioning 5.1 description of the front-side controls (fig. 1) (21) display (22) geometry button preselect welding situation and pulse shape (23) welding power (+/-) buttons (24) settings button (25) pulse duration (+/-) buttons (26) material / metal button pr...

  • Page 9

    © lampert werktechnik gmbh 2017 8 5.3 switching on the device first, carefully open the gas tank valve. Then switch the master mains switch (2) on the rear of the housing to the “i” position – the display shows the safety prompt regarding eye protection and the operating manual. Confirm your complia...

  • Page 10

    © lampert werktechnik gmbh 2017 9 6. Selection of the welding parameters 6.1 selection of the welding parameters basic information about the effects of welding power and welding time: power: the welding power or the strength of welding energy is set with the power control (23). The size and intensit...

  • Page 11

    © lampert werktechnik gmbh 2017 10 7. Welding instructions note! Prior to welding, always check the function of the eye protection filter as described in chapter 5.5 "filter test". If the eye protection filter (shutter) fails to switch over from light to dark, then it must be immediately exchanged b...

  • Page 12

    © lampert werktechnik gmbh 2017 11 7.4 resharpening the electrodes please switch off the machine prior to exchanging the electrodes. This prevents uncontrolled triggering of the welding process. If possible, the electrodes should be sharpened with a diamond disk with fine or medium grain. The recomm...

  • Page 13

    © lampert werktechnik gmbh 2017 12 9. Technical data 9.1 technical data welding device device suitable for welding in dry rooms mains voltage mains fusing power consumption (during welding) closed-circuit voltage no-load voltage duty cycle x max. Charging time shielding gas maximum gas pressure prot...

  • Page 14

    © lampert werktechnik gmbh 2017 13 9.3 warning notices: 10. Troubleshooting 10.1 welding device fault cause remedy 1 no welding current mains master switch on, display remains off mains cable interrupted check mains cable and mains voltage device fuse blown replace device fuse with identical fuse (s...

  • Page 15

    © lampert werktechnik gmbh 2017 14 7 oxidation and rusting excessive gas pressure reduce flow rate - approx. 2 l/min is recommended 8 severe oxidation of the welding points incorrect shielding gas use inert shielding gas (argon 4.6) 9 tungsten inclusions in base material excessive pressure of the el...

  • Page 16

    © lampert werktechnik gmbh 2017 15 13. Ec – declaration of conformity please find enclosed to this shipment the separate document – declaration of conformity. Text and illustrations represent the technical status at the time of printing. Subject to change. R e v. 1 .0

  • Page 17

    Workshop news you are interested in the possibilities of use of our fine-welding devices? Or you are searching for one or another tip on working with your „m280“? Then just sign up for our newsletter on www.Lampert.Info! Visit our showroom! Our video library is showing many applications from everyda...

  • Page 18

    Born in germany. Lampert werktechnik gmbh • ettlebener straße 27 • d-97440 werneck • tel. +49.9722.9459-0 • mail@lampert.Info • www.Lampert.Info rev . 1.0