Error Messages
Error
(Er.xx)
Description
01
Opto 1 (£1) detected an object not conforming to the required parameters.
1
02
Opto 2 (20p) detected an object not conforming to the required parameters.
2
03
IIC communication error talking to the non-volatile memory.
3
04
Not used – Now replaced with ‘Sync’ message. See below.
4
05
Opto 1 validated but meter is configured as a 10p or 20p only.
5
06
Opto 2 validated but meter is configured as a £1 only.
6
07
Opto 1 validated but St.01 is zero.
7
08
Opto 2 validated but St.02 is zero.
8
09
Configuration number 1 (CFG.1), digit 2 is zero.
9
10
Meter configured in Totalise or Totalise + Top Up mode but St.09 is zero.
10
11
Totalise + Top Up on £1 only (or token) meter but St.09 has pence value.
11
12
St.09 set with odd 10p on 20p meter. E.g. set to £1.50.
12
If any of the error messages 13 – 19 are encountered please contact the LCI technical
department.
13
System Error – Mode routine entered with invalid ‘mode’ value.
14
System Error – Temp_mode routine entered with invalid ‘Temp_mode’ value.
15
System Error - ‘_Add_Mc’ entered with zero ‘Coin Value’.
16
System Error – IIC routines internal error.
17
Network circuitry not responding.
18
Unable to communicate with the RTC
19
Unable to communicate with the Card Interface
24
Incorrect meter ID.ie Wrong card for meter
25
Unknown card Type
26
Set-up card entered but meter not PS disabled.
27
Card out of date.
SynC
Formerly Er.04 – Software re-synchronising with the 50Hz signal.
4
Notes:
1
Opto 1 is the coin sensor used to validate £1 coins, L2 & L4 tokens. If the sensor detects that the coin is
the wrong size it will show the error message.
2
Opto 2 is the coin sensor used to validate 20p, 10p, €1 & 50c coins or L1 tokens. If the sensor detects that
the coin is the wrong size it will show the error message.
3
This is usually caused by a faulty component (IC4).
4
The meter has sensed that the mains supply has been switched off/on. This message is only normally
displayed for a second as the meter is switched on or off. If the message is being displayed intermittently
there may be a loose connection around the PSU PCB area of the meter.
5
Use CFG.1 – digit 1 to set the meter up for the correct coinage.
6
Use CFG.1 – digit 1 to set the meter up for the correct coinage.