PABX 208AC Instruction Manual - page 28
Chapter Three System Program
24
3.25 Clear Extension Numbers Assigned for a Numeric Button
Format : * 140 N #
N = Numeric button = 1 ~ 9
Description: Allows clear extension numbers that assigned for a numeric button ( 1 ~ 9),
suggest to use this program to clear previous setting before program 3.26.
3.26 Assign Extension Numbers for a Numeric Button
Format : * 150 N ABCD #
N = Numeric button = 1 ~ 9
ABCD = Extension number
Description: Allows assign extension numbers belong to numeric buttons(1 ~ 9), here
each button is regarded as an extension group, outside caller can reaches
extension in accordant group by dial digits 1~9, the extensions within
group will ring by turns.
Example: Assign when outside caller dial 1 will reaches group that including 8002, 8003,
8004 and 8005, these extensions will ring by turns.
Operating: 1) Lifts extension 8001 and unlocked;
2) Input * 150 1 8002 # ==> input * 150 1 8003 #;
input * 150 1 8004 # ==> input * 150 1 8005 #;
1. Allows assign maximum of 8 extensions are ring by turns for each numeric
button when outside caller is press a button.
2. Allows assign same or different extension number for each numeric button;
3. When the assigned extension is busy, system will search idle extension start
from next extension, in the case of all extensions are busy, outside caller can
listen a message played informs him that extension is busy, please dial later.
4. When enable function of 3.24, the assigned numeric button digit is not
allowed use as head digit of extension number, otherwise, that extension
number will be invalid.
3.27 Extension is Allowed Access Only Designated CO Line
Format : * 41 MN ABCD #
MN = CO line port number = 01 ~ 16
ABCD = Extension number
Description: The assigned extension is allowed to access only designated CO line to
make outside calls.
Example: Assign extension 8013 is allowed to access only CO line 4.
Operating: 1) Lifts extension 8001 and unlocked;
2) Input * 41 04 8013 # ;
1. Outside call from any CO line can be transferred to this assigned extension,
as well as allows user to pick up any outside call;
2. Only one CO line can be programmed belong to an extension, the last
setting will replace the previous one