OK. OAC 2221 User Manual

Summary of OAC 2221

  • Page 1

    Oac 2221 mobiles klimagerÄt // portable air conditioner de gebrauchsanweisung 3 en user manual 18 im_oac2221_161201_v04 www.Ok-online.Com imtron gmbh wankelstraße 5 85046 ingolstadt germany www.Imtron.Eu 9 10 on/off short cut timer on timer off mode fan temp sleep led 20 fan set temp. Auto cool dry ...

  • Page 2

    1 n 1 1 2 q o n 2 2 min 30 cm max 120 cm 3 1 1 2 2 r o n 4 5 on/off short cut timer on timer off mode fan temp sleep led 20 fan set temp. Auto cool dry heat fan auto timer on timer off 6 7 on/off short cut timer on timer off mode fan temp sleep led 20 fan set temp. Auto cool dry heat fan auto timer ...

  • Page 3

    3 de herzlichen glückwunsch! Vielen dank, dass sie sich für ein produkt von ok. Entschieden haben. Bitte lesen sie diese anleitung sorgfältig durch und bewahren sie sie für späteren gebrauch auf. Wichtige sicherheitsanweisungen. Bitte aufmerksam durchlesen und für spÄteren gebrauch aufbewahren. 1. W...

  • Page 4

    4 de 13. Verwenden sie keine aerosol-sprühdosen in der nähe des produkts. 14. Das produkt ist nur für den gebrauch in innenräumen bestimmt. 15. Positionieren sie das produkt so, dass der netzstecker zugänglich ist. 16. Beachten sie die minimale und maximale umgebungstempe- ratur für den betrieb in d...

  • Page 5

    5 de 26. Nehmen sie das produkt nicht mit feuchten händen, oder auf nassem untergrund stehend in betrieb. Fassen sie den netzstecker nie mit nassen oder feuchten händen an. 27. Dieses produkt entspricht der schutzklasse i und muss daher an den schutzleiter angeschlossen werden. 28. Nur in trockenen ...

  • Page 6

    6 de beschreibung a. Bedienfeld 1. Anzeige 2. Kontrollleuchten temperatureinheit °f / °c 3. Kontrollleuchten lüftergeschwindigkeit high / low 4. Wahltaste lüftergeschwindigkeit fan 5. Zeitschaltuhr-einstelltaste timer mit kontrollleuchten 6. Taste erhöhen 7. Ein-/standby-taste mit kontrollleuchte 8....

  • Page 7

    7 de installation aufstellort beachten sie folgende punkte bei der wahl des installationsorts: • beachten sie alle sicherheitshinweise! • halten sie einen umgebungsabstand in jede richtung von 30 cm und 100 cm zu anderen elektroprodukten ein. • halten sie einen umgebungsabstand von 50 cm rund um den...

  • Page 8

    8 de funktionen bedienfeld fernbedienung funktion on/off ein oder in standby schalten temp wert erhöhen temp wert verringern mode modus auswählen fan lüftergeschwindigkeit einstellen sleep schlafmodus ein-/ausschalten timer off timer on einstellung der zeitschaltuhr ein/standby - led anzeige und ind...

  • Page 9

    9 de kontrollleuchten bedienfeld fernbedienung funktion auto produkt im automatikmodus cool produkt im kühlmodus dry produkt im entfeuchtungsmodus - heat ohne funktion fan produkt im lüftermodus fan fan lüftergeschwindigkeit hoch fan lüftergeschwindigkeit niedrig - fan auto lüftergeschwindigkeit aut...

  • Page 10

    10 de modi modus anwendung automatikmodus • das produkt wählt den geeigneten modus, um die eingestellte temperatur zu erreichen • die lüftergeschwindigkeit wird automatisch eingestellt • die temperatur kann manuell eingestellt werden auto kühlmodus • kühlt die raumtemperatur herunter • der kühl-komp...

  • Page 11

    11 de abb. 10 zeitschaltuhr einstellen die zeitschaltuhr schaltet das produkt ein oder in standby, nachdem eine wählbare zeit verstrichen ist. Beim einschalten verwendet das produkt den / die letzten verwendeten modus und einstellung. Die eingestellte dauer wird umgehend nach der eingabe heruntergez...

  • Page 12

    12 de abb. 11 entwÄssern wasser wird ausschließlich während des automatik- auto, kühl- und entfeuchtungs- modus angesammelt. Während des entfeuchtungsmodus wird wasser unverzüglich durch den oberen ablauf abgeleitet und der entwässerungsschlauch muss dauerhaft angeschlossen sein. Das wasser wird dur...

  • Page 13

    13 de reinigung und pflege abb. 12 schalten sie das produkt in standby und ziehen sie den netzstecker, um es von der stromversorgung zu trennen. Hinweis: reinigen sie das produkt alle zwei wochen. Reinigen sie die äußeren oberflächen des produktes mit einem feuchten lappen und neutralem reinigungsmi...

  • Page 14

    14 de fehlerbehebung sollte es während des betriebs zu störungen kommen, beachten sie nachfolgende tabelle. Sollten die probleme wie unter behebung angegeben nicht abgestellt werden können, wenden sie sich an ihren händler. Problem mögliche ursache behebung produkt startet nicht nicht an die stromve...

  • Page 15: 2,3

    15 de technische daten stromversorgung : 220 - 240 v~ 50 hz leistung : 1300 w schutzklasse : i kühlleistung : 2345 w (8000 btu/h) für räume bis max 80 m³ kühlmittel : r410a / 0,270 kg informationsanforderungen produktdatenblatt lokale klimaanlagen y ij a ie ia e eer a a b c d a a 2,3 kw 2,6 eer 65 d...

  • Page 16

    16 de oac 2221 bezeichnung symbol wert einheit schallleistungspegel l wa 65 db treibhauspotenzial * gwp 2088 kg co 2 eq. Nenn-leistung im kühlbetrieb p rated im kühlbetrieb 2,3 kw nenn-leistung im heizbetrieb p rated im heizbetrieb n/a kw nenn-leistungsaufnahme im kühlbetrieb p eer 0,9 kw nenn-leist...

  • Page 17

    17 de schaltplan cn6 fan cn10 up green(or y/g) white(or blue) black(or brown) power sw1 cn4 m ~ brown blue cn1 display board p03p04 p01p02 cn3 y/g el su ry1 motor ~ black m y/g red cap compressor black red m ~ y/g blue blue cn6 fan up green(or y/g) white(or blue) black(or brown) power sw1 cn4 m ~ br...

  • Page 18

    18 en congratulations thanks for your purchase of an ok. Product. Please read this manual carefully and keep it for future reference. Important safety instructions. Read carefully and keep for future reference. 1. Important safety instructions! Read carefully and keep for future reference! Pay parti...

  • Page 19

    19 en 16. Observe the minimal and maximal ambient temperature for operation stated in the technical data. 17. Do not attempt to modify the product in any way. Only use attachments and accessories recommended by the manufacturer. 18. Ensure the rated voltage shown on the rating label corresponds with...

  • Page 20

    20 en 32. Handle leaking batteries with proper protection and dispose them of accordingly. Prevent battery acid from coming into contact with skin and eyes. If you do get battery acid in your eyes or mouth, flush them thoroughly with lots of water and seek medical advice immediately. If battery acid...

  • Page 21

    21 en components a. Control panel 1. Display 2. Unit indicator °f / °c 3. Fan speed indicators high / low 4. Fan speed button fan 5. Timer program button timer with indicators 6. Increase button 7. On/standby button with indicator 8. Decrease button 9. Sleep mode button sleep with indicator 10. Mode...

  • Page 22

    22 en installation placement when choosing an installation place, consider following points: • observe all safety warnings! • ensure the minimum surrounding distance in every direction of 30 cm and 100 cm to other electrical products. • keep a surrounding distance of minimum 50 cm around the outside...

  • Page 23

    23 en operation fig. 5 switching on/off the product can only be switched on or into standby. Unplug in order to switch off. Press the on/standby button or on/off button to switch the product on or into standby. Notes: • after a power break or when the product is switched into standby and on again in...

  • Page 24

    24 en functions control panel remote control function on/off switch on or into standby temp increase value temp decrease value mode toggle through modes fan toggle through fan speeds sleep switch sleep mode on/off timer off timer on adjustment of timer on and standby time - led display and indicator...

  • Page 25

    25 en indicators control panel remote control function auto product in automatic mode cool product in cooling mode dry product in dehumidifying mode - heat function not provided fan product in fan mode fan fan fan speed set to high fan fan speed set to low - fan auto fan speed set to auto timer on a...

  • Page 26

    26 en modes mode application automatic mode • products selects the suitable mode to achieve the set temperature • fan speed is controlled automatically • temperature can be adjusted auto cooling mode • cools down the room temperature • the refrigerating compressor runs and stops in order to maintain...

  • Page 27

    27 en fig. 10 setting the timer the timer switches the product on or into standby when a user-defined time has elapsed. When switching on, the last mode and setting will be used. The set durations will be counted down immediately after the input without correlation to the contrary time setting. 1. P...

  • Page 28

    28 en cleaning & care fig. 12 switch the product into standby and unplug in order to disconnect from the mains. Note: clean the product every two weeks. Clean the outer surfaces of the product with a damp cloth soaked in neutral detergent. Dry it with a lint-free cloth. Do not use chemical, alkaline...

  • Page 29

    29 en troubleshooting if there are any problems during operation, please refer to the following table. If problems cannot be solved as indicated under solution, please contact your manufacturer. Problem possible cause solution product does not start not connected to power supply connect to power sup...

  • Page 30: 2,3

    30 en technical data power supply : 220 - 240 v~ 50 hz power : 1300 w protection class : i cooling capacity : 2345 w (8000 btu/h) suitable for rooms up to max 60 m³ refrigerant : r410a / 0.270 kg information requirements product fiche local air conditioners y ij a ie ia e eer a a b c d a a 2,3 kw 2,...

  • Page 31

    31 en oac 2221 description symbol value unit sound power level l wa 65 db global warming potential * gwp 2088 kg co 2 eq. Rated capacity for cooling p rated for cooling 2.3 kw rated capacity for heating p rated for heating n/a kw rated power input for cooling p eer 0.9 kw rated power input for heati...

  • Page 32

    32 en wiring diagram cn6 fan cn10 up green(or y/g) white(or blue) black(or brown) power sw1 cn4 m ~ brown blue cn1 display board p03p04 p01p02 cn3 y/g el su ry1 motor ~ black m y/g red cap compressor black red m ~ y/g blue blue cn6 fan up green(or y/g) white(or blue) black(or brown) power sw1 cn4 m ...