NCI 6702 User manual - Device

Other manuals for 6702: User Manual, User manual
Manual is about: Point-of-Sale Interface Scales 6700 Family

Summary of 6702

  • Page 1

    User’s manual model 6700 family model 6720 model 6702 model 6710 point-of-sale interface scales.

  • Page 2: Specifications At Any Time.

    Model 6700 family user’s manual 2 risk of electrical shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. Weigh-tronix reserves the right to change specifications at any time. Caution 03/12/02 6700_u.P65 pn 7424-14787e e1 printed in usa.

  • Page 3: Table of Contents

    Model 6700 family user’s manual 3 specifications ...................................................... 4 initial setup ......................................................... 7 operation ............................................................ 8 menu structure ...................................

  • Page 4: Specifications

    Model 6700 family user’s manual 4 specifications description capacity/resolution agency certificates of conformance the nci 6700 models are digital electronic bench scales specifically designed for point-of-sale applications and are “legal-for-trade.” the scales are easily interfaced with a cash reg...

  • Page 5: Dimensions

    Model 6700 family user’s manual 5 model 6702: 10.4 x 6.4 x 2.5 model 6710: 10.4 x 10.4 x 2.5 model 6720: 14.1 x 12.6 x 4.1 model 4740: 14.0 x 10.0 ul/csa approved power supply with 6’ line cord 6702/6710: wallmount 6720: in-line mounted below scale input: 120 vac +10%-15%, standard 3 wire w/ground o...

  • Page 6: Under Capacity Limits

    Model 6700 family user’s manual 6 under capacity limits over capacity limits sealing internal counts dynamic response communications under capacity indication will be given with dashes appearing on the bottom line of the display whenever the display is below the initial zero value. Over capacity ind...

  • Page 7: Initial Setup

    Model 6700 family user’s manual 7 initial setup 1. Remove contents of the shipping container. 2. Inspect the scale for evidence of shipping damage. Immediately report any damage to the shipper. 1. Mount the scale on a stable, level surface that is free from air currents and vibration. Be sure the sc...

  • Page 8: Operation

    Model 6700 family user’s manual 8 operation power up test sequence if ram or rom error is reported, you must press the test key to acknowledge the condition. See “error codes” section. 3. Loosen the collets or jam nuts on the leveling feet. Level the scale by using the level bubble under the scale p...

  • Page 9: 0.00Is Displayed.

    Model 6700 family user’s manual 9 1. With the scale powered on, make sure the scale platter is empty and the display is at zero. If it is not, press the zero key… 0.00is displayed. 2. Place an item to be weighed on the scale platter… the scale will display the gross weight. 3. Remove the item from t...

  • Page 10: Figure 2

    Model 6700 family user’s manual 10 there are three modes available to you with switch 1 in the menumode or openposition. They are as follows: diag (diagnostic mode) – to test areas of the scale’s function cal (calibration mode) – to calibrate the scale conf (configuration mode) – to configure the sc...

  • Page 11: Figure 3

    Model 6700 family user’s manual 11 figure 3 menu structure.

  • Page 12: Alternate

    Model 6700 family user’s manual 12 alternate calibration points table 1 alternative calibration points baud rate and parity options table 2 baud rate and parity options the nci 6700 bench scales allow calibration using less than full capacity weights. See table 1 for alternative weights that can be ...

  • Page 13: Ln Fr

    Model 6700 family user’s manual 13 the diagnostic (diag) mode menu allows testing of specific areas of the scale’s function and viewing current configuration settings. This includes the following: display (disp) – shows the version and revision of the software, followed by a display segment test. Ra...

  • Page 14: Diag Menu.

    Model 6700 family user’s manual 14 if you encounter any failure in these tests, contact your local weigh-tronix dealer. Press the zero key to scroll through lists of selections. Press the test key to make a selection. To skip a test, press the zero key to scroll to the next test. Follow these steps ...

  • Page 15: 13. Press The Zero Key…

    Model 6700 family user’s manual 15 9. With a loopback connector in place, press the test key to perform the i/o test… pass or fail is displayed briefly, then i/o.This test is only valid on 9-pin or 15-pin models configured as “rs” units. 10. Press the zero key . . . Div-ais displayed. This stands fo...

  • Page 16: 18. Press The Zero Key…

    Model 6700 family user’s manual 16 18. Press the zero key… filt is displayed. This stands for filter- ing. 19. Press the test key… the current filter setting, fast or slo, is displayed. 18. Press the zero key… prot is displayed. This stands for protocol. 19. Press the test key… the current serial pr...

  • Page 17: Nci – Nci Standard

    Model 6700 family user’s manual 17 the configuration (conf) mode menu allows scale configuration for your specific application needs. The items you can configure are as follows: filtering (filt) – choose between fast and slo filtering. Slo should be chosen in areas susceptible to vibration. Choose f...

  • Page 18: Press The Test Key…

    Model 6700 family user’s manual 18 2. Press the test key… filt is displayed. 3. Press the test key… the current setting, fast or slo, is displayed. 4. Use the zero key to toggle between the two choices. Press the test key when the choice you want is displayed. The choice is accepted and the display ...

  • Page 19: Press The Test Key…

    Model 6700 family user’s manual 19 the calibration (cal) mode menu lets you calibrate your scale. The items in the calibration menu are as follows: pounds/kilograms (lbs or 1000 gr) – selects the unit of measure of your calibration test weights (lb or kg). Capacity (9.995, 15.005, 30.01, 60.02 etc.)...

  • Page 20: Press The Test Key. . .

    Model 6700 family user’s manual 20 5. When the desired capacity is displayed, press the test key. . . That choice is accepted andload 0is displayed. 6. Clear all weight from the scale platter and press the test key… after a brief wait load xxis displayed. Alternate calibration points can be chosen u...

  • Page 21: Review/test Scale Settings

    Model 6700 family user’s manual 21 the test key located on the front panel lets you perform some basic system diagnostics, as well as review the current system settings without having to access switches inside the scale. Review/test scale settings important: if you press and release the test key, th...

  • Page 22: Communication

    Model 6700 family user’s manual 22 communication communications enabled serial data transmission modem control lines will not be supported for rs-232 4-bit parallel ecr interface the 6700 is capable of interfacing with an eia standard rs-232, full duplex, asynchronous, smart device, or 4-bit paralle...

  • Page 23: Pin

    Model 6700 family user’s manual 23 the scale end of the interface cable plug is a da 15 pin socket. The other end is as required by your application. Below is a pin and signal list for the da 15 pin interface cable. Pin rs-232 4-bit parallel 1 rxd data 1 2 txd data 2 3 sig gnd sig gnd 4 data 4 data ...

  • Page 24: Error Codes

    Model 6700 family user’s manual 24 error codes the 9-pin version of the 6700 has de type female connector accessible at the rear of the unit. The functional pinout of this connector is compatible with a standard pc with a pass- through cable. De-9 female scale de-9 male host pin name direction pin n...

  • Page 25: No Power (Display Is Blank)

    Model 6700 family user’s manual 25 perform the following steps in the order pre- sented until the described problem is corrected. No power (display is blank) 1. Check that the primary side of the cord is plugged into the ac outlet, and the second- ary side is properly connected to the power jack on ...

  • Page 26: Press The Zero Key.

    Model 6700 family user’s manual 26 display shows unrecognized characters 1. Check software prom for proper insertion. 2. Check display cables for the proper connec- tion. 3. Replace prom. 4. Replace the display board. 5. Replace the main board. Display shows under “_ _ _ _” dashes (indicates that th...

  • Page 27: Device

    Model 6700 family user’s manual 27 scale is not transmitting data to the host device 1. Check cable connection at both the rear of the scale and the host device. 2. Check communication setting and baud rate on both scale and software. 3. Perform i/o loopback test. 4. Replace the cable. 5. Replace th...

  • Page 28

    Model 6700 family user’s manual 28 notes.

  • Page 29

    Model 6700 family user’s manual 29.

  • Page 30

    Model 6700 family user’s manual 30

  • Page 31

    Model 6700 family user’s manual 31.

  • Page 32

    1000 armstrong drive fairmont, mn 56031 telephone: 507-238-4461 facsimile: 507-238-4195 e-mail: service@wt-nci.Com www.Wt-nci.Com.