  • Page 1

    User manual q-tech q-p019 electric airless spray pump caution! This manual contains important warnings and information please read & keep for future reference issue date 31.05.2014.

  • Page 2: Specifications

    User manual q-tech q-p019 - electric airless spray pump 2 specifications model motor type power input voltage max tip size max flow max pressure dimensions (lxwxh) net weight q-p019 universal 700w 110-120v~ 50-60hz , 220-240v~ 50-60hz 0.021” 1.9 l/min (0.42 gpm) 207 bar (3,000 psi) 36 x 25 x 40 cm 1...

  • Page 3: Save These

    Www.Aristospray.Com 3 general safety rules warning! Read and understand all instructions. Failure to follow all instructions listed below may result in electric shock, fire and / or serious personal injury. The term airless sprayer in all of the warnings listed below refers to your mains-operated (c...

  • Page 4: Service

    User manual q-tech q-p019 - electric airless spray pump 4 d) do not overreach. Keep a proper footing and balance at all times. This enables better control of the airless sprayer in unexpected situations. E) dress properly. Do not wear loose clothing or jewellery. Keep your hair, clothing and gloves ...

  • Page 5: Prevent Static

    Www.Aristospray.Com 5 prevent static sparking fire/explosions vapors created when spraying can be ignited by sparks. To reduce the risk of fire, always locate the sprayer at least 20 feet (6 m.) away from spray area. Do not plug in or unplug any electrical cords in the spray area. Doing so can cause...

  • Page 6: Spray Gun Safety

    User manual q-tech q-p019 - electric airless spray pump 6 • never spray in vicinity of open flame or other sources of ignition. • the spraying area must be at least 20 ft. Away from spray unit. Spray gun safety • always set gun safety lock in the "locked" position when not in use & before servicing ...

  • Page 7: Grounding

    Www.Aristospray.Com 7 • never use a damaged hose, which can result in hose failure or rupture and cause an injection injury or other serious bodily injury or property damage. Before each use, check entire hose for cuts, leaks, abrasions, bulging of the cover, or damage or movement of couplings. If a...

  • Page 8: Assembly:

    User manual q-tech q-p019 - electric airless spray pump 8 assembly: 1. Attach the hose to the pump and tighten with a wrench. 2. Attach the hose to the gun and tighten with a wrench. Operation before beginning: 1. New sprayer your sprayer was factory tested in an oil solution which was left in the p...

  • Page 9: How To Flush

    Www.Aristospray.Com 9 50/50 mixture of mineral spirits and motor oil. Caution: never leave water in the pump for more than about a day. Flush with mineral spirits. How to flush 1. Place the suction tube/suction hose in a flushing bucket filled with clean flushing fluid: either mineral spirits (for o...

  • Page 10: Spraying

    User manual q-tech q-p019 - electric airless spray pump 10 5. Allow the pump to run and watch the fluid discharging from the drain tube. Allow the fluid to discharge until pure material is coming out. 6. Point the gun into the waste bucket, unlock the trigger and hold the trigger open. Then close th...

  • Page 11: To Remove Clogs

    Www.Aristospray.Com 11 have “tails”, which is a pattern with heavy, uneven edges. Keep testing and increasing pressure until a smooth, regular pattern is achieved. If the pressure is at maximum and the pattern is still not ideal, either go to a smaller orifice tip or thin the material. Do not raise ...

  • Page 12: Clogged Flat Tip

    User manual q-tech q-p019 - electric airless spray pump 12 clogged flat tip if you are using a flat tip and the spray tip becomes clogged, relieve pressure from hose by following the "pressure relief procedure." secure gun with the safety latch, take off guard, take out the tip, soak in appropriate ...

  • Page 13: Cleanup

    Www.Aristospray.Com 13 paint, cause overspray, make cutting-in difficult, and decrease sprayer performance. If the tip is the maximum rated size for your sprayer, when it wears, it will exceed the flow rate capacity of the machine. If when using the maximum capacity tip size the pump cannot keep up,...

  • Page 14: Long Term

    User manual q-tech q-p019 - electric airless spray pump 14 13. Without releasing the trigger, transfer the gun to the flushing bucket and allow the flushing fluid to recirculate for 2-3 minutes to make sure that all traces of the material are cleaned out. 14. Turn off the machine and unplug. Open th...

  • Page 15: Daily Maintenance

    Www.Aristospray.Com 15 daily maintenance 1. Keep the displacement pump packing nut lubricated with q-lube piston lubricant at all times. Add about five drops of oil to the top of the pump at the beginning of each day. Then two drops for every hour of spraying. The lubricant helps protect the piston,...

  • Page 16: Motor Maintenance

    User manual q-tech q-p019 - electric airless spray pump 16 6. Replace the packings, glands, o-rings and check balls with the new parts from the rebuild kit. Strictly follow the exact order and orientation. 7. Replace piston and thread on the packing nut. After resistance from the disc springs is fel...

  • Page 17: Troubleshooting

    Www.Aristospray.Com 17 if the replacement of the power supply cord is necessary, this has to be done by the manufacturer or their agent in order to avoid a safety hazard. Warning: all repairs must be entrusted to an authorized service center. Incorrectly performed repairs could lead to injury or dea...

  • Page 18

    User manual q-tech q-p019 - electric airless spray pump 18 oversized tip tip worn to become oversize use correct tip for sprayer relieve pressure and replace tip check problem: motor cannot maintain pressure solution worn tip worn packings filter clogged priming valve leaking suction pipe leaking or...

  • Page 19: Wiring

    Www.Aristospray.Com 19 wiring.

  • Page 20: Qp019 Exploded View

    User manual q-tech q-p019 - electric airless spray pump 20 qp019 exploded view.

  • Page 21

    Www.Aristospray.Com 21.

  • Page 22: Qp019 Parts List

    User manual q-tech q-p019 - electric airless spray pump 22 qp019 parts list q-tech part no. Item description qty qp019-01 1 socket cap screw m5 x 50 3 qp019-02 2 socket cap screw m5 x 25 1 qp019-03 3 socket cap screw m5 x 6 2 qp019-04 4 crank housing 1 qp019-05 5 screw m4 x 8 4 qp019-06 6 cover plat...

  • Page 23: Qp019 Parts List

    Www.Aristospray.Com 23 qp019 parts list q-tech part no. Item description qty qp019-42 42 socket cap screw m5 x 25 4 qp019-43 43 guide cylinder Ø26 x Ø32 x 30 1 qp019-44 44 retaining ring ir-32 1 qp019-45 45 drive piston 1 qp019-46 46 wrist pin-rod Ø10 x 23.5 1 qp019-47 47 packing nut 1 qp00031 48 se...

  • Page 24: Aristospray Uk

    Aristospray uk london granville house wallingford road uxbridge ub8 2rw t 01895 276751 e sales@aristospray.Com dublin 2b stephenstown industrial park balbriggan co. Dublin t 00353 1690 3162 f 00353 1690 3480 e sales@aristospray.Com www.Aristospray.Com.