    Qasair rangehoods are made to suit domestic australian cooking conditions and traditions. Qasair incorporates a system that is efficient over all modern-cooking appliances, while achieving unequalled level of quietness in the kitchen. Now the latest domestic cooking appliances including indoor barbe...

  • Page 3

    Qasair installation instructions 1 important information 2 instructions for models 4 fa / mt / mc / uch / uv / ndch / ech instructions for models 13 h series & pyr instructions for models 17 3f / sf / st / maj / in / sta / smf / fas instructions for models 23 tr ct instructions for models 25 brh / b...

  • Page 4

    Qasair installation instructions 2 condari pty ltd makes over 120 different models of qasair rangehoods plus many specials designed by architects and interior designers. It is important to follow the installation instructions for different models. The following is general advice for the installation...

  • Page 5

    Qasair installation instructions 3 3. Qasair rangehoods must be ducted in duct work equivalent to the outlet of the rangehood ie: the cross sectional area of the rangehood outlet and the duct work must be equal. Do not reduce the duct size or have sharp bends. Enlarge the duct size if the duct is to...

  • Page 6

    Qasair installation instructions 4 installation must be carried out by the procedure outlined. Failure to do so may void the guarantee. Electrical: wiring to the appliance must comply with state and local regulations. Connection to be carried out by a registered electrician. Duct direction (for all ...

  • Page 7

    Qasair installation instructions 5 installation instructions fold away model (fa) 1. The rangehood can now be installed by inserting screws in the three holes provided on each side or to the top or back by drilling your own mounting holes as required. 2. When installed, cover the access holes to the...

  • Page 8

    Qasair installation instructions 6 installation instructions for under cupboard and universal model ( uch, uv, ech & ndch) make cut out to the following sizes. Model hood size base size cut out dimension uch 50f 243 x 480 280 x 500 260 x 485 uch 80h 243 x 780 280 x 800 260 x 785 uch 100h 243 x 980 2...

  • Page 9

    Qasair installation instructions 7 executive range - foldaway fa60f-1 top/backducted fa90f-1 top/backducted fa90f-2 top/backducted executive range - mini trim mt60l-1 top/backducted mt90l-1 top/backducted.

  • Page 10

    Qasair installation instructions 8 executive range - marcel mc10l-2 top/backducted executive range - undercupboard uch50f-1 top/backducted uch80h-1 top/backducted uch80h-2 top/backducted uch100h-2 top/backducted uch120h-2 top/backducted a word of warning for the uch models over induction cooktops. I...

  • Page 11

    Qasair installation instructions 9 executive range - universal uv500f-1 top/backducted uv800f-1 top/backducted uv800f-2 top/backducted uv1000f-2 top/backducted uv1200f-2 top/backducted uv1200f-3 top/backducted uv1500f-3 top/backducted executive range - undermounted ndch60f-1 top/backducted.

  • Page 12

    Qasair installation instructions 10 executive range - undermounted ndch80f-1 top/backducted ndch80f-2 top/backducted executive range - undermounted ndch90f-1 top/backducted ndch90f-2 top/backducted ndch120f-2 top/backducted.

  • Page 13

    Qasair installation instructions 11 executive range - undermounted ndch100f-2 top/backducted.

  • Page 14

    Qasair installation instructions 12 elite range - ech ech600f-1 top/backducted ech800f-1 top/backducted ech900f-1 top/backducted elite range - ech ech800f-2 top/backducted ech900f-2 top/backducted ech1000f-2 top/backducted ech1200f-2 top/backducted.

  • Page 15

    Qasair installation instructions 13 installation must be carried out by the procedure outlined. Failure to do so may void the guarantee. Electrical: wiring to the appliance must comply with state and local regulations. Connection must be carried out by a registered electrician. Recommended fixing po...

  • Page 16

    Qasair installation instructions 14 installation instructions 1. Remove canopy and flue from boxes and check you have correct model and flue. 2. Locate centre point of stove. 3. Use level or plumb line to mark centre up to ceiling. 4. Mark level line for base of canopy 700-800mm above bench 750mm de...

  • Page 17

    Qasair installation instructions 15 heritage range – h 600hl-1 top/backducted 700hl-1 top/backducted 900hl-1 top/backducted • ductoutletdimension topducted240x106mm backduct235x110mm • standardsinglemotorductingwillfit it is recommended that the hood be positioned 700 to 800 above the cooktop. Qasai...

  • Page 18

    Qasair installation instructions 16 heritage range – pyramid pyr900l top/backducted • ductoutletdimension235x110mm • standardsinglemotorductingwillfit.

  • Page 19

    Qasair installation instructions 17 installation must be carried out by the procedure outlined. Failure to do so may void the guarantee. Electrical: wiring to the appliance must comply with state and local regulations. Connection to be carried out by a registered electrician. Flue fitting instructio...

  • Page 20

    Qasair installation instructions 18 federation range – 3 flare 3f900l-2 top/backducted 3f1200l-2 top/backducted • ductoutletdimensions: topducted300x180and400x180 backduct250x250 • standard2motorductingwillfit • atransitionpieceissuppliedtofittothe topoffluetosuit2motorducting 3f1200l-3 top/backduct...

  • Page 21

    Qasair installation instructions 19 federation range – step st900l-1 top/backducted • ductoutletdimension235x110 • standardsinglemotorductingwillfit • topductingmodelcanhaveadl-1drop intothemotor st900l-2 top/backducted st1200l-2 top/backducted • ductoutletdimensions: topduct370x150 backduct250x250 ...

  • Page 22

    Qasair installation instructions 20 gallery range – integra in600l-1 top/backducted in900l-2 top/backducted in1200l-3 top/backducted • ductoutletdimension235x110mm • standardsingle,twinortriplemotor ductingwillfit gallery range – statesman sta900l-2 top/backducted star900l-2 top/backducted sta1200l-...

  • Page 23

    Qasair installation instructions 21 federation range – maitland smf600l-1 top/backducted smf900l-1 top/backducted smf900l-2 top/backducted smf1000l-2 top/backducted • ductoutletdimension235x110 • standardsinglemotorductingwillfit federation range – maitland smf1200l-2 top/backducted smf1500l-2 top/b...

  • Page 24

    Qasair installation instructions 22 shroud the dimensions are shown on the diagram. It is necessary to measure the height to the ceilingoneachsideofthemotorboxsoweget theexactmeasurementtomaketheshroud. We will leave a 2mm gap to allow for any variationintheceilingorhoodinstallation. Imperial range ...

  • Page 25

    Qasair installation instructions 23 the thermidor rangehood is designed to be built into the ceiling. Installation instructions 1. Remove hood from packaging being careful not to touch the stainless steel front. 2. Locate centre of stove and using level or plumb line, mark centre line up to the ceil...

  • Page 26

    Qasair installation instructions 24 gallery range – thermidor trct1000-3 top/backducted trct1200-3 top/backducted trct1500-3 top/backducted • ductoutletdimension235x110mmw • standardtriplemotorductingwillfit trctflange1000 trctflange1200 trctflange1500

  • Page 27

    Qasair installation instructions 25 installation must be carried out by the procedure outlined. Failure to do so may void the guarantee. Electrical: wiring to the appliance must comply with state and local regulations. Connection to be carried out by a registered electrician. Installation instructio...

  • Page 28

    Qasair installation instructions 26 argyle range – benton brh600l-1 top/backducted brh900l-1 top/backducted brh900l-2 top/backducted brh1000l-2 top/backducted brh1200l-2 top/backducted • ductoutletsdimensions: single–duct235x110mm twin–duct250square • standardsinglemotorductingwillfitor 250sqfortwin...

  • Page 29

    Qasair installation instructions 27 installation must be carried out by the procedure outlined. Failure to do so may void the guarantee. Electrical: wiring to the appliance must comply with state and local regulations. Connection to be carried out by a registered electrician. Installation instructio...

  • Page 30

    Qasair installation instructions 28 island hood fixing – for flat, cathedral and exposed beam roofs..

  • Page 31

    Qasair installation instructions 29 imperial range – viscount vis900l-2 islandhood vis1200l-2 islandhood vis1200l-3 islandhood vis1500l-3 islandhood • ductoutletdimensions: twin–duct300x165mm triple–duct400x200mm • standard3motorductingwillfit • transitionpiecesuppliedwithhoodto dl-2ducting federati...

  • Page 32

    Qasair installation instructions 30 imperial range – president pre900l-2 islandhood pre1200l-2 islandhood • ductoutletdimension250x250mm • standard250sqductingwillfit imperial range – president pre1500l-2 islandhood pre1500l-3 islandhood pre1800l-3 islandhood • ductoutletdimension250x250mm • standar...

  • Page 33

    Qasair installation instructions 31 argyle range – albany d400l-1 islandhood • ductoutletdimension110x235mm • standarddl-1ductingwillfit argyle range – albany d500l-2 islandhood • ductoutletdimension250square.

  • Page 34

    Qasair installation instructions 32 argyle range – winton sq420l-2 islandhood • ductoutletdimension250sq • standard250mmductingwillfit argyle range – burdett bur900l-2 islandhood bur1000l-2 islandhood bur1200l-2 islandhood bur1200l-3 islandhood bur1500l-2 islandhood bur1500l-3 islandhood • ductoutle...

  • Page 35

    Qasair installation instructions 33 gallery range – maddison ma2000-2500l-4 islandhood ma2500-3000l-4 islandhood • ductoutletdimension250sq • standardfourmotorductingwillfitor imperial range – hamilton bur900l-2 islandhood bur1200l-2 islandhood • ductoutletsdimension250square • standardsinglemotordu...

  • Page 36

    Qasair installation instructions 34 argyle range – fremont fprl-2 islandhood • ductoutletdimension250sq • standard250mmductingwillfit.

  • Page 37

    Qasair installation instructions 35 special rangehoods are hoods made to specific designs and not covered by the instructions in this booklet for standard hoods, although the basic rules will still apply. Generally, special rangehoods are either wall or ceiling mounted and therefore are installed in...

  • Page 38

    Qasair installation instructions 36 lamp replacement and filter care qasair rangehoods are fitted with low voltage halogen lights which give a very clear, bright light. These become very hot if left on for a long period and can burn out. Please switch off after use. 1. Turn off power at power point....

  • Page 39

    Qasair installation instructions 37 101. Dl-1ductlength1200mm dl-1cductlength(coloured) 103. Hb-1-45horizontalbend45º 102. Hb-1horizontalbend90º 104. Bd/wv-h-1backdraftwallventhorizontal ducting pieces single motor twin motor triple motor the following pages show all the ducting pieces available. Th...

  • Page 40

    Qasair installation instructions 38 105. Bd/wv-h-1mgsbackdraftwallvent horizontalmarinegradestainlesssteel 108. Bd/wv-v-1backdraftwallventvertical 111. Tt-1twistedtransition 106. Vb-1verticalbend90º 109. Bd/wv-v-1mgsbackdraftwallvent verticalmarinegradestainlesssteel 112. Dle-dlefluejoiner 107. Vb-1...

  • Page 41

    Qasair installation instructions 39 ‹‹ single m otor 117. Dr-200cbductlength1200mm colourbond 120. Bd-6/7/9-wv-r/rrearregistarkit 118. Dr-200/45roundbend45º 121. As-20backdraftshutter 119. Dr-200/90roundbend90º 122. Ch-200chairman'shat200ø 123. Ch-200cbchairman'shatcolourbond 126. Bd/sq-rc200backdra...

  • Page 42

    Qasair installation instructions 40 ‹‹ single m otor 132. Wvc-v-1wallventcoververtical 135. Ev/dl-1eaveventsuitdl-1 138. Hb-195/45horizontalbend45º 133. Wvc-v-1mgswallventcoververtical marinegradestainlesssteel 136. Dl-195ductlength 139. Bd/wv-195sqbackdraftwallvent square 134. 6/7/900h-scspigotcap ...

  • Page 43

    Qasair installation instructions 41 ‹‹ single m otor 141. Wvc-6/7/9h-r/rwallventcover 142. Wvc-195sqwallventcover 143. Rcp-200s/sroofcap200ø stainlesssteel 144. Rc-200s/sroofcowl200ø stainlesssteel 145. Rc-200zincroofcowl200øzincalumne 146. Rc-1s/sroofcowlsinglemotor stainlesssteel.

  • Page 44

    Qasair installation instructions 42 201. Tmttwinmotortransition 204. Hb-2/45horizontalbend45º 207. Vb-2verticalbend90º 202. Dl-2ductlength1200mm 205. Bd/wv-h-2backdraftwallvent 208. Vb-2/45verticalbend45º 203. Hb-2horizontalbend90º 206. Bd/wv-h-2mgsbackdraftwallvent marinegradestainlesssteel 209. Bd...

  • Page 45

    Qasair installation instructions 43 ‹‹ twin m otor 213. Bd10/12/15-wv-r/rrearregisterkit 216. Dr-300ductlength300ø1200mm 214. Tmt-300transsitionto300ø 217. Dr-300cbductlength300ø1200mm colourbond 215. Tr-2transitionfromdl-2to300ø 218. Dr-300/45roundbend45º 219. Dr-300/90roundbend90º 222. Tmt-250twin...

  • Page 46

    Qasair installation instructions 44 225. Hb-250/45horizontalbend45º 226. Tmt-250/90ductdeflector250sq leftorright 227. Bd/wv-250sqbackdraftwall250sq ‹‹ twin m otor 228. Bd/wv-250sqmgsbackdraftwall 250sqmarinegradestainlesssteel 231. Ch-300chairman'shat300º 234. Bd/rc-250sqbackdraftroofcowl250sq 229....

  • Page 47

    Qasair installation instructions 45 237. Cf-3f900-2ceilingflange3f900-2 240. Cf-4f1200-2ceilingflange4f1200-2 243. Wvc-v-2wallventcoververtical 238. Cf-3f1200-2ceilingflange3f1200-2 241. Wvc-h-2wallventcoverhorizontal 244. Wvc-v-2mgswallventcoververtical marinegradestainlesssteel 239. Cf-4f900-2ceil...

  • Page 48

    Qasair installation instructions 46 ‹‹ twin m otor 255. Cf3f-1500-2ceilingflange3f-1500-2 252. Bd/m-250sqbackdraftdamper250sq 249. Dd-2h-l/rductdirectorhorizontal leftorright 253. As-25backdraftshutter 250. Dd-2v-l/rductdirectorvertical leftorright 254. Bd/wvc-sbsbackdraftwallventcover 251. Ev/dl-2e...

  • Page 49

    Qasair installation instructions 47 306. Vb-3/45verticalbend45º 309. Tr-3transitionto350ø 308. Tmt-400x200/350transitionfromdl-3 to350ø 307. Tt-3twistedtransition 304. Hb-3/45horizontalbend45º 305. Vb-3verticalbend90º 301. 3mt-dl-3threemotortransition 302. Dl-3ductlength1200mm 303. Hb-3horizontalben...

  • Page 50

    Qasair installation instructions 48 318. Ch-350chairman'shat350ø 317. Bd/sq-rc350mgsbackdraftroofcowl 350ømarinegradestainlesssteel 313. Dr-350/90bend90ø350ø 314. Bd/rc-3backdraftroofcowl 315. Bd/rc-3mgsbackdraftroofcowl marinegradestainlesssteel 316. Bd/sq-rc350backdraftroofcowl350ø ‹‹ triple m oto...

  • Page 51

    Qasair installation instructions 49 327. Wvc-v-3mgswallventcoververtical marinegradestainlesssteel 326. Wvc-v-3wallventcoververtical 325. Wvc-h-3mgswallventcoverhorizontal marinegradestainlesssteel ‹‹ triple m otor 330. As-35backdraftshutter 329. Dd-3v-rductdirectorverticalright 328. Dd-3v-lductdire...

  • Page 52

    Qasair installation instructions 50 1. Fa60-1b 2. Fa90-1t installation ideas 3. Fa60-1t.

  • Page 53

    Qasair installation instructions 51 5. Fa60-1t 4. Fa60-1t 6. Fa60-1t/60-1b 7. Fa90-2t 8. Fa90-2t 9. Fa90-2t.

  • Page 54

    Qasair installation instructions 52 12. Fa90-2t 11. Fa90-2t 14. 600h-t 13. 600h-t/700h-t/900h-t 15. Uch50-1t 10. Fa90-2b.

  • Page 55

    Qasair installation instructions 53 16. Uch80-1t 18. Uch80-2t 17. Uch50-1t 19. 1200h-t 20. Uv800-2t 21. Uv1000-2t.

  • Page 56

    Qasair installation instructions 54 22. 3f900-2t/1200-2t 24. Uv800-1t 23. Uv500-1t 26. Uv1200-2b 25. Uch80-1t/uv1000-2t.

  • Page 57

    Qasair installation instructions 55 there are some exclusions from the condari pty ltd guarantee. The guarantee is printed at the back of brochure. Qasair rangehoods are designed to be used over all domestic cookware available in australia. Qasair rangehoods are not to be used over barbecues approve...

  • Page 58

    Qasair installation instructions 56 notes _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ...

  • Page 59

    Qasair installation instructions 57 notes _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ...

  • Page 60

    Qasair installation instructions 58 notes _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ ...

  • Page 61: S Ta N D A R D

    S ta n d a r d warranty condari p/l appliance guarantee the benefits conferred by this warranty are in addition to all other rights and remedies in respect of the product which the consumer has under the trade practices act and similar state and territory laws. Condari p/l in melbourne (and by their...

  • Page 62

    Qasair rangehoods made in ringwood 3134 qasair reserves the right to change specification without notice. ® is a registered trade mark. Distributed in australia by condari pty ltd tel: 1300 360 563 vic tel: +61 3 9482 7088 fax: +61 3 9482 7011 email: sales@qasair.Com.Au website: www.Qasair.Com.Au yo...