LCI LT3100 Operating Manual - page 2
release ‘A’ to select the digit to be changed then press and release ‘B’ to alter that digit.
01
Credit Per Coin 1
Sets the amount of credit given by a 1 pound coin or token (except L1 token). Set in HH.MM or MM.SS
(When the meter is set in single coin or Totalise + Top Up mode).
02
Credit Per Coin 2
Sets the amount of credit given by a 1€, 50c, 10p, 20p coin or L1 token. Set in HH.MM or MM.SS
(When the meter is set in single coin or Totalise + Top Up mode)
03
Total
Money
Displays the total amount of money/tokens inserted since the last factory reset.
This is a read only display and cannot be changed.
04
Total
Credit
Displays the total amount of credit given since the last factory reset.
This is a read only display and cannot be changed.
05 Pre-start
Sets the amount of time given before main session begins (entering zero disables this feature). Set in
MM.SS
06 Run-on
Sets the amount of time the meter operates after session has finished (entering zero disables this feature).
Set in MM.SS
07 Pre-end
Sets the time in which a warning is given before the session ends (entering zero disables this feature). Set in
MM.SS
08 Maximum
Credit
Sets the maximum amount of credit to be given at any one session (activated by pressing the start button
‘A’). Set in HH.MM or MM.SS depending on the configuration number (entering zero disables this
feature).
09 Totalise
Value
Sets the amount of money which needs to be inserted before any credit is given, e.g. £1:20.
10
Totalise Credit Value
Sets the amount of credit given when the correct amount of money is inserted
To Clear Credit Remaining
Remove coin box. Display will show re-settable money counter.
Press and release switch B, display will show ‘Clr’. Press ‘A’ & ‘B’ together and credit will be cleared.
Note: If already in service mode, the display must be returned to show ‘Clr’ before this feature can be used (Press and
release ‘B’ until ‘Clr’ is shown).
Credit Save
When available, the credit save is activated by the customer by pressing switch ‘B’. This will suspend the credit
countdown and turn off the output to the load. The word ‘HELd’ will be displayed. To resume the countdown and
reconnect the load, press switch ‘A’.
Override or Settings Disable Key Switch (optional)
Option A: When the override key is inserted and turned, the load will switch on and the word ‘FrEE’ will be
displayed. This action will also clear any remaining credit from the meter.
Option B: The internal settings, St.01 to St.10 can only be changed when the key switch is operated.
This prevents unauthorised access to the meter settings.