QD Pi HSC505-32 LCD User's Information Manual

Summary of Pi HSC505-32 LCD

  • Page 1

    Hsc505-e 8-32 zone lcd home security controller - user manual ________________________________________________________________________________________________ page 1 this document and product are copyrighted and all rights are reserved. Pi hsc505-32 lcd home security controller user's information gu...

  • Page 2

    Hsc505-e 8-32 zone lcd home security controller - user manual ________________________________________________________________________________________________ page 2 this document and product are copyrighted and all rights are reserved. Congratulations on your purchase of the pi hsc505-32. The south...

  • Page 3: Error Conditions:

    Hsc505-e 8-32 zone lcd home security controller - user manual ________________________________________________________________________________________________ page 3 this document and product are copyrighted and all rights are reserved. Home - the system or partition is armed with certain zones bein...

  • Page 4

    Hsc505-e 8-32 zone lcd home security controller - user manual ________________________________________________________________________________________________ page 4 this document and product are copyrighted and all rights are reserved. Low battery - the on board battery is not charged to capacity a...

  • Page 5: User Programmable Functions:

    Hsc505-e 8-32 zone lcd home security controller - user manual ________________________________________________________________________________________________ page 5 this document and product are copyrighted and all rights are reserved. Keypad displays ”enter zone number 00”. Enter 2-digit zone numb...

  • Page 6

    Hsc505-e 8-32 zone lcd home security controller - user manual ________________________________________________________________________________________________ page 6 this document and product are copyrighted and all rights are reserved. Enter 4-digit pin number _______________ or the bypass key to d...

  • Page 7

    Hsc505-e 8-32 zone lcd home security controller - user manual ________________________________________________________________________________________________ page 7 this document and product are copyrighted and all rights are reserved. Enable 30 second siren delay when armed in the home mode: enter...

  • Page 8

    Hsc505-e 8-32 zone lcd home security controller - user manual ________________________________________________________________________________________________ page 8 this document and product are copyrighted and all rights are reserved. Entering a codex remote transmitter enter user programming. Sel...

  • Page 9: Pi Hsc505 - E

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 1 this document and product are copyrighted and all rights are reserved. Qd dynamics (pty) ltd kyalami business park kyalami, midrand 1685 po ...

  • Page 10

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 2 this document and product are copyrighted and all rights are reserved. Table of contents introduction ………………………………………………………………………………………. 3 t...

  • Page 11: Introduction:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 3 this document and product are copyrighted and all rights are reserved. Introduction: the pi hsc505-32 is a south african designed and manufa...

  • Page 12

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 4 this document and product are copyrighted and all rights are reserved. Congratulations on your purchase of the pi hsc505-e. The south africa...

  • Page 13

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 5 this document and product are copyrighted and all rights are reserved. Input - a terminal on the control panel that a detector is connected ...

  • Page 14: Motherboard Layout:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 6 this document and product are copyrighted and all rights are reserved. Motherboard layout: ac……………….Ac input maximum 16.5v 40va (earth) .......

  • Page 15: Expander Board Layout:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 7 this document and product are copyrighted and all rights are reserved. The siren tamper will cause an error to be displayed on all keypads a...

  • Page 16: Keypad Wiring:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 8 this document and product are copyrighted and all rights are reserved. Only normally closed switches may be used in this configuration. The ...

  • Page 17: Remote Expander Board

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 9 this document and product are copyrighted and all rights are reserved. Remote expander board – qe1004 the remote expander is an 8 zone input...

  • Page 18: Bus Line Codex Receiver.

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 10 this document and product are copyrighted and all rights are reserved. Bus line codex receiver. By using the bus line receiver, the 505 –e ...

  • Page 19

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 11 this document and product are copyrighted and all rights are reserved. Qe920 wireless expansion module the qe920 is a wireless 8 zone bus e...

  • Page 20: Installation Instructions

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 12 this document and product are copyrighted and all rights are reserved. Installation instructions 1) connect the qe920 to the hsc 505e bus l...

  • Page 21

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 13 this document and product are copyrighted and all rights are reserved. Note- a wireless detector can only be programmed into a single locat...

  • Page 22

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 14 this document and product are copyrighted and all rights are reserved. Testing detector tamper conditions 1) press the function button unti...

  • Page 23: First Time Installation:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 15 this document and product are copyrighted and all rights are reserved. First time installation: 1. Default the control panel by placing a j...

  • Page 24: Programming:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 16 this document and product are copyrighted and all rights are reserved. Programming: enter programming mode: when entering into the installe...

  • Page 25: Zone Programming:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 17 this document and product are copyrighted and all rights are reserved. Zone programming: controlled zones: entry/exit - this zone type is t...

  • Page 26

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 18 this document and product are copyrighted and all rights are reserved. Question 1 to 34 location 1 = zone type, location 2 = partition numb...

  • Page 27

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 19 this document and product are copyrighted and all rights are reserved. Keypad partition assignment: each keypad on the system must be assig...

  • Page 28: Home Zone Enabled:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 20 this document and product are copyrighted and all rights are reserved. Home zone enabled: question 38 and 39 any zone assigned as a home zo...

  • Page 29: Home Zone Enable:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 21 this document and product are copyrighted and all rights are reserved. Home zone enable: question 39 location 1 = home zones 17 to 20, loca...

  • Page 30: Zone Tamper Enable:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 22 this document and product are copyrighted and all rights are reserved. Zone tamper enable: question 40 zones 1 to 16 , (zones 17 to 32 are ...

  • Page 31: Bypass Enable:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 23 this document and product are copyrighted and all rights are reserved. Bypass enable: question 41 bypass enable zones 1 to 16. Location 1 =...

  • Page 32: Bypass Enable:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 24 this document and product are copyrighted and all rights are reserved. Bypass enable: question 42 bypass enable zones 17 to 32. Location 1 ...

  • Page 33: Auto Arm Modes:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 25 this document and product are copyrighted and all rights are reserved. Auto arm modes: question 43 location 1 = auto arm mode for partition...

  • Page 34: Timers:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 26 this document and product are copyrighted and all rights are reserved. Timers: entry question 48 location 1 = entry delay partition 1, loca...

  • Page 35

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 27 this document and product are copyrighted and all rights are reserved. Question 50 zone tamper 17 to 32 location 1 = zones 17 to 20, locati...

  • Page 36

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 28 this document and product are copyrighted and all rights are reserved. Question 52 location 1 = auto test delay, location 2 = communicator ...

  • Page 37

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 29 this document and product are copyrighted and all rights are reserved. Question 52 location 3: ac fail delay sets the delay time between a ...

  • Page 38: System Functions:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 30 this document and product are copyrighted and all rights are reserved. System functions: quick command functions question 53 location 1 = f...

  • Page 39

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 31 this document and product are copyrighted and all rights are reserved. Question 53 location 3: arm when faulted allows arming when an entry...

  • Page 40

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 32 this document and product are copyrighted and all rights are reserved. Question 55 location 1 = siren trip count, location 2 = panic key mo...

  • Page 41: Communication Options:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 33 this document and product are copyrighted and all rights are reserved. Question 55 location 4: dual reporting dual reporting enabled will c...

  • Page 42

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 34 this document and product are copyrighted and all rights are reserved. Question 56 location 3: ring count select the number of rings that t...

  • Page 43: Remote Or Onboard Expansion

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 35 this document and product are copyrighted and all rights are reserved. Remote or onboard expansion question 58 selects zones 9 to 16 of bei...

  • Page 44: Keypad Zones:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 36 this document and product are copyrighted and all rights are reserved. Keypad zones: question 60 location 1 = reserved, location 2 = reserv...

  • Page 45

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 37 this document and product are copyrighted and all rights are reserved. Question 61 not used. Question 62 not used. Reporting codes: questio...

  • Page 46: Account Numbers:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 38 this document and product are copyrighted and all rights are reserved. Question 72 location 1 = keypad tamper digit 1. Location 2 = keypad ...

  • Page 47: Trigger Timers

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 39 this document and product are copyrighted and all rights are reserved. Question 90 = secondary telephone number digits 9 to 12. Question 91...

  • Page 48: Trigger Default Polarity:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 40 this document and product are copyrighted and all rights are reserved. Question 103. Location 1 = trigger 13 timer, location 2 = trigger 14...

  • Page 49

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 41 this document and product are copyrighted and all rights are reserved. Location 2: (preset the +12v state of the outputs). Presets the defa...

  • Page 50

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 42 this document and product are copyrighted and all rights are reserved. Location 4: (preset the +12v state of the outputs). Presets the defa...

  • Page 51

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 43 this document and product are copyrighted and all rights are reserved. Location 2: (preset the +12v state of the outputs). Presets the defa...

  • Page 52: Codex Remote Transmitters:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 44 this document and product are copyrighted and all rights are reserved. Location 4: (preset the +12v state of the outputs). Presets the defa...

  • Page 53

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 45 this document and product are copyrighted and all rights are reserved. Question 111 remote 2 location 1 = button 1, location 2 = button 2 l...

  • Page 54: Triggers:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 46 this document and product are copyrighted and all rights are reserved. Question 119 remote 10 location 1 = button 1, location 2 = button 2 ...

  • Page 55

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 47 this document and product are copyrighted and all rights are reserved. Trigger events system: trigger event event # mains fail 065 mains re...

  • Page 56

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 48 this document and product are copyrighted and all rights are reserved. Codex remote transmitter button 1 button 2 button 3 button 4 remote ...

  • Page 57

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 49 this document and product are copyrighted and all rights are reserved. Ademco point id reporting codes: burglary types 24-hour description ...

  • Page 58

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 50 this document and product are copyrighted and all rights are reserved. Hsc 505-e programming work sheet installer code is changed in questi...

  • Page 59

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 51 this document and product are copyrighted and all rights are reserved. Question description zone type partition # rep code d1 rep code d2 d...

  • Page 60

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 52 this document and product are copyrighted and all rights are reserved. Question description 1 to 4 5 to 8 9 to 12 13 to 16 default 40 zone ...

  • Page 61

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 53 this document and product are copyrighted and all rights are reserved. Question description reserved reserved k/p zones k/p zones default 6...

  • Page 62

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 54 this document and product are copyrighted and all rights are reserved. Question second acc digit 1 digit 2 digit 3 digit 4 default 80 parti...

  • Page 63

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 55 this document and product are copyrighted and all rights are reserved. Question description trigger 1 trigger 2 trigger 3 trigger 4 default...

  • Page 64: Trigger Outputs:

    Hsc505 - e 8-32 zone lcd home security controller - installation manual ________________________________________________________________________________ page 56 this document and product are copyrighted and all rights are reserved. Question 120 to 127 are reserved for future use trigger outputs: tri...