    Please read this manual before installing and using appliance warning: if the information in this manual is not followed exactly, a fire or explosion may result causing prop- erty damage, personal injury or loss of life. For your safety installation and service must be per- formed by a qualified insta...

  • Page 2

    2 majestic ® fireplaces power venting system 51810 installation instructions general information and instructions for the power vent system model no. Pvs-1. Note: the pvs-1 will only work in conjunction with a vn gas valve p/n 57588 or vp gas valve p/n 57587. 1. This power vent system must be instal...

  • Page 3

    3 majestic ® fireplaces power venting system 51810 3. Vent system termination before installing power venter, determine location of vent system termination. 4. Location of the fan to keep the noise level to a minimum, the fan should be located as far from the appliance as possible. A storage cupboar...

  • Page 4

    4 majestic ® fireplaces power venting system 51810 v v v v v v v x x x d e b b b c b m b a j k f l vent termination air supply inlet area where terminal is not permitted h i v b cfm145a dv termin location 5/01/01 rev. 12/05/01 sta inside corne...

  • Page 5

    5 majestic ® fireplaces power venting system 51810 fp1417 powervent system front view 11/24/03 djt 4” (102 mm) insu- lated flue liner sound reducer sheet metal screws fireplace top fireplace fp1417 fig. 1 secure sound reducer to fireplace top with four (4) sheet metal screws. Installation restriction...

  • Page 6

    6 majestic ® fireplaces power venting system 51810 fp1421 min. Vertical rise 11/25/03 djt 18” (457mm) minimum fp1421 fig. 5 an 18” (457mm) minimum vertical rise is necessary before a 90° elbow. Fp1422 pipe transitions 11/25/03 djt negative pressure power venter positive pressure all seams on the pos...

  • Page 7

    7 majestic ® fireplaces power venting system 51810 6. Measure distance between fireplace’s flue outlet (top of sound reducer) and fan inlet. Cut flexible duct and insulate with insulation sleeve sections using noise cone for ease of mounting. Please note that wherever possible use continuous length pip...

  • Page 8

    8 majestic ® fireplaces power venting system 51810 operation and checking the draft 1. Insofar as is practical, close all doors, windows and air inlets to the building. Turn on all exhaust fans (range hood, bathroom exhaust, etc.) so they will operate at maximum speed. 2. Place appliance into operat...

  • Page 9

    9 majestic ® fireplaces power venting system 51810 power venter part list mounting bracket 1” 50543 mounting bracket 6” 49552 hose clamp 51875 motor assembly, power vent 51867 switch, wall 51842 vibration insulator 50545 plate wall switch 51843 pressure switch 52921 timer relay/post purge 52901 tran...