Latronics PV Edge Grid 915-GI-72 User Manual

Manual is about: Interactive Inverter

Summary of PV Edge Grid 915-GI-72

  • Page 1

    ®.

  • Page 2: Introduction

    Introduction congratulations on purchasing the latronics pv edge grid interactive inverter. Rapidly increasing interest in the solar market has resulted in the latest advancement in inverter design allowing the feeding of electrical power from photovoltaic solar panels directly into the grid. Using ...

  • Page 3

    • before opening the case ensure the dc solar input and ac grid are disconnected. • due to the risk of electric shock from lethal voltages only authorised & suitably qualified personnel are permitted to remove the cover. • safety- dc solar input and ac grid are electrically and galvanically isolated...

  • Page 4: Solar Input Configuration

    Solar input configuration panel power at 25°c module type number of panels per string number of strings solar input power 50w 12v 6 5 1500w 55w 12v 6 4 1320w 60w 12v 6 4 1440w 65w 12v 6 4 1560w 70w 12v 6 3 1260w 75w 12v 6 3 1350w 80w 12v 6 3 1440w 85w 12v 6 3 1530w 90w 12v 6 2 1080w 95w 12v 6 2 1140...

  • Page 5: Nverter Operation

    Nverter operation the inverter consists of a full bridge power stage utilising the latest generation of power mosfet's, switching a filter inductor and transformer tapping. The dc voltage of the solar input is switched at high frequency and converted to an ac sinusoidal voltage and feed into the ac ...

  • Page 6: Fault Finding

    Fault finding should the inverter appear to be malfunctioning we suggest the following to eliminate any external problems. 1. Turn the inverter “off” by disconnecting the dc solar input and then disconnecting the ac grid. 2. Reconnect the dc solar input. All lights on the inverter should come on for...

  • Page 7: Warranty Conditions

    Warranty conditions all conditions and warranties expressed or implied by statute, the common law equity trade custom or usage or otherwise howsoever are hereby expressly excluded to the maximum extent permitted by law. Where so permitted the liability of latronic sunpower pty. Ltd. For a breach of ...

  • Page 8: Technical Specifications

    Technical specifications input data recommended solar input power @25c 1500w maximum dc input current 18a maximum dc input voltage 150v maximum power point tracking range 85-140vdc automatic turn on 100vdc starting operation 10w number of modules per string 6 x 12v modules reverse polarity protectio...

  • Page 9: Declaration of Conformity

    Latronic sunpower pty ltd doc. No: m61 www.Latronics.Com.Au page 9 declaration of conformity manufacturer : latronic sunpower pty ltd abn : 97 010 707 169 address : po box 73 , moffat beach , qld 4551, australia product : 1500w pv edge dc to ac grid interactive inverter model : 912-gi-72 the product...