PABX 208AC Instruction Manual - page 34
Chapter Three System Program
30
3.43 All Extensions Outgoing Call Class
Format : * 54 M # ( First Class)
* 55 M # ( Second Class)
M is Outgoing Call Class:
M = 0 = Only make intercom call
M = 1 ~ 6 = Restrict to dial CO calls with head-digits in group 1 to 6;
M = 7 ~ 9 = Allows to only dial CO calls with head-digits in group 7 ~9;
Example: Assign first outgoing call class is 3 for all extensions.
Operating: 1) Lifts extension 8001, unlock system;
2) Input * 54 3 #;
3.44 Cancel Extension Outgoing Call Class
Format 1: * 53 ABCD # ( Cancel for certain extension)
Format 2: * 53 # ( Cancel for all extensions )
ABCD = Extension number.
Example: Cancel outgoing call class for extension 8015.
Operating: 1) Lifts extension 8001, unlock system;
2) Input * 53 8015 #;
1. When needs assign same class for the most of extensions, this program
can help you complete setting quickly.
Example: When needs to assign class 1 for extension 8008, 8012, assign
class 7 for extension 8015, 8016 and 8018, other extensions class is 2,
therefore, please assign all extensions class is 2 first, then change class of
extension 8008 and 8012 to class 1, change class of extension 8015, 8016
and 8018 to class 7.
Operating: 1) Lifts extension 8001, unlock system;
2) Input * 54 2 # to assign all extensions class to 2;
3) Input * 518008 1 # => * 518012 1 # => * 518015 7 # => 8016 7 # => 8018 7 #.
The default extension numbers of AC are 8001~8016.
3.45 Restore All Extension Numbers
Format : * 7 000 #
Example: Restore all extension numbers to factory default mode.
Operating: 1) Lifts extension 8001, unlock system;
2) Input * 7 000 #;
3.46 Clear All Extension Numbers
Format : * 71 00 #
Description: It is not allow existing same extension numbers in a system.
Sometimes, user needs to change extension numbers by batch way, the new
extension number may same as original numbers, to avoid conflict, allows
use this program to clear all extension numbers before program 3.49.