PABX 208AC Instruction Manual - page 20
Chapter Three System Program
16
3.4 System Data Default Set
Format : * 6 000 #
Description: This system can initialize system-programmed data.
All data can be restored to default setting except data of the follow 3 parameters.
1. Outside line connection assignment ( CO parameters);
2. Extension number parameters;
3. Call bill memory.
Default Values
Outside (CO ) Line Caller ID signal
Adapt with FSK, DTMF
Trunk group
Not set
Extension, CO Line Group
0
Extension outside call class
Not set
Head-digits assignment
Monitor voice record
Call duration time limit
Hookswitch flash time
Not set
Not set
Not set
760ms
Function
Default value
Operator attendant
8001, 8002, 8003,8004;
No
Attendant Mode
Outside (CO) Line Ringing Extension
1
2
3
4
5
7
6
9
8
10
11
12
Operator Extension at DISA mode
8002,8003
Outside( CO ) Line Access Mode
Dial 0 or select CO line
3.5 Outside ( CO ) Line Connection Assignment
Format : * 31 ABCDEF #
ABCDEF = CO line jack need to be connected
Example: Connect CO lines with jack 1,2,3,4 , namely, it is enable CO1,2,3,4.
Operating: 1) Lifts extension 8001 unlock system;
2) Input * 31 1234 #;
3.5.1 Assign CO Line Connection
Description: Assigns which CO line(s) is connected to the system or not.
3.6 Disable CO Lines
Format : * 31 #