Quinnamp SDQ1b Owner's Manual - page 5
IEC Module – contains the main power switch, power cord inlet connector and the fuse drawer. To
access the fuse(s) use a small flat blade screwdriver in the notch at the bottom of the power cord
inlet connector, the drawer is then pulled outward. The IEC Module can accept both large (3AG
footprint) or smaller European (5mm X 20mm) fuses.
A time delay variety (SLO-BLO) is recommended. A 5 amp fuse is recommended for domestic use
(110 – 125 VAC) and 2.5 amps should be used for Export use
(220 – 240 VAC). The fuse drawer can be rotated on some export models for voltage selection,
make sure the correct value fuse is located on the same side of the fuse drawer as the desired
selection arrow. Line up the appropriate arrow on the fuse drawer with the arrow on the bottom right
of the module for the proper VAC selection.
Standby Switch:
Standby- This switch allows the tubes to warm up before applying operating power to the amplifier.
Wait 45 seconds to 1 minute after powering on the mains before moving it up to the operate position.
For improved tube life and performance do not leave the amplifier in Standby position for longer than
20 minutes (Best to leave it in operate mode during performance intermissions).
5