Palmer Fixture BluSTORM BOLT Operating Instructions And Parts Manual

Summary of BluSTORM BOLT

  • Page 1

    Palmer fixture company palmer fixture company p.O. Box 10887 green bay, wi 54307 1-800-558-8678 www.Palmerfixture.Com uto a distributed by restroom direct 704 . 937. 2673 www. Restroomdirect .Com.

  • Page 2: Model # Blustorm Bolt

    1 item category operating voltage output warm air volume output warm air temp output air speed sound pressure motor type motor thermal protection heater element heater thermal protection drying time circuit operation sensor range timing protection timing duration cover type cover finish net weight s...

  • Page 3: Hand Dryer

    Installation installation kit included (find in carton) 2 1. Make sure power supply breaker is switched off. Installation must be carried out in accordance with the current edition of the local wiring regulations code having jurisdiction. Installation should be performed only by a qualified electric...

  • Page 4: Hand Dryer

    Operation periodic cleaning of the unit is recommended to ensure optimum performance. Disconnect the electrical supply. Remove the two cover-mounting screws. Remove the cover. Clean all dust lint from the interior of the dryer. Replace the cover. Do not over tighten the screws. Wipe the cover with a...

  • Page 5: Hand Dryer

    4 diagnostics and remedies if the dryer will not run the dryer cycles by itself or runs constantly the dryer runs but air stream is low pressure and/or low velocity ensure that there is no obstruction on or in front of the ir sensor. Clean any dirt or debris off the sensor lens. If problem persists,...

  • Page 6: Hand Dryer

    Assembly diagram operating instructions and parts manual hand dryer surface-mounted ada -compliant hand dr yer 5 1 2 3 4 5 6 7 8 9 10 11 13 12 14 15 16 17 18 19 20 21 22 tools req’d (provided in kit) l-wrench item 23 distributed by restroom direct 704 . 937. 2673 www. Restroomdirect .Com.

  • Page 7: Hand Dryer

    Repair parts list 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 key description qty 1 1 1 1 1 1 1 1 1 1 1 1 4 1 1 1 1 1 1 2 1 1 1 blower housing - upper motor rubber - lower motor 0.67hp@120vac 0.67hp@240vac motor rubber - upper blower housing - lower heater assembly 500w@120vac,28.8Ω ...