Oerlikon THERMOVAC TM101 Operating Instructions Manual - 3  Installation

Manual is about: 230081V01;230082V01

Summary of THERMOVAC TM101

  • Page 1

    Thermovac tm101 operating instructions 300306186_002_a2 part-no.: 230081v01 (tm101 incl. 9v battery) part-no.: 230082v01 (accessory set).

  • Page 2: Content

    2 300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum content 1 safety instructions ......................................................................... 3 2 the tm 101 ...................................................................................... 4 2.1 for orientation ..................

  • Page 3: 1  Safety Instructions

    300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 3 1 safety instructions read and follow the instructions of this manual inform yourself regarding hazards, which can be caused by the product or arise in your system comply with all safety instructions and regulations for accident prevention che...

  • Page 4: 2  The Tm 101

    4 300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 2 the tm 101 2.1 for orientation these operating instructions describe installation and operation of products with part number 230081v01 (for serial no. Higher than 2010-700) and 230082v01. The article number can be found on the product's type...

  • Page 5

    300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 5 measurement principle the tm 101 is equipped with an internal piezo-resistive sensor for measuring rough vacuum. Under the influence of pressure a thin diaphragm is bent, on it's back a resistor-bridge is applied. The bending forces the measur...

  • Page 6

    6 300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum operation mode renew battery pressure display refresh: 1.0s 1200 – 5.0-4 mbar "ur": pressure unit 2.4 overview usb interface mode key cover of battery compartment small flange dn16 iso kf connection f. Mains adapter 15v=, 50ma jack 2,5mm (+ on...

  • Page 7: 3  Installation

    300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 7 3 installation 3.1 installation notes unauthorized modifications or conversions of the instrument are not allowed! Installation location: indoor for not fully air conditioned open buildings and operation rooms: temperature: +5°c ... +50°c rel....

  • Page 8

    8 300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 3.3 electrical connection battery operation before operating the tm 101 a suitable battery or rechargeable battery must be inserted. For this purpose pull the battery cover on the back of the unit downwards and insert the battery as shown on t...

  • Page 9

    300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 9 the sockets for the plug-in power supply and usb are located behind a protective rubber lid. To access the sockets please carefully open the lid and pull it out slightly! Operation with external mains adapter alternatively to battery operation...

  • Page 10: 4  Operation

    10 300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 4 operation 4.1 short time pressure display / auto-off mode switch-on the gauge by pressing the mode-key: the actual pressure is displayed. After 20 seconds the vacuum meter is automatically switched off. 4.2 continuous pressure display / con...

  • Page 11

    300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 11 mode mode 1) short-term operation (auto-off mode) press mode-key: the actual pressure is displayed. After 20 seconds the vacuum meter is auto- matically switched off. 2) stored maximum pressure: press mode-key again: after two more seconds th...

  • Page 12

    12 300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 5) data logger mode: the actual pressure is displayed. The data memory is deleted. The tm 101 is in data logger mode and from now on stores new extremal pressure values and –if applicable- up to 2000 mea- surements with the preset logging rat...

  • Page 13

    300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 13 the tm 101 is switched into pc mode as soon as a cable connection with a free pc usb port is established: the tm 101 is now ready for bidirectional data transmission. When the tm 101 is switched into pc mode, actual pressure display as well a...

  • Page 14: 5  Configuration

    14 300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 5 configuration to switch the tm 101 into configuration mode: with the instrument switched-off hold the mode-key pressed for approx. 5 seconds, until the display shows ‘’rate’’. 5.1 logging rate to set the logging rate of your tm 101 and ther...

  • Page 15

    300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 15 via usb interface the user can set logging rates between 1,0s and 6000s arbitrarily! The logging rate which was set last this way is also available for choice in the tm 101 display and shown after "trig". Without further keystroke the vacuum ...

  • Page 16

    16 300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum after 5s without further keystroke adjustment is performed: during the adjustment procedure the display shows "cali". Afterwards the unit switches to auto-off mode. Adjustment on zero pressure for adjustment on zero pressure the actual pressu...

  • Page 17

    300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 17 after 5 more seconds the current unit setting is displayed: using the mode-key you can now select "mbar", "torr", "mtorr" or "hpa". Without further keystroke, the unit switches to auto-off mode after approx. 5 seconds. The last settings are s...

  • Page 18

    18 300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 5.5 gas correction factor the output signal of the pirani sensor inside your tm 101 and therefore the pressure reading of the gauge below 15 mbar depend on type and composition of the gas being measured. The device is adjusted for n 2 and dry...

  • Page 19

    300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 19 6 maintenance and service danger of possibly contaminated parts! Contaminated parts can cause personal injuries. Inform yourself regarding possible contamination before you start working. Be sure to follow the relevant instructions and take c...

  • Page 20: 7  Technical Data

    20 300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 7 technical data measurement principle piezoresistive + heat conduction pirani (gas type dependent) materials with vacuum contact stainl. Steel 1.4307, gold, nickel, tungsten, glass, viton® measuring range 1200 - 5,0x10 -4 mbar (900 - 5,0x10 ...

  • Page 21

    300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 21 declaration of conformity.

  • Page 22: Notes

    22 300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum notes __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ ...

  • Page 23: Notes

    300306186_002_a2 - 12/2010 - © oerlikon leybold vacuum 23 notes __________________________________________________________ __________________________________________________________ __________________________________________________________ __________________________________________________________ ...

  • Page 24

    Sales and service germany oerlikon leybold vacuum gmbh bonner strasse 498 d-50968 cologne phone: +49-(0)221-347 1234 fax: +49-(0)221-347 1245 sales.Vacuum@oerlikon.Com www.Oerlikon.Com oerlikon leybold vacuum gmbh sales area north/northeast branch office berlin industriestrasse 10b d-12099 berlin ph...