  • Page 1

    N n n v v v f f f - - - 2 2 2 0 0 0 0 0 0 s s s e e e / / / p p p d d d k k k i i i t t t e e e t t t h h h e e e r r r n n n e e e t t t e e e x x x t t t e e e n n n d d d e e e r r r w w w i i i t t t h h h r r r e e e m m m o o o t t t e e e p p p o o o w w w e e e r r r u u u s s s e e e r r r ...

  • Page 2

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 1 copyright copyright © 2011 by national enhance technology corp. All rights reserved. Trademarks netsys is a trademark of national enhance technology corp. Other brand and product names are registered trademarks or trademarks of their...

  • Page 3

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 2 foreword nvf-200se system delivers power and ip connectivity at distances up to 1km (3,280ft) using existing or new copper twisted pair phone cable. These innovative transmission techniques result in power feeding and data over a sin...

  • Page 4

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 3 safety warnings for your safety, be sure to read and follow all warning notices and instructions before using the device. Do not open the device or unit. Opening or removing covers can expose you to dangerous high voltage points or o...

  • Page 5

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 4 table of contents copyright ........................................................................................................................................................ 1 safety warnings .....................................

  • Page 6

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 5 3.1 nvf-200se / nvf-200pd detailed view .....................................................................................................................................13 3.2 front panel.............................................

  • Page 7

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 6 warranty ....................................................................................................................................................... 37 chinese sj/t 11364-2006.................................................

  • Page 8: Chapter 1.

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 7 chapter 1. Unpacking information 1.1 check list carefully unpack the package and check its contents against the checklist. Package contents: • 1 x nvf-200se + 1 x nvf-200pd • 2 x 48v / 0.4a power adapter • 2 x ac to dc power cord • 2...

  • Page 9: Chapter 2.

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 8 chapter 2. Installing the bridge 2.1 hardware installation this chapter describes how to install the bridge and establishes network connections. You may install the bridge on any level surface (e.G. A table or shelf). However, please...

  • Page 10

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 9 2.3 general rules before making any connections to the bridge, please note the following rules: • ethernet port (rj45) all network connections to the bridge ethernet port must be made using category 5 utp for 100mbps, category 3, 4 u...

  • Page 11

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 10 figure2.1: nvf-200se/pd line ports straight connection figure 2.2: nvf-200se/pd line ports crossover connection.

  • Page 12

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 11 2.5 connecting the line / ethernet ports 1. The bridge’s line port supports max distance of 1km at 5m/5m or max speed of 25m symmetrically with distance up to 500m for data service across existing phone wiring. It is easy-to-use whi...

  • Page 13

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 12 notes: 1. Be sure each twisted-pair cable (rj-45) does not exceed 100 meters (328 feet). 2. Line port must use 22 ~ 26 gauge phone wiring, we do not recommend 28 gauge or above. 3. We advise using category 3, 4, 5 cables for cable b...

  • Page 14: Chapter 3.

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 13 chapter 3. Hardware description this section describes the important parts of the bridge. It features the front panel and rear connectors. 3.1 nvf-200se / nvf-200pd detailed view figure 3.1: nvf-200se detailed view figure 3.2: nvf-2...

  • Page 15

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 14 3.2 front panel the figure shows the front panel of both nvf-200se and nvf-200pd. ( figure 3.3 ) figure 3.3: front panel of nvf-200se/pd at a quick glance of the front panel, it is easy to tell if the bridge has power, if it has sig...

  • Page 16

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 15 3.3 front indicators the bridge has six led indicators. The following table shows the description. ( table 3-2 ) table 3-2: led indicators description and operation leds color status descriptions on the system power is normal and fu...

  • Page 17

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 16 3.4 rear panel the following figure shows the rear connectors. ( figure 3.4 ) figure 3.4: rear connectors of nvf-200se/pd respectively at quick glance, you can see the dip switch setting at default mode, where it is in auto-speed an...

  • Page 18

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 17 speed mode config: to config the data speed to 25mbps: pin 2 must be switch on while pin 1 is off. To config the data speed to 15mbps: pin 1 must be switch on while pin 2 is off. To config the data speed to 5mbps: both pin 1 and pin...

  • Page 19: Chapter 4.

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 18 chapter 4. About performance 4.1 auto and manual data speed selector description: nvf-200se is a vdsl solution which supports real plug & play and can do auto and manual selection of the data speed, the setting of the data speed dep...

  • Page 20

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 19 4.2 distance & power relational tables the table describes connect to a loading device of the output voltage of 12v, calculate the distance and the relationship between power consumption.( table 4-1 ) table 4-1: distance & power rel...

  • Page 21: Appendix A:

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 20 appendix a: cable requirements a.1 ethernet cable a cat. 3, 4 or 5 twisted pair cable is typically used to connect the ethernet device to the bridge. A 10base-t cable often consists of four pairs of wires, two of which are used for ...

  • Page 22

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 21 figure a-2 pin assignments and wiring for an rj-45 straight-through cable figure a-3 pin assignments and wiring for an rj-45 crossover cable.

  • Page 23

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 22 a.2 telephone wire standard telephone wire of any gauge or type-flat, twisted or quad is used to connect the bridge to the telephone network. A telephone cable typically consists of three pairs of wires, one of which is used for tra...

  • Page 24: Appendix B:

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 23 appendix b: ieee 802.3af pse and powered device power classifications table b-1: ieee 802.3af pse and powered device power classifications class usage minimum power levels output at the pse maximum power levels at the powered device...

  • Page 25: Appendix C:

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 24 appendix c: product specification key features & benefits • supports plug & play (pnp) • compliant with ieee802.3 10base-t, ieee802.3u, 100base-tx and ieee802.3af ethernet pd class 0, 1, 2, or 3 standards • compliant with etsi, itu ...

  • Page 26

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 25 product specifications standard compliant: ieee802.3 10base-t standard ieee802.3u 100base-tx standard ieee 802.3af poe standard itu-g993.1 vdsl standard emc compliant: ce,fcc,vcci safety compliant: en60950 environmental protection c...

  • Page 27

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 26 led indication: power/remote power for system link/active status for ethernet port remote power link good for pov power link good for poe line speed for line port vdsl frequency spectrum: nvf-200se transmitter: 900 khz ~ 3.9mhz rece...

  • Page 28

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 27 humidity: 10% to 90% (non-condensing) dimensions: nvf-200se: 146mm x 97mm x 33mm (5.75" x 3.82" x 1.30”) nvf-200pd: 169mm x 106mm x 33mm (6.65" x 4.17" x 1.30”).

  • Page 29: Appendix D:

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 28 appendix d: troubleshooting diagnosing the bridge’s indicators the bridge can be easily monitored through its comprehensive panel indicators. These indicators assist the network manager in identifying problems that hub may encounter...

  • Page 30

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 29 2.6 make sure that the phone wire must be connected between nvf-200se and nvf-200pd first, when both are to be power on. 2.7 replace the defective bridge or cable if necessary. 3. Symptom: bridge speed link cannot be established. Ca...

  • Page 31

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 30 5. Symptom: nvf-200pd poe led does not light up. Cause: the networking device connecting to the nvf-200pd does not follow ieee802.3af poe standards. Solution: make sure that the networking device must conform to ieee802.3af poe stan...

  • Page 32

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 31 8. Question: how can i establish the nvf-200pov connection. Answer: when the equipment you want connect to nvf-200pd, please make sure the networking device has built-in power splitter(pd) function, if yes, please connect it directl...

  • Page 33

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 32 system diagnostics power and cooling problems if the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or internal power supply as explained in the previous...

  • Page 34

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 33 if problems occur after altering the network configuration, restore the original connections, and try to track the problem down by implementing the new changes, one step at a time. Ensure that cable distances and other physical aspe...

  • Page 35: Appendix E:

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 34 appendix e: compliance and safety information fcc radio frequency interference statement this equipment has been tested and found to comply with the limits for a computing device, pursuant to part 15 of fcc rules. These limits are d...

  • Page 36

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 35 proper functioning of your equipment. If they do, you will be notified in advance in order for you to make necessary modifications to maintain uninterrupted service. This equipment may not be used on coin service provided by the tel...

  • Page 37

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 36 fcc warning this equipment has been tested to comply with the limits for a class a digital device, pursuant to part 15 of the fcc rules. These limits are designed to provide reasonable protection against harmful interference when th...

  • Page 38

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 37 warranty the original owner that the product delivered in this package will be free from defects in material and workmanship for one year parts after purchase. There will be a minimal charge to replace consumable components, such as...

  • Page 39

    Nvf-200se/pd power over vdsl master/slave user’s manual ver. B.4 38 chinese sj/t 11364-2006 有 毒 有 害 物 质 或 元 素 部件名称 铅 (pb) 汞 (hg) 镉 (cd) 六价铬 [cr(vi)] 多溴联苯 (pbb) 多溴二苯醚 (pbde) 结构壳体 ○ ○ ○ ○ ○ ○ 电路组 ○ ○ ○ ○ ○ ○ 电源供应器 ○ ○ ○ ○ ○ ○ 线材 ○ ○ ○ ○ ○ ○ 包装及配件 ○ ○ ○ ○ ○ ○ ○:表示该有毒物质在该部件所有均质材料中的含量均在 sj/t 11364/2006 标...